R&S FSG Remote Control – Description of Commands SENSe Subsystem performs a measurement sequence with the following settings: Step Freq. [MHz] Ref Level RF Att el Att Filter type RBW VBW Meas Time TRG Level (reserved) 1 935.2 -20 dBm 10 dB OFF Normal 1 MHz 3 MHz 434 us 0 2 935.4 -20 dBm 10 dB 10dB Channel 30 kHz 100 kHz 434 us 0 3 935.6 -20 dBm 10 dB 20dB Channel 30 kHz 100 kHz 434 us 0 "SENSe:LIST:POWer? 935.2MHz,-20dBm,10dB,OFF,NORM,1MHz,3MHz,434us,0, 935.4MHz,-20dBm,10dB,10dB,CFIL,30kHz,100kHz,434us,0, 935.6MHz,-20dBm,10dB,20dB,CFIL,30kHz,100kHz,434us,0" performs the same measurement and returns the result list immediately after the last frequency point. • The measurement is performed in the time domain and therefore the span is set to 0 Hz. If the time domain is abandoned, the function is automatically switched off. • The measurement is not compatible with other measurements, especially as far as marker, adjacent channel power measurement or statistics are concerned. The corresponding commands thus automatically deactivate the function. • The function is only available in remote control. It is deactivated when switching the instrument back to LOCAL. Characteristics: *RST value: -SCPI: device-specific Mode: A [SENSe<1|2>:]LIST:POWer:SET <PEAK meas>,<RMS meas>,<AVG meas>,<trigger mode>,<trigger slope>,<trigger offset>, <gate length> This command defines the constant settings for the list during multiple power measurement. Parameters <PEAK meas>, <RMS meas> and <AVG meas> define, which measurements are to be performed at the same time at the frequency point. Correspondingly, one, two or three results per frequency point are returned for the SENS:LIST:POW? command. If all three parameters are set to OFF, the command generates an execution error. Parameter: <PEAK meas>: ON activates the measurement of the peak power (peak detector). OFF deactivates the measurement of the peak power. <RMS meas>: ON activates the measurement of the RMS power (RMS detector). OFF deactivates the measurement of the RMS power. <AVG meas>: ON activates the measurement of the average power (average detector). OFF deactivates the measurement of the average power. <trigger mode>: Selection of the trigger source used for the list measurement. Possible values: IMMediate | VIDeo | EXTernal | IFPower <trigger slope>: Used trigger slope. Possible values: POSitive | NEGative <trigger offset>: Offset between the detection of the trigger signal and the start of the measurement at the next frequency point. Range of values: 0 s, 125 ns to 100s 6.172 Operating Manual 1309.0090.12 - 05
Related documents
R&S®FSQ User Manual - Rohde & Schwarz Colombia
FSQ Operating Manual English FW 4.55
R&S®ESPI Operating Manual
Note - MATsolutions
R&S®FSU Operating Manual
R&S®FSP Operating Manual
HP 8970B Option 020 Service Manual Supplement
R&S
R&S FSQ-K10x EUTRA/LTE UL Measurement
R&S FSE Series Operation Vol 2
R&S ESR EMI Test Receiver - Rohde & Schwarz Middle East and
Operating Manual FSP Vol. 2