Download Chapter B CONTRACT DOCUMENTS
Transcript
BOLLARDS - Item No. Special Provision No. 599S27 1. September 2007 SCOPE This Special Provision covers the requirements for the installation of bollards. 2. REFERENCES This Special Provision refers to the following standards, specifications or publications: Ontario Provincial Standard Specifications, Construction: OPSS 603 Installation of Ducts Ontario Provincial Standard Specifications, Material: OPSS 1350 Concrete – Materials and Production 3. DEFINITIONS – Not Used 4. DESIGN AND SUBMISSION REQUIREMENTS – Not Used 5. MATERIALS 5.1 Pipe Galvanized steel pipe shall meet the requirements of OPSS 603 for steel conduit. 5.2 Concrete Concrete shall meet the requirements of OPSS 1350, 30 MPa class. 5.3 Reflective Tape Reflective tape shall be non-metallic 6-inch Engineering Grade (Type I) Safety Reflective Tape in yellow colour. 6. EQUIPMENT – Not Used 7. CONSTRUCTION Bollards shall be installed plumb and at the same height as indicated in the Contract Drawings and marked with a reflective tape following the placement. Three tape stripes shall be placed starting at the top with 100mm separation between each stripe. 7.1 September 2007 Quality Control Pg. 1 of 2 SSP599S27