Micro-Tech 3106 A damping factor can also be selected for each current channel. This damping only affects the current output, not the displayed flow rate, which has a separate damping factor, selectable in Main Menu 2, Display. Scroll DOWN and the I/O DEF SCROLL 1C screen displays. - I/O DEF SCROLL 1C Current out damping Password: Operator #1: 2 sec ENTER NEXT Default: Min: 2 sec 0 sec Max: 400 sec 2. Define Analog Inputs If the 2-inputs/2 outputs analog board is installed, the following screens are displayed. Analog inputs can be used for measuring the moisture of the material. Moisture compensation is performed on the process material flow, and affects both rate and totals. Only during material calibration with material is moisture compensation suspended, so that the totalized quantity can be directly compared to the weight obtained on a static scale. The moisture compensation is executed before adding to totals. Press the CHOICE soft key to scroll selections. Press ENTER to confirm your selection. Scroll DOWN and the I/O DEF SCROLL 2 screen displays. - I/O DEF SCROLL 2 Analog input #1 def. Password: Service #1: > Off < CHOICE ENTER CALIB Default: Selections: OFF OFF, MOISTURE Scroll DOWN and the I/O DEF SCROLL 3 screen displays. - I/O DEF SCROLL 3 Analog input #2 def. Password: Service #2: > Off < CHOICE ENTER CALIB Default: Selections: REC 4187 OFF OFF, MOISTURE B-27