Download Model 1005
Transcript
Testing Resistance, Diode, and Continuity Testing Frequency, Duty Cycle, or Pulse Width Use this menu option to test resistance, diode forward voltage, and the continuity of wiring and connections. Connect the test lead tip and test lead ground across the object to be tested. GRAPHING MULTIMETER GMM OHM FREQUENCY CONTINUTY OPEN CLOSE OHM Press to measure resistance. DUTY CYCLE PULSE WIDTH Press to test diodes. Press to test continuity of wiring and connections. If you select OPEN, the instrument beeps when the tested connection is open. If you select CLOSE, it beeps when the tested connection is closed. OFL is displayed when the resistance is outside the instrument’s maximum range. This occurs when the resistance of the sensor is too high or the connection to the sensor is interrupted or open. GMM FREQUENCY GMM DUTY CYCLE % ms Hz GMM PULSE WIDTH % ms Hz Press to test the signal frequency in Hz. P ress t o test the dut y cycle of the signal. If you select , the duty cycle of the negative-going pulse is displayed. If you select , the duty cycle of the positive-going pulse is displayed. To test a diode, the instrument sends a small current through the diode to test the voltage across it. Depending on the type of diode, this voltage should be in the range from 300 to 600 mV. A diode that has an internal short will display about 0 V. OFL is displayed when the diode is defective or when it is connected in reverse. If you are not certain about the polarity of the diode, try the reverse connection. If this also displays OFL, the diode is defective. A good diode must display OFL when connected in reverse. % ms Hz Press to test the pulse width of the signal. If you select , the width of the negative-going pulse is displayed. If you select , the width of the positive-going pulse is displayed. Testing Secondary Ignition Peak Volts, Burn Volts, and Burn Time Measuring RPM The instrument automatically scales and displays the waveform on the screen. Connect the Inductive Pickup to the COM/TRIGGER input terminals and clamp the pickup probe on the spark plug wire close to the spark plug. GRAPHING MULTIMETER GMM RPM Press to adjust the built-in 4 step trigger levels. Default is Level 2. Press to decrease. RPM TRIG 2 IGNITION PEAK VOLTS n 1 720 DEFAULT SETUP REPEAT TEST IGNITION BURN VOLTS Press to start plotting a new graph as new samples are acquired. IGNITION BURN TIME Press to restore the default value settings stored in VEHICLE DATA. Press to increase. GMM IGNITION PEAK VOLTS INVERT OFF REPEAT TEST MAX/MIN RESET GMM IGNITION BURN VOLTS INVERT OFF REPEAT TEST MAX/MIN RESET GMM IGNITION BURN TIME INVERT OFF REPEAT TEST MAX/MIN RESET and keys are used to set the number of Spark Signal Pulses to the instrument per 720 (two crank shaft revolutions). n = 1, 2, 3, 4, 5, 6, 8, 10, or 12 Press to invert the displayed ignition waveform. 5-10 5-11