Download D067/D068/D069/D072 Service Manual Appendix
Transcript
System Service Mode (Basic: D067/D072) 2927* 2927 1 2928 ID Sensor Control [0 = No / 1 = Yes] Determines whether the ID sensor signal is referenced or not for the toner density control. Keep the default value in usual operations. Toner End Clear Clears the following messages and counters without supplying the toner: 2928 1 Toner near end message Toner end message Toner near end counter Toner end counter Do not use this SP in usual operations. When the toner in the development unit is abnormally insufficient, the drum may attract the toner carrier to its surface. The toner carrier damages the drum surface.. Vref Limits Adjust the upper or lower Vref limit. 2929 1 Upper [0.50 to 3.50 / 3.20 / 0.01V/step] DFU 2929 2 Lower [0.50 to 3.50 / 0.70 / 0.01V/step] DFU 2994* ID Detect Temp [30 to 90 / 30 / 1 °C/step] Adjusts the temperature threshold. The ID sensor signal is not referenced 2994 1 when the fusing temperature is at the specified level or higher while the copier is recovering or starting up. SM Appendix 5-151 D067/D068/D069/D072 Appendix: SP Mode Tables 2929*