WARNING CHIME/WAGON AND HARDTOP MODELS
Trouble Diagnoses/Except for Europe, South
Africa and with Theft Warning System Models
(Cont’d)
DIAGNOSTIC PROCEDURE 2
(Key switch input signal check)
SEL354Y
CHECK KEY SWITCH INPUT SIGNAL.
Check voltage between combination meter
harness connector M141 terminal q
19 (BR)
and ground.
Condition of key switch
Voltage [V]
Key is inserted.
Approx. 12
Key is withdrawn.
0
OK
H
Go to DIAGNOSTIC PROCEDURE 3.
EL-172
NG
E
Check the following.
I Key switch
Refer to “Electrical Components Inspection” (EL177).
I 7.5A fuse [No. 24 ,
located in fuse block
(J/B)]
I Harness for open or
short between key switch
and fuse
I Harness for open or
short between combination meter and key
switch