Theory of Operations though the more advanced control features (active exhalation valve control) are not functional. Note: During Mix and Inspiratory BUV, gas supply to installed options is disabled. Entry into BUV is logged in the alarm log and system diagnostic log, and the status display provides an indicator that the ventilator is in BUV and which subsystem is affected. When in BUV, a high priority alarm is annunciated, and the GUI displays an alarm banner indicating BUV, blanks patient data, and a displays a pressure waveform. If the ventilator cannot provide any degree of reliable ventilatory support and fault monitoring, then the ventilator alarms and enters the safety valve open (SVO) emergency state. During SVO, the ventilator de-energizes the safety, expiratory, and inspiratory valves, annunciates a high-priority alarm, and turns on the SVO indicator. During SVO, a patient can spontaneously inspire room air (if able to do so) and exhale. Check valves on the inspiratory and expiratory sides minimize rebreathing of exhaled gas during SVO. During SVO the ventilator • Displays the elapsed time without ventilatory support • Does not display patient data (including waveforms) • Does not detect patient circuit occlusion or disconnect conditions Visible indicators on the ventilator's GUI and status display illuminate when the ventilator is in the SVO state. Other safeguards built into the ventilator include a one-way valve (check valve) in the inspiratory pneumatic circuit allowing the patient to inhale through the safety valve with limited resistance. This check valve also limits exhaled flow from entering the inspiratory limb to reduce the possibility of re-breathing exhaled CO2 gas. 10.17 Power On Self Test (POST) Every time the ventilator is powered on or resets and at the beginning of Short Self Test (SST) and Extended Self Test (EST) it performs Power On Self Test (POST). POST checks the integrity of the GUI and Breath Delivery subsystems and communication channels without operator intervention and takes approximately twelve(12) s to complete. 10-76 Operator’s Manual
Related documents
Puritan Bennett 840 - Innovations and Solutions for Infusion
Puritan Bennett
Covidien
Maison des écrivains : mode d`emploi à la lumière d`une
Lowrance electronic X-40 User's Manual
Puritan Bennett
Brochure
Puritan Bennett
PROBADOR DE TIERRAS TIPO GANCHO MODELO 4200
840 Ventilator System
Ground Clamp Resistance Meter
O.c 0146 840 datasheet