Theory of Operation Ver1.0 Sep.2006 Original reading timing • When AE/ACS is not set, the exposure unit movement is the same in the platen mode and the DF. • When AE/ACS is set, the exposure unit movement differs between the platen mode and the DF mode. bizhub PRO C6500 E. 7. SCANNER SECTION (1) When AE/ACS is not set [1] [2] [3] [4] [5] [6] [7] a03ut2c020ca [1] Home position [5] White correction (Second time) [2] Scanner home sensor (PS1) [6] Exposure scan (270 mm/s) [3] Platen APS position [7] Home position search [4] White correction (First time) (2) When AE/ACE is set (Platen mode) [1] [2] [3] [4] [5] [6] [7] [8] a03ut2c021ca [1] Home position [5] White correction (Second time) [2] PS1 [6] AE/ACS scan (409 mm/s) [3] Platen APS position [7] Exposure scan (270 mm/s) [4] White correction (First time) [8] Home position search 27