Test Operation 7) Cycle status Ŷ Inspection item : Cycle status of Outdoor Unit. Ŷ Error code: None (The resulting report "Undetermined") Ŷ Determine the Cycle status of the each Outdoor Unit. Ŷ If the judgment of Cycle status is "Undetermined" : Checking in accordance with the following order. Auto Trial Operation results, is Valve and Pressure sensor normal? No Check the corresponding Valve /Sensor and Compressor. Yes Is Discharge Temperature sensor of corresponding Outdoor Unit normal? No Inspection and measures of Discharge Temperature sensor. (Assembly status, connector, resistance, etc.) [Discharge Temperature sensor resistance value] Temperature(℃) Yes When Auto Trial Operation, does maintain Thermo On status of Indoor Unit? No Indoor ventilation Yes Is refrigerant in the system properly? ※ Resistance measurement method After separating the Temperature sensor connector from the PCB, measure the resistance value between the two terminals. No Adjusts the refrigerant (Addition / Emitted) Resistance(KΩ) 130 8.9 120 11.2 100 18.5 80 32.0 60 59.0 25 200.0 20 242.0 10 362.0 0 553.0 Yes Complete 9-10 Samsung Electronics