Download MAINTENANCE INTERVALS - Safety
Transcript
110 Maintenance Section Cab Filter (Recirculation) - Clean/Inspect/Replace i01251123 Cab Filter (Recirculation) Clean/Inspect/Replace (If Equipped) i01521730 Coolant Sample (DEAC) Obtain SMCS Code: 1395-554 SMCS Code: 7342-040; 7342-070; 7342-510 Illustration 208 Illustration 207 g00666542 1. Remove the filter element that is positioned in the operator’s compartment. g00760982 Coolant samples should be obtained from the coolant sample port. You should not obtain the samples from the drain valve or from the filler tube. 2. The filter element can be cleaned by using pressure air. Use a maximum air pressure of 205 kPa (30 psi). Direct the air from the clean side to the dirty side. For additional information about sampling the coolant, see Operation and Maintenance Manual, SEBU6250, “Caterpillar Machine Fluids Recommendations” or consult your Caterpillar dealer. 3. Look through the filter toward a bright light. Inspect the element for damage. Inspect the gaskets for damage. Replace damaged filters. Perform a Coolant Analysis (Level 1) at 250 hours for systems that contain diesel engine antifreeze/coolant (DEAC). 4. Install the filter element. Level 1 results may indicate a need for Level 2 Analysis. Note: Clean the filters more often in dusty conditions. i01521751 Coolant Sample - Obtain SMCS Code: 1395-554 Illustration 209 g00760982