Download Instruction Manual

Transcript
REAR PANEL
DANGER
Potentially lethal voltages may exist within this unit, even with the power shut off. Only
qualified personnel should attempt to service this unit. Failure to observe all safety precautions may result in personal injury.
POWER INPUT and FUSE HOLDER:
The LMC-20 can be configured to use either 120 V ac or 240 V ac. The voltage
selected is controlled by the CORCOM power card which is installed in the slot below the
fuse holder. To remove the card use a pair of needle nosed pliers and pull out. To configure
for 120 volts turn card so the 120 is right side up and facing you. For 240 volts turn card over
and turn so 240 is right side up and facing you. Insert card into slot. Make sure the fuse is
the right one for the voltage selected. 120 volts requires the 2 amp SB fuse and 240 volts
requires the 1 amp SB fuse.
11