Download Chapter 2 Installing the Micro-Tech 3100
Transcript
Micro-Tech 3100 Appendix Figure B-8: Current Output Board Wiring Diagram (Type A) Type B: Analog Input/Output board has two ±5 VDC differential inputs (Appendix Figure B-9) and two user definable 0-20/4-20 or 20-4/20-0 mA outputs (Appendix Figure B-6). Inputs None Moisture Compensation Outputs None Net Weight Gross Weight Tare Peak Analog inputs are +/-5 VDC. Jumpers W3 and/or W4 are used to select 240 ohm impedance for 0-20/4-20 mA inputs (see Appendix Figure B-10). Type: Differential voltage input (0-20 mA or 4-20 mA with internal resistor, jumper selectable) Range: 0-5 volt, or ±5 volt, programmable Input impedance: 100 k nominal (differential) Maximum usable input voltage: 106% of full scale Non-isolated Max. non-destructive input voltage: 12 V peak Field wiring: Connections are made to the terminal strip on bottom edge of the analog board. Note that connector is removable for ease of termination. REC XXXX B-11 Formattato: XRef_Link