Download 3D - Rapid Electronics
Transcript
Command Descriptions RS232? (Query Only) Returns the RS232 settings. Group RS-232 Syntax RS232? Returns Examples The current RS-232 settings. RS232? might return the following string: RS232:BAUD 9600; SOFTFLAGGING 0; HARDFLAGGING 1; PARITY NONE; TRANSMIT:TERMINATOR LF RS232:BAUd Sets or queries the RS-232C interface transmission speed. If no flow control (flagging) is used, commands may be received faster than the oscilloscope can process them. Also, if another command is sent immediately after this command, without waiting for the baud rate to be programmed, the first couple of characters may be lost. Conditions This command applies to the TDS200, TDS1000, TDS2000, and TPS2000 Series only. Group RS-232 Syntax RS232:BAUd <NR1> RS232:BAUd? Arguments Examples <NR1> which can be 300, 600, 1200, 2400, 4800, 9600, or 19200. RS232:BAUD 9600 sets the transmission rate to 9600 baud. RS232:HARDFlagging Sets or queries the state of RS232 hard flagging. When hard flagging is enabled, the oscilloscope sends data if CTS (Clear To Send) is asserted. When receiving data, the oscilloscope asserts RTS (Request To Send) until the input buffer is almost full. When the oscilloscope no longer asserts RTS, it continues to read 2-140 TDS200, TDS1000/2000, TDS1000B/2000B, TDS2000C, TPS2000 Programmer