Download EUROCONTROL
Transcript
Procedure a P 61 Verification Receiving Frequency Acceptance. b Performance specifications MS 3.2.2 - MT 5.4.1.2 . c Fixed settings Interrogator at nominal setting except the frequency; PRF 450 Hz XPDR code : A 1642 . d Test progress 100 [ interrogation reply ] sequences for levels at input XPDR from –60 dBm >> −80 dBm repeated for 1029 >> 1031 MHz in 0.1 MHz steps. e Measurement & display The program extracts each input power level where the reply % crosses the value 90%; Diagram : MTL vs. input frequency. Procedure a P 62 Verification Sidelobe Suppression vs. P1 / P2 Level Ratio. ... idem Ramp Test set (see page 18) but with levels at XPDR input running from -21 to MTL + 3dB. Procedure a P 63 + 82 Verification Sidelobe Suppression vs. P1 >> P2 Spacing. b Performance specifications MS 3.8 - MT 5.4.4 . c Fixed settings Interrogator at nominal setting; PRF 450 Hz; P2 at nominal width; XPDR code : A 1642, altimeter at zero; d Test progress P2/ P1 ratio varying from -12 >> + 3 dB, per 1 dB steps 100 [ interrogation reply ] sequences for each step repeated for 3 levels at XPDR input : -21, -50 dBm & MTL + 3 dB. Mode A, C & Intermode A, C. e Measurement & display For each of the 4 Modes and the 3 input power levels : a diagram : reply % vs. P1 >> P2 spacing, tolerance areas shown. Transponders Test Benches Requirements 43