Download Tune It 2

Transcript
Digital output 1&2
There is one digital output in the master and one in the slave which can be turned on
and off depending rpm and an optional analog input. The output is grounded when
it’s turned on. This means that you connect +12V separately from the battery or
ignition key to whatever you would like to control (relay, light etc).
RPM On
At what rpm the output should be turned on.
RPM Off
At what rpm the output should be turned off again.
Analog On At what analog signal the output should be turned on.
Analog Off At what analog signal the output should be turned of again.
The green area in the box next to each control shows when the output is turned on.
Page - Analog Out
For a better understanding of the tuning principles see the chapter on Signal limiting.
Page 53