H P M O U N T I N G & P I P I N G HYDRONIC SYSTEMS CONNECTIONS The Model HP-M2-Series may be used as either a Paloma Pak/Hytech boiler replacement or as a new wall-mount installation. Carefully unpack HP unit. Read all installation instructions before starting the installation. Remove the Front removable jacket and find the plumbing accessories package inside the unit. The HEATMAKER HP-M2 Series is supplied with the necessary fittings to match the Paloma Pak supply and return piping. If the original wall bracket is compatible with the slotted mounting holes on the rear of the HP-M2, the supply and return pipe unions attach directly to the existing piping. If the installation is new or if the old bracket is incompatible or unusable, the return and supply connections will require repiping to match the HP-M2 connections. WALL MOUNTING INSTRUCTIONS PALOMA/HYTECH REPLACEMENT Hang the HP-M2 as assembled from the manufacturer onto the existing wall bracket. Do not remove the brackets which are attached to the new unit. If the existing wall bracket does not align with the slotted mounting holes on the rear of the HPM2, remove the old bracket from the wall and follow instructions for new wall mount below. PLUMBING ACCESSORIES INSTALLATION NEW WALL MOUNT INSTALLATION Remove the bolts, nuts and washers that secure the two mounting brackets to the bottom and rear of the HP-M2 cabinet. Remove the U-channel spacer bracket from each wall bracket and discard. (Spacer brackets are used only with original bracket in Paloma Pak/Hytech retrofit installations) 1) Attach boiler drain plumbing accessory to the labeled return on the bottom of the HP-M2. 2) Separate Thermostatic Union Assembly halves and thread the 1" nipple side to the labeled supply on the bottom of the HP-M2. Attach the remainder of the union assembly onto the top half of the union. Be sure to use appropriate thread sealers to assure leak-tight joints. 3)a. Where the HP-M2 is a direct replacement for a Paloma Pak/Hytech the installation is completed by connecting union halves together. b. If the installation is new, refer to the piping schematics and instructions on page 10 -12. Attach the included mounting template to the selected wall location. Mark and drill holes for appropriate mounting hardware at the template specified locations. Remove template from the wall and securely affix the two wall brackets to the wall surface with appropriate mounting hardware (provided by installer). GAS SUPPLY CONNECTION If the installation is a direct retrofit, the gas supply will require re-piping to connect to the HP-M2 gas inlet. If the gas is supplied from below the unit, be sure to run supply pipe to a point higher than the vent center line before connection to the unit gas valve. Lift the HP-M2 onto the wall brackets and re-assemble the bolts, nuts and washers to affix the unit onto the wall brackets. NOTE: DO NOT REINSTALL THE U-CHANNEL SPACER BRACKETS WHEN MOUNTING THE WALL BRACKETS DIRECTLY TO A WALL. On new installations refer to the gas piping section for gas pipe sizing and related information. 14