Download WINDSOR 700 SERVICE MANUAL
Transcript
GUARDALL LTD Systems Development Group PO Box 233, Chubb House Staines Road West Sunbury-on-Thames Middlesex TW16 7XY UNITED KINGDOM WINDSOR 700 SERVICE MANUAL Version 8.4 Manual No. 320534 CONTENTS USING THIS MANUAL.......................................................................................................................................4 USING THE KEYPAD.........................................................................................................................................5 ABBREVIATIONS ...............................................................................................................................................7 MENU TREE : ENGINEERING.........................................................................................................................8 MENU TREE : CONFIGURATION...................................................................................................................9 FUNCTIONS: CLOCK : SET..........................................................................................................10 CONFIGURE : CONCENTRATOR........................................................................11 CONFIGURE : COPY CONFIGURATION............................................................14 CONFIGURE : DORMITORY................................................................................16 CONFIGURE : EMERGENCY CONFIGURE .......................................................19 CONFIGURE : ENTRY/EXIT ROUTE ..................................................................20 CONFIGURE : HOLIDAY......................................................................................24 CONFIGURE : LOBBY ACCESS ..........................................................................26 CONFIGURE : OUTPUT DRIVERS ......................................................................30 CONFIGURE : POINT INPUT ...............................................................................32 CONFIGURE : POINT OUTPUT ...........................................................................39 CONFIGURE : REMOTE COMMS (COMMUNICATIONS TYPE) ....................45 CONFIGURE : REMOTE COMMS (EVENT GROUPS) ......................................48 CONFIGURE : REMOTE COMMS (SERIAL EQUIPMENT) ..............................53 CONFIGURE : RESPONSES..................................................................................56 CONFIGURE : SCHEDULE ...................................................................................57 CONFIGURE : START/END CONFIGURATION ................................................60 CONFIGURE : UI ...................................................................................................62 CONFIGURE : ZONE .............................................................................................67 DEFINE : ACPO MODE .........................................................................................74 DEFINE : ATM TIMES ..........................................................................................75 DEFINE : AUTO. BATTERY TEST ......................................................................76 DEFINE : AUTO. BELL MUTE .............................................................................78 DEFINE : AUTO. DETECTOR TEST....................................................................79 DEFINE : AUTO. LOG-OFF...................................................................................81 DEFINE : AUTOMATIC SHUNT ..........................................................................82 DEFINE : AUXILIARY POINT LOGGING...........................................................83 DEFINE : BANK/COMMERCIAL .........................................................................84 DEFINE : BATTERY TEST ON SET ....................................................................85 DEFINE : BELL TEST TIMEOUT.........................................................................86 DEFINE : DURESS ALARM..................................................................................87 DEFINE : GROUP SHUNT ....................................................................................88 DEFINE : HS SHUNT .............................................................................................91 DEFINE : INOVA MPC CARD IDS .......................................................................94 2 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F FUNCTIONS (contd.): DEFINE : INVALID PIN RESPONSE ...................................................................95 DEFINE : IP PORTS ...............................................................................................96 DEFINE : LIMIT TIME ADJUST...........................................................................97 DEFINE : LINE FAULT OVERRIDE ....................................................................98 DEFINE : LOG-IN METHOD.................................................................................99 DEFINE : MANAGED RESET .............................................................................100 DEFINE : NEW PIN LOCKOUT..........................................................................101 DEFINE : PIN COMMAND FACILITY...............................................................102 DEFINE : PIN EXPIRY ........................................................................................103 DEFINE : PREVENT AUTO SET ALARMS.......................................................104 DEFINE : RESET AUTHORITY..........................................................................105 DEFINE : SCHEDULE ALARM ..........................................................................106 DEFINE : TAMPER RESET .................................................................................107 DEFINE : UI LOCKOUT ......................................................................................108 DEFINE : VERIFY ALARM.................................................................................109 DEFINE : WORK LATE TYPE ............................................................................111 POINT INPUT : ISOLATE/DEISOLATE ............................................................112 RESET : NET RESTART......................................................................................114 RESET : SERVICE................................................................................................115 SERVICEMAN : COMMISSION REMOTE COMMS ........................................116 SERVICEMAN : LOG-ON ...................................................................................119 SERVICEMAN : PANEL ACCESS ......................................................................120 SERVICEMAN : REMOTE COMMS (ENCRYPTION)......................................121 SERVICEMAN : REMOTE CONFIGURATION.................................................122 SET : FORCE ........................................................................................................123 SET : LINE FAULT OVERRIDE .........................................................................124 STATUS : DIAGNOSTIC LOG ............................................................................125 STATUS : ISOLATE LIST ...................................................................................126 STATUS : POINT INPUT (CALIBRATE) ...........................................................127 STATUS : PRINT CONFIGURATION ................................................................128 TEST : MONITOR ................................................................................................131 TEST : SOAK ........................................................................................................133 TEST : UI ..............................................................................................................135 Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 3 USING THIS MANUAL TO LOCATE A SECTION This manual is self-indexing. Each function is described in a section with a large-type title in the top corner in alphabetical order. A list of the functions is at the end of this section. THE FORMAT Each section has an introduction describing important features. Note, however, that this is not an exhaustive description due to space limitations. A flow-chart is given illustrating what appears on the keypad display and suggesting your response. If the display does not relate to this flow-chart it will probably be because of the system status or an invalid action. The displays that relate to this situation are at the end of each section under the title of ‘NOTES’. PROGRAMMABLE NAMES/NUMBERS The numbers and names of features such as zones, users, etc. are programmable and will depend on the installation. They are represented in this manual by the use of code letters. Capital letters represent numbers (i.e. a user number is UU representing a 2 digit number). Small letters represent names and indicate the maximum number of characters (i.e. a user name is uuuuuuuuuuuu). A list of these abbreviations is at the end of this section. MENUS Menus consist of a title followed by a numbered list. The composition of a menu will vary depending on the system configuration, system status and the user. The numbers of the items in a menu will vary. Hence in this manual the option numbers are not shown - only the menu title and the text of the option to select is illustrated. For example: ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Set Options │ │.. │ └────────────────┘ <-- Select 'Set Options' VARIABLE TEXT A text message on the keypad display may often have a number of alternatives. Where this is the case a line title is put in square brackets on the display symbol and the lines that will actually appear where appropriate are itemised below. For example: There are 3 possible text messages in line 3 of the display below: ┌────────────────┐ │POINT STATUS │ │.. │ │[point status ]│ │.. │ └────────────────┘ [point status ] normal off-normal tamper 4 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F USING THE KEYPAD DISPLAY The keypad has a 4-line 16 character LCD display. When the keypad is not being used the display will present the appropriate prompt for the user to log-on (see USER : LOG-ON in the User Manual) or when the keypad is inside a set zone the display may be blank. The keys will then be unusable and if anyone tried to use the keys it would cause an alarm. KEYS The keypad has 15 keys that are marked with symbols: 0-9 ▲▼ ✓ X C Numeric keys Keys used to scroll menus and lists 'Yes' and 'Enter' key 'No' key 'Clear' key INDICATOR LIGHTS The keypad has 8 lights to alert you to the following when they are lit. Note that, with the exception of the ‘Power' light, the lights will be held off until you log-on. POWER Mains supply is healthy BATTERY LOW The battery back-up capacity is low SHUNT ON A detector has been shunted (manually or automatically) INVESTIGATE The system is in a condition where a full set is not possible CALL ENGINEER A serviceman is required to reset or rectify the system LINE FAULT The communication to and from the Central Monitoring Station is faulty TAMPER A detector, keypad or other component has been in tamper ALARM A detector or other component has been in alarm TONES The keypad contains a sounder to emit tones. There are various tones which may emanate: a) A ‘beep' when a key is pressed b) A continuous tone for entry/exit procedure c) An intermittent tone for prewarning d) A sequence of tones for schedule expiry TO SELECT FROM A MENU The options in a menu take the form of a numbered list. To select an option it must be placed at the top line of the menu. Use the cursor keys (‘▲' and ‘▼') to scroll the menu. The ability to scroll is shown by a blinking symbol ♦ to the right of the menu title. To emphasise which is the top line of the menu the number associated with the option is made to blink. When the required option in the top line the selection is completed by pressing the ‘✓ ' key . Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 5 For example: To select the 'Set Options' menu from the ‘Function Select' menu ┌────────────────┐ │FUNCTION SELECT♦│ │1 Reset or Mute │ │2 Unset Options │ │3 Set Options │ └────────────────┘ Press '▼' twice and the display will scroll to show: ┌────────────────┐ │FUNCTION SELECT♦│ │3 Set Options │ │4 Test │ │5 View Status │ └────────────────┘ The ‘Set Options' line is now the top line of the menu. Press '✓ ' and the 'Set Options' menu will be selected. An alternative to the use of the '▲' and '▼' keys is to press the number of the required menu item. This will put the item into the menu top line. Note that the items shown in a menu are dependant on the status of the system and user. This means that the number of items in a menu is variable and the numbering of the items is variable. If in this process a mistake is made then pressing the 'Clear' key ('C') will usually return you to the preceding menu. TO SELECT CHARACTERS Text entry is required for descriptors (names). These may include letters or numbers. As the keypad has no letter keys available a special technique is used to enter descriptors. For a new descriptor the display will show the following symbol: ┌────────────────┐ │ │ │ │ │♦ │ │ │ └────────────────┘ The flashing cursor ♦ shows the first character position. Press '✓ ' and a space will be selected as the first character and the cursor moves to the right. If a character other than a space is required then use the '▲' or '▼' keys to step through the character set until the one required appears. The character set is as follows: ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz_+-=0123456789. Press '✓ ' to select the character and the cursor moves to the right for the next selection. If a mistake is made in the selection then press 'C' to move the cursor back. The process is completed when 16 characters have been entered, or alternatively when all the required characters have been entered then pressing '0' on the keypad will store the descriptor and complete the descriptor entry. In modifying an existing descriptor the process is similar. Each character will blink in turn to show that character may be changed. . 6 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F ABBREVIATIONS CC cccccccccccccccc Concentrator address Concentrator descriptor E eeeeeeeeeeeeeeee Entry/Exit route number Entry/Exit route descriptor G gggggggggggggggg Shunt group number Shunt Group descriptor H hhhhhhhhhhhhhhhh High Security Shunt group number High Security Shunt group descriptor III iiiiiiiiiiiiiiii Point Input number Point Input descriptor K kkkkkkkkkkkkkkkk Keypad number Keypad descriptor OOO oooooooooooooooo Point Output number Point Output descriptor R rrrrrrrrrrrrrrrr Remote Site number Remote Site descriptor SS ssssssssssssssss Schedule number Schedule descriptor T Timed function number UU uuuuuuuuuuuuuuuu User number User descriptor (usually the name) ZZ zzzzzzzzzzzzzzzz Zone number Zone descriptor DD-mmm-YY DD-MM Date (day-in numerals, month-in letters, year-in numerals) Date (day-month in numerals) HH:MM HH:MM:SS Time (hours:minutes in numerals) Time (hours:minutes:seconds in numerals) N X Number displayed Number to be entered Conc HS PreW UI Concentrator High-Security Pre-Warning User Interface (Keypad) Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 7 MENU TREE : ENGINEERING 1. Reset or Mute 1. Reset or Mute 2. Unset Options 2. Net Restart 1. Single Zone 3. Set Options 3. Clear Alarms 2. Multiple Zone 4. Test 4. Quit 3. By Schedule 5. View status 4. Quit 6. Point Control 1. Full Unset 7. PIN/User menu 2. Partial Unset 8. Time functions 3. Late Working 1. Single Zone 9. Configuration 4. Early Opening 2. Multiple Zone 0. Quit 5. Substitute Day 3. By Schedule 6. Quit 4. Quit 1. Full Set 1. All Zones 2. Partial Set 2. Single Zone 3. Test Set 3. Multiple Zone 4. Temporary Set 4. By Schedule 5. Extended Set 5. Quit 6. Line Fault O/R 7. Quit 1. System 2. By Schedule 1. Walk test 3. Quit 2. Bell test 3. Detector test Nos of days for closure 4. Soak test 5. Power tests 1. Battery Test 6. Other tests 2. Supply Test 7. Quit Point Monitor Test 1. System Status 2. Point Status 1. Cont Print On 3. Zone Status 2. Print Historic Log 4. Historic Log 3. Stop Printout 5. Schedules 4. View Historic Log 6. Tests Active 5. Print Acc Log 7. Serial Nos 6. View Acc Log 8. Quit 7. Print Config 8. Quit 1. Shunt Point 2. Isolate Point 3. Point O/P Control 4. Group Shunt 5. Quit 1. View users 2. Change master 3. Panel access 4. Commission RC 5. Decommission 6. Comms encrypt 7. Remote config 8. Quit 1. Set clock 2. Time adjust 3. Hour adjust 4. Holidays First day 5. Quit Last day Zones See Configuration Tree 8 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F MENU TREE : CONFIGURATION 1. System 1. Def Time Param 1. UI lockout time Max. no. of failed PINs 2. Zone 2. O/P drives 2. Auto logoff UI lockout time 3. Dormitory 3. Responses 3. New PIN lockout 4. UI Port 4. Concentrator 4. PIN expiry time 5. Point I/P 5. Remote Comms 5. Schedule Alarm PIN lockout time 6. Point O/P 6. Bell test t/o PIN change time 7. Misc Sys Params 7. Timed functions 1. Not used 8. E/E Route 8. ATM times Schedule timer ? 2. Detector Test 6. Schedule A C R V 7. Emerg Reconfig 8. Copy Config 9. End Config Auto Logoff time 9. Lobby Access 3. Battery Test Bell test timeout 4. Comms Test Prewarn connected O/C 1 Type Zone number A - Add M - Modify R - Remove V - View C - Change D - Delete A R M V Descriptor A C D V A C M V Type O/C 2 Type PIN entry wait period C/C Type Access period Sounder Duration No. of Isolated points Strobe Delay No. of Shunted points Strobe Duration Auto Set ? Latent Period Restricted Unset ? Hide Zone on menu ? A C R V 3. PAD 4. V.25bis 5. Hayes Prewarning Duration Mains Fail Delay A M V ATM controller ? A D M V Secure zone ? Physical Address Linked zones Type Command Restricted ? Extra O/P ? 2. Serial Equip 3. Comms Type Nos of Pts in D1 4. Event Groups D1 points 5. INOVA MPC Nos of Pts in D2 6. IP Ports A M R V D2 points First Delay t1 Second Delay t2 UI Address Descriptor Type Zone Access Enabled in set zone ? Enabld in unset zone? Set/Unset menu ? Lobby access ? 7. Windsor Modem Baud Rate 8. WModem HDX Monitor Line? 9. INOVA Session Timeout 0. Direct Router Address 1. Not used Subnet Mask 2. General O/P 1. Parallel 4. Interdial 2 2. Ademco Emul 5. Ademco 3. Serial 6. Plug On 7. Telecom ABC Primary 8. Internet 2 Secondary MasterCard Event Group number Enter ID System messages Zone messages Point Output number Duress type Physical address Point messages Duress confirmation ? Descriptor Duress text Normal Point State 1. Type 1 Unset Zone Duress Point type 2. Type 2 Input Driven ? Zone State Gated ? Zones Fixed Increment ? 3. Type 3 Full User Reset ? 4. Type 4 5. Not used Bank/Commercial ? System State Gated ? R M V 1. High Security Keyswitch ? Card login ? 6. Hayes HDX Communicator: Port Address A M V 1. Remote Sites Dormitory number Port number 3. Internet 1 Dual PIN Access ? Rearm delay 2. ChubbCOM Sounder Delay E/E route Auto Unset ? 1. Not used Access period repeat 1. Duress Alarm 2. Group Shunt 2. Work Late Type R M V Descriptor Add Point Remove Point 3. Reset Authority 1. Aux Pt Logging 4. Bank / Commercial 2. Keypad Alarm Point Input number 5. Shunt List 3. BS4737 Mode Descriptor 6. Line Fault Override 4. PIN Commands Point type 7. Auto Bell Mute 5. ACPO TX Reset Shuntable ? 8. Login Method 6. Managed Reset Isolatable ? 9. More Parameters 7. Auto. Shunt 1. Verify Alarm 8. Limit Time Adjust 2. Test on set 9. More Parameters 3. Tamper reset Points on E/E On entry is point: Not used E/E Times On exit is point: Exemptable ? Displayable ? Verifiable ? Point attribute Detector Test ? Physical address Wiring type Zones E/E Route number Add Point Remove Point Descriptor Route Point Entry/Exit Point Timed set ? Verifiable ? Buffer Point Open time Close time Thresholds 1. Times Auto Shunt Delay 2. Card AMRV Alarm Delay Card number Prefix length digits UK double loop Select Schedule Descriptor UK single loop + Digits of card prefix + UI CDN double loop Follow Instructions High security Zones Mon - Sun 1. From Prom Pack 2. To Prom Pack 1. Mod Schedule Earliest Early Opening 2. Delete Schedule Earliest Norm.Opening Latest Normal Opening 3. Quit Latest Normal Closing Latest Late Working Config. Number Keep old user table? Descriptor Night Alarm 1 Night Alarm 2 Night Alarm 3 24 Hour PA PA (Day) PA (Silent) PA (Day,Silent) Battery Monitor Signalling Control Point 24 Hour Warning 24 Hour Alarm Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 9 CLOCK : SET This facility is used to set the date and time. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Time functions│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TIME FUNCTIONS ♦│ │.. │ │. Set clock │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SET CLOCK │ │Date │ │ dd-mm-yyyy │ │ │ └────────┬───────┘ ┌────────┴───────┐ │SET CLOCK │ │Time │ │ hh:mm │ │ │ └────────┬───────┘ ┌────────┴───────┐ │SET CLOCK │ │[day ]│ │DD-MMM-YY HH:MM │ │Press YES or NO │ └────────────────┘ [day ] Monday Tuesday Wednesday Thursday Friday Saturday Sunday 10 <-- Select 'Time functions' <-- Select 'Set clock' Specify Enter 2 Enter 2 Enter 4 date. digits (day). Press '✓ ' digits (month). Press '✓ ' digits (year). Press '✓ ' Specify time. Enter 2 digits (hour). Press '✓ ' Enter 2 digits (minute). Press '✓ ' Display of date and time for confirmation. Press '✓ ' to update the clock Press 'X' to abort Returns to 'TIMED FUNCTIONS' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : CONCENTRATOR This facility is used to configure the concentrators which are connected to the Data Gathering Network (DGN). 8 Way 4 Way Monarch Daughter board 8 point inputs used on Concentrator which therefore uses 2 address 'slots' 4 point inputs used on Concentrator which therefore uses 1 address 'slot' Guardall product - a wireless Concentrator Increases configurable outputs from 1 to 3 on a 4-way Concentrator and from 1 to 8 on an 8-way Concentrator For the configuration of the Concentrator wiring type (i.e. End-of-Line, etc) see CONFIGURE : POINT INPUT ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Configuration │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Concentrator │ │.. │ └────────────────┘ <-- Select 'Configuration' <-- Select 'System' <-- Select 'Concentrator' CONCENTRATOR (Add) ┌────────────────┐ ♦│ │CONCENTRATOR │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │CONCENTRATOR │ │Enter physical │ │address - xx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │CONCENTRATOR C │ │[line 2 ]│ │[conc type menu]│ │[conc type menu]│ └───────┬────────┘ [line 2 ] 8 way type 4 way type Monarch type <-- Select 'Add' Specify concentrator address. Enter 2 digit number. Press '✓ ' Specify type of concentrator. Use '▲' or '▼' to scroll required type to line 3. Press '✓ ' [conc type menu ] . 8 Way . 4 Way . Monarch CONFIGURE : CONCENTRATOR (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 11 CONFIGURE : CONCENTRATOR (Add) continued ┌───────┴────────┐ │CONCENTRATOR C │ │[daughter board]│ │Change?YES or NO│ │ │ └────────────────┘ [daughter board ] Extra O/P UNUSED Extra O/P USED If 8 Way or 4 Way: Specify whether a daughter board is fitted. Press '✓ ' to change displayed status Press 'X' to retain displayed status Returns to 'CONCENTRATOR' menu NOTES 'Add new ones' not in menu The system already has a full complement of concentrators. 'invalid number' The number selected is out-of-range. 'invalid address' The address selected is already configured. CONCENTRATOR (Modify) ┌────────────────┐ ♦│ │CONCENTRATOR │.. │ │. Modify │ <-- Select 'Modify' │.. │ └───────┬────────┘ │ .............continue as for CONCENTRATOR (Add) CONCENTRATOR (Remove) ┌────────────────┐ ♦│ │CONCENTRATOR │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE CONC │ │Enter physical │ │address - xx │ │ │ └────────────────┘ <-- Select 'Remove' Specify concentrator address. Enter 2 digit number. Press '✓ ' Returns to 'CONCENTRATOR' menu if successful CONFIGURE : CONCENTRATOR continued overleaf 12 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : CONCENTRATOR continued CONCENTRATOR (View) ┌────────────────┐ ♦│ │CONCENTRATOR │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │CONCENTRATOR │ │Enter physical │ │address - xx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW CONC CC │ │[type ]│ │[daughter board]│ │ │ └────────────────┘ [type ] Type - 8 Way Type - 4 Way Type - Monarch <-- Select 'View' Specify concentrator address. Enter 2 digit number. Press '✓ ' Display of concentrator type. Display of output capability. Press '✓ ' to continue [daughter board ] Standard O/Ps Extra O/P fitted Returns to 'CONCENTRATOR' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 13 CONFIGURE : COPY CONFIGURATION The PROM Pack allows configurations to be transferred between the Windsor 700 and the Windsor 700 Configuration Editor PC software or between Windsor 700s. Power should be removed before the PROM Pack is plugged into or removed from the Control Unit board. Note that if a configuration is transferred from one Windsor 700 to another and remote communications is in use, all remote sites should be decommissioned on the new Windsor 700 before using the remote communications facility (See SERVICEMAN : COMMISSION REMOTE COMMS.). . COPY CONFIG (From PROM PACK) ┌────────────────┐ ♦│ │CONFIG MENU │. .. │ │. Copy Config │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │COPY CONFIG ♦│ │. .. │ │. From prom pack│ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │INSTALLATION │ │Pack: x │ │Vigil: x │ │YES to continue │ └───────┬────────┘ ┌───────┴────────┐ │COPY CONFIG │ │Pack Vn - x:x │ │Vigil Vn - x:x │ │YES to continue │ └───────┬────────┘ ┌───────┴────────┐ │COPY CONFIG │ │Keep old user │ │table │ │Press YES or NO │ └────────────────┘ <-- Select 'Copy Config' <-- Select 'From prom pack' If the PROM Pack installation number is not the same as the Control Unit data: The installation data is displayed Press '✓ ' to continue Press 'X' to abort If the PROM Pack software version is not the same as the Control Unit: The software version numbers are displayed Press '✓ ' to continue Press 'X' to abort Specify whether the user data in the configuration on the Control Unit is to be retained or whether the user data in the PROM Pack is to be imposed. Press '✓ ' to retain the users Press 'X' to impose PROM Pack user data Returns to 'CONFIG MENU' NOTES ┌────────────────┐ │COPY CONFIG │ │From pack FAILED│ │checksum error │ │ │ └────────────────┘ The configuration data in the PROM Pack is corrupted and invalid. Transfer of this data is therefore prevented. CONFIGURE : COPY CONFIGURATION continued overleaf 14 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : COPY CONFIGURATION continued ┌────────────────┐ │CONFIG MENU ♦│ │. .. │ │. Copy Config │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │COPY CONFIG ♦│ │. .. │ │. To prom pack │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │INSTALLATION │ │Pack: x │ │Vigil: x │ │YES to continue │ └───────┬────────┘ ┌───────┴────────┐ │COPY CONFIG │ │Pack Vn - x:x │ │Vigil Vn - x:x │ │YES to continue │ └───────┬────────┘ ┌───────┴────────┐ │COPY CONFIG │ │Copying │ │please wait │ │ │ └────────────────┘ <-- Select 'Copy Config' <-- Select 'To prom pack' If the PROM Pack installation number is not the same as the Control Unit data: The installation data is displayed Press '✓ ' to continue Press 'X' to abort If the PROM Pack software version is not the same as the Control Unit: The software version numbers are displayed Press '✓ ' to continue Press 'X' to abort Wait for data to be transferred Returns to 'CONFIG MENU' NOTES ┌────────────────┐ │Copy has failed │ │Try new pack │ │Inform Technical│ │Support │ └────────────────┘ The configuration data transfer has failed due to the PROM Pack. Press 'C' to return to menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 15 CONFIGURE : DORMITORY This facility enables the configuration of the two dormitory areas. Dormitories are interrelated points intended to provide false alarm immunity from accidental activations. This works by allowing a limited amount of sensor activity in a set system without causing an alarm. This activity is allowed for, say, 8 seconds, and no alarm is given provided that the sensors return to normal within those 8 seconds and there is no further activity for, say, 20 minutes. To increase the security each dormitory is divided into 2 groups of detectors and once the 8 seconds (or another specified time) of tolerance has started in one of the groups, no activity is permitted in the other group without an alarm being generated. Set D1 Set D2 First delay Second delay The first group of points sharing the dormitory function The second group of points sharing the dormitory function The period, starting with the activation of a point in the dormitory, during which that point may remain off-normal without causing an alarm. Other points in the same set may also go off-normal but points in the other set must remain normal to avoid causing an alarm. The period, starting after the first delay, during which all points in the dormitory must remain normal to avoid causing an alarm. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. Dormitory │ │.. │ └────────────────┘ <-- Select 'Dormitory' DORMITORY (Add) ┌────────────────┐ ♦│ │DORMITORY │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DORMITORY │ │Enter dormitory │ │number:- x │ │ │ └───────┬────────┘ ┌───────┴────────┐ │DORMITORY D │ │Number of points│ │in set D1:- xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │DORMITORY D │ │Enter point for │ │set D1:- xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │DORMITORY D │ │Number of points│ │in set D2:- xxx │ │ │ └───────┬────────┘ <-- Select 'Add' Specify set number. Enter 1 digit number. Press '✓ ' Specify number of point inputs in set. Enter 3 digit number. Press '✓ ' Specify point input number. Enter 3 digit number. Press '✓ ' Repeat for number of points. Specify number of point inputs in set. Enter 3 digit number. Press '✓ ' CONFIGURE : DORMITORY (Add) continued overleaf 16 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : DORMITORY (Add) continued ┌───────┴────────┐ │DORMITORY D │ │Enter point for │ │set D2:- xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │DORMITORY D │ │First Delay t1 │ │= xx seconds │ │ │ └───────┬────────┘ ┌───────┴────────┐ │DORMITORY D │ │Second Delay t2 │ │= xx minutes │ │ │ └────────────────┘ Specify point input number. Enter 3 digit number. Press '✓ ' Repeat for number of points. Specify first delay time (0 to 60secs). Enter 2 digit number (00 to 60). Press '✓ ' Specify second delay time (0 to 60mins). Enter 2 digit number (00 to 60). Press '✓ ' Returns to 'DORMITORY' menu NOTES 'invalid number' The number selected is out-of-range or the number is a value already selected. 'Used by D1-retry' The point is already in set D1 and may not be in D2. DORMITORY (Remove) ┌────────────────┐ ♦│ │DORMITORY │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DORMITORY │ │Enter dormitory │ │number:- xx │ │ │ └────────────────┘ <-- Select 'Remove' Specify set number. Enter 2 digit number. Press '✓ ' Returns to 'CONFIG MENU' if successful DORMITORY (View) ┌────────────────┐ ♦│ │DORMITORY │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DORMITORY │ │Enter dormitory │ │number:- xx │ │ │ └───────┬────────┘ <-- Select 'View' Specify set number. Enter 2 digit number. Press '✓ ' CONFIGURE : DORMITORY (View) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 17 CONFIGURE : DORMITORY (View) continued ┌───────┴────────┐ │VIEW DORM D │ │Delay t1-N secs │ │Delay t2-N mins │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW DORM D │ │Point III in │ │set D1 ♦│ │iiiiiiiiiiiiiiii│ └───────┬────────┘ ┌───────┴────────┐ │VIEW DORM D │ │Point III in │ │set D2 ♦│ │iiiiiiiiiiiiiiii│ └────────────────┘ 18 Display first delay and second delay. Press '✓ ' to continue Display points in Set 1. Use '▲' or '▼' to scroll through list Press '✓ ' to continue Display points in Set 2. Use '▲' or '▼' to scroll through list Press '✓ ' to continue Returns to 'DORMITORY' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : EMERGENCY CONFIGURE This facility is not available with Version 8.4 ┌────────────────┐ │CONFIG MENU ♦│ │. .. │ │. Emerg Reconfig│ │. .. │ └────────┬───────┘ ┌────────┴───────┐ │ OPTION │ │NOT AVAILABLE │ │Press CLEAR │ │ │ └────────────────┘ <-- Select 'Emerg Reconfig' Warning that the emergency configuration facility is not available. Press 'C' to continue Returns to 'CONFIG MENU' Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 19 CONFIGURE : ENTRY/EXIT ROUTE This facility is used to configure Entry/Exit routes. Where there are no external means of unsetting a system it is necessary to establish an Entry route to allow the user to traverse a defined route within the premises, without causing an alarm, in order to reach a keypad and unset the system. Similarly an Exit route may be necessary to allow the user to leave the premises after setting the system. The Entry and Exit routes may be the same, or different. Entry point Exit point Route point Buffer point Exit Delay Time Entry Delay Time Timed setting Verifiable ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MODIFY SYSTEM ♦│ │.. │ │. E/E Route │ │.. │ └────────────────┘ A point which when tripped will start the entry procedure. A point which completes the exit procedure. A point which may be activated legitimately during the entry/exit procedure. A point which generates a prewarning if activated during the entry/exit procedure, by the user mistakenly deviating from the entry/exit route. This prewarning is canceled by returning the point to normal and logging-on at a keypad. Specifies the time within which the exit procedure must be completed. Specifies the time within which the entry procedure must be completed. Specifies whether the system is to be set following expiry of the exit time. An exit point is not required in systems with timed setting. Specifies whether Entry Timeout is to be a verifiable alarm (see VERIFY ALARM) <-- Select 'System' <-- Select 'E/E Route' ENTRY/EXIT ROUTE (Add) ┌────────────────┐ ♦│ │E/E ROUTE │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD E/E ROUTE │ │Enter route │ │number:- x │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD EE RTE E │ │Enter Descriptor│ │♦ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD E/E ROUTE E │ │.. │ │. Add point │ │.. │ └───────┬────────┘ <-- Select 'Add' Specify E/E route number. Enter 1 digit number. Press '✓ ' Specify E/E route descriptor. Select characters (see USING THE KEYPAD) Specify point to be used for entry/exit route Select 'Add point' (Menu may also contain 'change' and 'remove') CONFIGURE : ENTRY/EXIT ROUTE (Add) continued overleaf 20 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : ENTRY/EXIT ROUTE (Add) continued ┌───────┴────────┐ │ADD E/E ROUTE E │ │Enter Point │ │Number:- xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD E/E ROUTE E │ │On Entry is PT ♦│ │[point menu ]│ │[point menu ]│ └────────────────┘ [point menu ] . Not used . Route pt . Entry point . Buffer pt ┌───────┴────────┐ │ADD E/E ROUTE E │ │On Exit is PT ♦│ │[point menu ]│ │[point menu ]│ └────────────────┘ [point menu ] . Not used . Route pt . Exit point . Buffer pt ┌───────┴────────┐ │ADD E/E ROUTE E♦│ │.. │ │. Route complete│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD E/E ROUTE E │ │Exit delay time │ │xxxx - seconds │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD E/E ROUTE E │ │Entry delay time│ │xxxx - seconds │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD E/E ROUTE E │ │[timed set fct ]│ │route expiry │ │Change?YES or NO│ └────────────────┘ [timed set fct ] Timed Set on NOT Timed Set on Specify point on E/E route. Enter 3 digit number. Press '✓ ' Specify point input type for entry Use '▲' or '▼' to scroll required type to line 3. Press '✓ ' Specify point input type for exit Use '▲' or '▼' to scroll required type to line 3. Press '✓ ' <-- Select 'Route complete' Specify exit time. Enter 4 digit number (0000 to 3000). Press '✓ ' Specify entry time. Enter 4 digit number (0000 to 3000). Press '✓ ' Specify if timed setting is required. Press '✓ ' to change displayed status Press 'X' to retain displayed status CONFIGURE : ENTRY/EXIT ROUTE (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 21 CONFIGURE : ENTRY/EXIT ROUTE (Add) continued ┌───────┴────────┐ │ADD E/E ROUTE E │ │Entry timeout │ │[verify status ]│ │Change?YES or NO│ └────────────────┘ [status ] verifiable NOT verifiable Specify if entry timeout in alarm verify is required. Press '✓ ' to change displayed status Press 'X' to retain displayed status Returns to 'E/E ROUTE' menu NOTES 'invalid number' The number selected is out-of-range. 'invalid point' The number selected is not configured or it is already assigned. ENTRY/EXIT ROUTE (Modify) ┌────────────────┐ ♦│ │E/E ROUTE │.. │ │. Modify │ │.. │ └───────┬────────┘ <-- Select 'Modify' ............continues as for ENTRY/EXIT ROUTE (Add) ENTRY/EXIT ROUTE (Remove) ┌────────────────┐ ♦│ │E/E ROUTE │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE E/E ROUTE│ │Enter route │ │number:- x │ │ │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE E/E ROUTE│ │Remove route E? │ │eeeeeeeeeeeeeeee│ │Press YES or NO │ └────────────────┘ <-- Select 'Remove' Specify E/E route number. Enter 1 digit number. Press '✓ ' Display of E/E Route descriptor for confirmation. Press '✓ ' to remove Press 'X' to abort Returns to 'E/E ROUTE' menu ENTRY/EXIT ROUTE (View) ┌────────────────┐ ♦│ │E/E ROUTE │.. │ │. View │ │.. │ └───────┬────────┘ <-- Select 'View' CONFIGURE : ENTRY/EXIT ROUTE (View) continued overleaf 22 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : ENTRY/EXIT ROUTE (View) continued ┌───────┴────────┐ │VIEW E/E ROUTE │ │Enter route │ │number:- x │ │ │ └───────┬────────┘ ┌───────┴────────┐ │E/E E - PT.III ♦│ │iiiiiiiiiiiiiiii│ │[point use ]│ │[point use ]│ └────────────────┘ [point use ] Entry pt Exit pt Entry route pt Exit route pt Entry Not used Exit Not used ┌───────┴────────┐ │VIEW E/E ROUTE E│ │Entry delay-xxxx│ │Exit delay-xxxx │ │seconds │ └───────┬────────┘ ┌───────┴────────┐ │VIEW E/E ROUTE E│ │[set fct ]│ │route expiry │ │[verify status ]│ └────────────────┘ [set fct ] Timed Set on NOT Timed Set on [verify status verifiable NOT verifiable Specify E/E route number. Enter 1 digit number. Press '✓ ' Display of point input(s) on route. Display of point function. Use '▲' or '▼' to scroll point details Press '✓ ' to continue Display of entry time period. Display of exit time period. Press '✓ ' to continue Display of set function on route expiry. Press '✓ ' to continue Returns to 'E/E ROUTE' menu ] Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 23 CONFIGURE : HOLIDAY This facility enables the programming of specified days as 'holidays' which override the schedule for those days. The 'holidays' act as a schedule closed window and, as such, inhibit the zone(s) associated with the schedule from being unset. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Time functions│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TIME FUNCTIONS ♦│ │.. │ │. Holidays │ │.. │ └────────────────┘ <-- Select 'Time functions' <-- Select 'Holidays' HOLIDAY (Add) ┌────────────────┐ ♦│ │HOLIDAYS │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SELECT FIRST DAY│ │of holiday │ │:DD-MM-YYYY │ │ │ └───────┬────────┘ ┌───────┴────────┐ │HOLIDAY STARTS │ │on [day ]│ │DD-mmm-YY │ │Press YES or NO │ └────────────────┘ [day ] Sunday Monday Tuesday Wednesday Thursday Friday Saturday ┌───────┴────────┐ │SELECT LAST DAY │ │of holiday │ │:DD-MM-YYYY │ │ │ └───────┬────────┘ ┌───────┴────────┐ │HOLIDAY ENDS │ │on [day ]│ │DD-mmm-YY │ │Press YES or NO │ └───────┬────────┘ <-- Select 'Add' Specify Enter 2 Enter 2 Enter 4 first digit digit digit day of number number number holiday. (day). Press '✓ ' (month). Press '✓ ' (year). Press '✓ ' Confirmation of first day of holiday. Press '✓ ' if correct Specify Enter 2 Enter 2 Enter 4 last day of holiday. digit number (day). Press '✓ ' digit number (month). Press '✓ ' digit number (year). Press '✓ ' Confirmation of last day of holiday. Press '✓ ' if correct CONFIGURE : HOLIDAY (Add) continued overleaf 24 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : HOLIDAY (Add) continued ┌───────┴────────┐ │HOLIDAY APPLIES │ │to zone ZZ │ │zzzzzzzzzzzzzzzz│ │Press YES or NO │ └────────────────┘ Specify zone(s) to which holiday is to apply. Press '✓ ' if displayed zone required Press 'X' if displayed zone not required Returns to FUNCTION SELECT menu if successful NOTES 'invalid date' The date entered is out-of-range or is already allocated as a holiday. HOLIDAY (Remove) ┌────────────────┐ ♦│ │HOLIDAYS │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE HOLIDAY │ │start DD-mmm-YY │ │end DD-mmm-YY │ │Press YES or NO │ └────────────────┘ <-- Select 'Remove' Confirm removal of holiday Press '✓ ' to remove holiday Press 'X' to view next holiday Press 'C' to quit without removing any holiday Returns to FUNCTION SELECT menu if successful HOLIDAY (View) ┌────────────────┐ ♦│ │HOLIDAYS │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW HOLIDAY ♦│ │starts DD-mmm-YY│ │ends DD-mmm-YY│ │ │ └───────┬────────┘ ┌───────┴────────┐ │HOLIDAY APPLIES │ │to zone ZZ ♦│ │zzzzzzzzzzzzzzzz│ │ │ └────────────────┘ <-- Select 'View' Specify holiday. Use '▲' or '▼' to scroll required holiday to lines 2 and 3. Press '✓ ' Display of zone list Use '▲' or '▼' to scroll zone list Press '✓ ' to continue Returns to menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 25 CONFIGURE : LOBBY ACCESS This facility is used to configure card access through a door. Typically this is for allowing access to the ATM lobby of a bank. The length of data read from a card is configurable. This allows a family of cards, which share a common data prefix, to operate the access. The data prefix length may be between 1 and 19 digits. (The maximum of 19 digits will normally mean individual cards may be identified if required). The prefix may contain "wildcard" digits which match any digit. Each card prefix is configured to be associated with specific readers. The card access is enabled for a configured period. The open period is applicable to all the readers in the system. It will be repeated for each day of the week and will be unaffected by holidays. Open time Close time The start of the period during which a valid card read will be acted upon. The end of the period during which a valid card read will be acted upon. When a card is swiped the following sequence of checks occurs. If any check fails the operation is aborted: The card prefix is checked. The card expiry date is checked. The lobby access period is checked for open period. If the above checks are passed then the associated point output is activated. This is usually used to activate a ‘door strike' which will allow the lobby door to open. To configure this point output see CONFIGURE : UI. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MODIFY SYSTEM ♦│ │.. │ │. Lobby access │ │.. │ └────────────────┘ <-- Select 'System' <-- Select 'Lobby access' TIMES ┌────────────────┐ ♦│ │LOBBY ACCESS │.. │ │. Times │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │LOBBY TIMES │ │Open time hh:mm │ │ │ │ │ └───────┬────────┘ <-- Select 'Times' Specify lobby open time start * Enter 2 digit number for hour. Press '✓ ' Enter 2 digit number for minute. Press '✓ ' CONFIGURE : LOBBY ACCESS continued overleaf 26 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : LOBBY ACCESS continued ┌───────┴────────┐ │LOBBY TIMES │ │Close time hh:mm│ │ │ │ │ └────────────────┘ * Specify lobby open time end * Enter 2 digit number for hour. Press '✓ ' Enter 2 digit number for minute. Press '✓ ' Returns to LOBBY ACCESS menu if successful If open time and close time are the same the lobby access will be untimed (ie 24 hours a day). If the close time is earlier than the open time the access will close the day after the open time. CARDS (Add) ┌────────────────┐ ♦│ │LOBBY ACCESS │.. │ │. Cards │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │LOBBY CARDS ♦│ │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD LOBBY CARD │ │Card number:- xx│ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD LOBBY CARD │ │Prefix length │ │xx digits │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD LOBBY CARD │ │Digits 1-NN │ │of card prefix │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD LOBBY CARD │ │Digits 17-NN │ │of card prefix │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD LOBBY CARD │ │Cannot be used │ │at UI N │ │Change?YES or NO│ └────────────────┘ <-- Select 'Cards' <-- Select 'Add' Specify card number (This may apply to a family of cards sharing the same data prefix). Enter 2 digit number (01 to 20). Press '✓ ' Specify length of card prefix (1 to 19 digits). Enter 2 digit number (01 to 19). Press '✓ ' Specify digits. Select digit numbers (0 to 9) for prefix. Use '▲' or '▼' for a wildcard, this is displayed as '.' If number of digits is 17 or more: Specify digits. Select digit numbers (0 to 9) for prefix. Use '▲' or '▼' for a wildcard, this is displayed as '.' Specify keypad(s) which are to recognize the card Press 'X' to retain displayed status Press '✓ ' to change displayed status Repeat for all UI numbers Returns to 'LOBBY CARDS' menu CONFIGURE : LOBBY ACCESS continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 27 CONFIGURE : LOBBY ACCESS continued CARDS (Modify) ┌────────────────┐ ♦│ │LOBBY ACCESS │.. │ │. Cards │ <-- Select 'Cards' │.. │ └───────┬────────┘ ┌───────┴────────┐ │LOBBY CARDS ♦│ │.. │ │. Modify │ <-- Select 'Modify' │.. │ └───────┬────────┘ │ .............continue as for CARDS (Add) CARDS (Remove) ┌────────────────┐ ♦│ │LOBBY ACCESS │.. │ │. Cards │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │LOBBY CARDS ♦│ │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE LOBBY CAR│ │Card number:- xx│ │ │ │ │ └────────────────┘ <-- Select 'Cards' <-- Select 'Remove' Specify card number. This may apply to a family Enter 2 digit number. Press '✓ ' Returns to 'LOBBY CARDS' menu CARDS (View) ┌────────────────┐ ♦│ │LOBBY ACCESS │.. │ │. Cards │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │LOBBY CARDS ♦│ │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW LOBBY CARD │ │Card number:- xx│ │ │ │ │ └───────┬────────┘ <-- Select 'Cards' <-- Select 'View' Specify lobby card number. Enter 2 digit number for card. Press '✓ ' CONFIGURE : LOBBY ACCESS continued overleaf 28 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : LOBBY ACCESS continued ┌───────┴────────┐ │VIEW LOBBY CARD │ │Digits 1-NN │ │of card prefix │ │NNNNNNNNNNNNNNNN│ └───────┬────────┘ ┌───────┴────────┐ │LOBBY CARD NN │ │Digits 17-NN │ │of card prefix │ │NNN │ └───────┬────────┘ ┌───────┴────────┐ │VIEW LOBBY CARD │ │[UI status ]│ │at UI N │ │ │ └────────────────┘ [UI status ] Can be used Cannot be used Digits in prefix. Press '✓ ' to continue If number of digits is 17 or more: Digits in prefix. Press '✓ ' to continue Keypad(s) which are to recognize the card Press '✓ ' to continue Returns to 'LOBBY CARDS' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 29 CONFIGURE : OUTPUT DRIVERS Configure sounders and strobes. The Mk1A hardware has the following configurable drivers: Prewarning driver Closed-circuit driver Open-circuit driver 1 Open-circuit driver 2 prewarning prewarning, sounder or strobe prewarning, sounder or strobe prewarning, sounder or strobe The Windsor 700 hardware has the following configurable drivers: Warn. 1 Warn. 2 ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MODIFY SYSTEM ♦│ │.. │ │. Mod O/P drives│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MOD O/P DRIVERS │ │Prewarn sounder │ │[connect state ]│ │Change?YES or NO│ └────────────────┘ [connect state ] connected not connected ┌───────┴────────┐ │OPEN CIRCUIT 1 ♦│ │[menu ]│ │[menu ]│ │[menu ]│ └────────────────┘ [menu ] . Not connected . Prewarning . Sounder . Strobe prewarning, sounder or strobe prewarning, sounder or strobe <-- Select 'System' <-- Select 'Mod O/P drives' Applies to Mk1A hardware only: Specify if pre-warning used. Press '✓ ' to change displayed status Press 'X' to retain displayed status This menu is present on the Windsor 700 but has no effect. Specify use for Open Circuit 1/Warn 1 Note: Top line of menu shows current status Use '▲' or '▼' to scroll required use to line 2. Press '✓ ' CONFIGURE : OUTPUT DRIVERS continued overleaf 30 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : OUTPUT DRIVERS continued ┌───────┴────────┐ │OPEN CIRCUIT 2 ♦│ │[menu ]│ │[menu ]│ │[menu ]│ └────────────────┘ [menu ] . Not connected . Prewarning . Sounder . Strobe ┌───────┴────────┐ │CLOSED CIRCUIT ♦│ │[menu ]│ │[menu ]│ │[menu ]│ └────────────────┘ [menu ] . Not connected . Prewarning . Sounder . Strobe Specify use for Open Circuit 2/Warn 2 Note: Top line of menu shows current status Use '▲' or '▼' to scroll required use to line 2. Press '✓ ' Applies to Mk1A hardware only: Specify use for Closed Circuit Note: Top line of menu shows current status Use '▲' or '▼' to scroll required use to line 2. Press '✓ ' This menu is present on the Windsor 700 but has no effect Returns to 'MODIFY SYSTEM' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 31 CONFIGURE : POINT INPUT Configure point input. Point type Shuntable Isolatable Exemptable The point response depends on the type (see Surveyors Guide). The point may be shunted (alarm response inhibited, tamper response monitored). The point may be isolated (alarm and tamper responses inhibited). The point may be exempted (if off-normal the zone containing it may still be set. Subsequently the point will become part of the alarm system from the time it goes normal Displayable The point may be displayed. Verifiable The point is in a verified alarm function (see CONFIGURE - VERIFY ALARM) Wiring type Depends on the Concentrator to which the point connects. Thresholds The boundaries for determining the pulse width signal on the DGN corresponding with the point condition (see Hardware Guide). Auto-shunt When a point goes into alarm the Auto Shunt timer for that point is started. When the timer expires then that point is shunted if it is still in alarm (subject to the shunt limit in the zone). This facility is used in conjunction with Auto Rearm. Note that Auto-shunt is not a recommended practice in some countries. Delayed Alarm Alarms can be delayed to enhance false alarm immunity. The operating mode of the delayed alarm depends on the configured value of delay period t2. If delay t2 is zero: The point must be constantly off-normal for the period t1 in order to cause an alarm. If delay t2 is non-zero The point going off-normal starts period t1. During period t1 alarms are not generated by this point remaining off-normal or by this point returning to normal and going off-normal again. At the end of period t1 the period t2 starts. If the point is still off-normal or goes off-normal during period t2 then an alarm is caused. At the end of t2 the sequence may re-start with t1 being triggered again. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. Point I/P │ │.. │ └────────────────┘ <-- Select 'Point I/P' POINT INPUT (Add) ┌────────────────┐ ♦│ │POINT I/P │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT I/P │ │Enter point │ │number - xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT I/P III │ │Enter descriptor│ │♦ │ │0=complete │ └───────┬────────┘ <-- Select 'Add' Specify point number. Enter 3 digit number. Press '✓ ' Specify point descriptor. Select characters (see USING THE KEYPAD) CONFIGURE : POINT INPUT (Add) continued overleaf 32 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : POINT INPUT (Add) continued ┌───────┴────────┐ │ADD PT I/P III │ │Select type │ │[point type ]│ │YES to accept │ └───────┬────────┘ [point type ] Night Alarm - 1 Night Alarm - 2 Night Alarm - 3 24 Hour PA PA (day) PA (silent) PA (day,silent) Battery Monitor Signalling Control point 24 Hour Warning 24 Hour Alarm Specify point type. Use '▲' or '▼' to scroll required point type to line 3. Press '✓ ' ┌───────┴────────┐ │ADD PT I/P III │ │Ctl Pt action │ │[function ]│ │YES to accept │ └───────┬────────┘ [function ] Clear Alarms Partial Set Partial Unset If Control Specify Use '▲' to line ┌───────┴────────┐ │ADD PT I/P III │ │[shunt state ]│ │Change?YES or NO│ │ │ └───────┬────────┘ [shunt state ] shuntable not shuntable If not a PA point: Specify if point is to be shuntable. Press '✓ ' to change displayed status Press 'X' to retain displayed status ┌───────┴────────┐ │ADD PT I/P III │ │[isolate state ]│ │Change?YES or NO│ │ │ └───────┬────────┘ [isolate state ] isolatable not isolatable ┌───────┴────────┐ │ADD PT I/P III │ │[exempt state ]│ │Change?YES or NO│ │ │ └───────┬────────┘ [exempt state ] exemptable not exemptable Point: function of Control Point. or '▼' to scroll required function 3. Press '✓ ' Specify if point is to be isolatable. Press '✓ ' to change displayed status Press 'X' to retain displayed status Specify if point is to be exemptable. Press '✓ ' to change displayed status Press 'X' to retain displayed status CONFIGURE : POINT INPUT (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 33 CONFIGURE : POINT INPUT (Add) continued ┌───────┴────────┐ │ADD PT I/P III │ │[display state ]│ │Change?YES or NO│ │ │ └───────┬────────┘ [display state ] displayable not displayable ┌───────┴────────┐ │ADD PT I/P III │ │[verify state ]│ │Change?YES or NO│ │ │ └───────┬────────┘ [verify state ] verifiable not verifiable ┌───────┴────────┐ │ADD PT III as ♦│ │[attribute menu]│ │[attribute menu]│ │[attribute menu]│ └───────┬────────┘ [attribute menu ] . normal point . buffer point . double buffer . safe shunt sla{ve} . safe shunt mas{ter} . Break Glass Pt ┌───────┴────────┐ │ADD PT III │ │Enter number of │ │control points x│ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT III │ │Enter control │ │point number xxx│ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT I/P III │ │[status ]│ │Detector test │ │Change?YES or NO│ └────────────────┘ [status ] in not in ┌───────┴────────┐ │ADD PT III │ │Det Test driving│ │point o/p :-xxx │ │ │ └───────┬────────┘ Specify if point is to be displayable. Press '✓ ' to change displayed status Press 'X' to retain displayed status For NA and 24HR points only: Specify if point is to be verifiable. Press '✓ ' to change displayed status Press 'X' to retain displayed status Specify attribute of point input. Use '▲' or '▼' to scroll required attribute to line 2. Press '✓ ' If double buffer or safe shunt slave: Specify number of control (linked) points. Enter 1 digit number. Press '✓ ' Specify control point number(s). Enter 3 digit number. Press '✓ ' Repeat for the all control points Specify if point is to be in detector test. (This implies the point input is testable via a point output i.e vibration detector) Press '✓ ' to change specified status Press 'X' to retain specified status If point in detector test: Specify point output providing stimulus. Enter 3 digit number. Press '✓ ' CONFIGURE : POINT INPUT (Add) continued overleaf 34 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : POINT INPUT (Add) continued ┌───────┴────────┐ │ADD PT I/P III │ │Physical address│ │ cc-pp │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT I/P III │ │Wiring type ♦│ │[wiring menu ]│ │[wiring menu ]│ └───────┬────────┘ [wiring menu ] . UK double loop . UK single loop . CDN dble loop . High Security ┌───────┴────────┐ │ADD PT I/P III │ │[zone stat] ZZ │ │zzzzzzzzzzzzzzzz│ │Change?YES or NO│ └───────┬────────┘ [zone stat] in zone NOT in zone ┌───────┴────────┐ │ADD PT I/P III │ │Thresholds │ │xx% yy% zz% │ │Change?YES or NO│ └───────┬────────┘ ┌───────┴────────┐ │ADD PT I/P III │ │Thresholds in % │ │ xxx,yyy,zzz │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT I/P III │ │Auto shunt delay│ │in seconds: xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT I/P III │ │Alarm Delay ♦│ │[delay menu ]│ │[delay menu ]│ └───────┬────────┘ [delay menu ] . None . When Set . When Unset . Always Specify address of point input. Enter 2 digit number (conc.). Press '✓ ' Enter 2 digit number (input). Press '✓ ' Specify concentrator type Use '▲' or '▼' to scroll required wiring type to line 3. Press '✓ ' Specify zone(s). Press '✓ ' to change displayed status Press 'X' to retain displayed status Repeat for all zones Specify thresholds for tamper and alarm. Press '✓ ' to change displayed thresholds Press 'X' to retain displayed thresholds If thresholds change selected: Specify thresholds: Enter 3 digit number. Press '✓ ' Enter 3 digit number. Press '✓ ' Enter 3 digit number. Press '✓ ' Specify automatic shunt delay. Enter 3 digit number (000 to 255). Press '✓ ' 000 = facility disabled Specify alarm delay type Use '▲' or '▼' to scroll required delay type to line 3. Press '✓ ' CONFIGURE : POINT INPUT continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 35 CONFIGURE : POINT INPUT continued ┌───────┴────────┐ │ADD PT I/P III │ │Delay t1 in ♦│ │[t1 units menu ]│ │[t1 units menu ]│ └───────┬────────┘ [t1 units menu ] . Seconds . Minutes ┌───────┴────────┐ │ADD PT I/P III │ │Delay t1: xxx │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT I/P III │ │Delay t2 in ♦│ │[t2 units menu ]│ │[t2 units menu ]│ └───────┬────────┘ [t2 units menu ] . Seconds . Minutes ┌───────┴────────┐ │ADD PT I/P III │ │Delay t2: xxx │ │ │ │ │ └────────────────┘ Specify delay t1 units Use '▲' or '▼' to scroll required delay units to line 3. Press '✓ ' Specify delay t1 (in secs or mins as above). Enter 3 digit number. Press '✓ ' Specify delay t2 units Use '▲' or '▼' to scroll required delay units to line 3. Press '✓ ' Specify delay t2 (in secs or mins as above). Enter 3 digit number. Press '✓ ' Returns to CONFIG PT I/P menu NOTES 'Add point' not in menu The max. number of points already configured. 'invalid number' Number is out-of-range, or the number has already been allocated. 'not avail retry' The number is allocated to a double buffer point or a safe shunt slave. POINT INPUT (Modify) ┌────────────────┐ ♦│ │POINT I/P │.. │ │. Modify │ <-- Select 'Modify' │.. │ └───────┬────────┘ │ .............continue as for POINT INPUT (Add) CONFIGURE : POINT INPUT continued overleaf 36 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : POINT INPUT continued POINT INPUT (Remove) ┌────────────────┐ ♦│ │POINT I/P │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE PT I/P │ │Enter point │ │number - xxx │ │ │ └────────────────┘ <-- Select 'Remove' Specify point input number. Enter 3 digit number. Press '✓ ' Returns to CONFIG MENU if successful POINT INPUT (View) ┌────────────────┐ ♦│ │POINT I/P │.. │ │. View │ <-│.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT I/P │ │Enter point │ │number - xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT I/P III │ │iiiiiiiiiiiiiiii│ │[point type ]│ │address cc-pp │ └───────┬────────┘ [point type ] see POINT INPUT (Add) ┌───────┴────────┐ │VIEW PT I/P III │ │Control point │ │[function ]│ │ │ └───────┬────────┘ [function ] see POINT INPUT (Add) ┌───────┴────────┐ │VIEW PT I/P III │ │[shunt state ]│ │[isolate state ]│ │[display state ]│ └───────┬────────┘ [shunt state ] is shuntable NOT shuntable Select 'View' Specify point input number. Enter 3 digit number. Press '✓ ' Display of Display of Display of Press '✓ ' point descriptor. point type. point address. to continue For Control Point: Display of Control Point function Press '✓ ' to continue Display of Display of Display of Press '✓ ' shuntable state. isolatable state. displayable state. to continue [isolate state is isolatable NOT isolatable ] [display state ] is displayable NOT displayable CONFIGURE : POINT INPUT (View) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 37 CONFIGURE : POINT INPUT (View) continued ┌───────┴────────┐ │VIEW PT I/P III │ │[exempt state ]│ │[verify state ]│ │[attribute ]│ └───────┬────────┘ [exempt state ] exemptable NOT exemptable ┌───────┴────────┐ │VIEW PT I/P III │ │Controlled by │ │III iiiiiiiiiiii│ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT I/P III │ │Wiring type │ │[wiring type ]│ │ │ └───────┬────────┘ [wiring type ] see POINT INPUT (Add) ┌───────┴────────┐ │VIEW PT I/P III │ │Threshold 1 nn% │ │Threshold 2 nn% │ │Threshold 3 nn% │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT I/P III │ │Auto shunt delay│ │in seconds: nnn │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT I/P III │ │Alarm delay │ │[delay type ]│ │ │ └───────┬────────┘ [delay type ] see POINT INPUT (Add) ┌───────┴────────┐ │VIEW PT I/P III │ │Delay t1: xxx │ │in [t1 units] │ │ │ └───────┬────────┘ [t1 units ] seconds minutes ┌───────┴────────┐ │VIEW PT I/P III │ │Delay t2: xxx │ │in [t2 units] │ │ │ └────────────────┘ [t2 units ] seconds minutes 38 Display of Display of Display of Press '✓ ' exemptable state. point attribute. verifiable condition. to continue [verify state verifiable NOT verifiable ] [attribute ] see POINT INPUT (Add) For double buffer and Safe Shunt Slave: Display of controlling point inputs Use '▲' or '▼' to scroll Press '✓ ' to continue Display of concentrator type. Press '✓ ' to continue Display of thresholds. Press '✓ ' to continue Display of Automatic Shunt delay. Press '✓ ' to continue Display of alarm delay type. Press '✓ ' to continue If alarm delay: Display of alarm delay period t1. Press '✓ ' to continue Display of alarm delay period t2. Press '✓ ' to continue Returns to 'CONFIG PT I/P' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : POINT OUTPUT Point Outputs are the output connections on a concentrator (and daughter board if fitted) by which external devices (i.e. indicators) are driven by the system. Point Outputs are assigned an address which incorporates the concentrator address and the address of the point on that concentrator. The first two Point Output addresses on a concentrator are used to provide Walk Test indications and therefore the first configurable point address is 03. Point Outputs may be programmed to react to the state of Point Inputs, zones, and/or the system. Monitor Latched Momentary Point Input Driven Zone state gated System state gated ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Point O/P │ │.. │ └────────────────┘ The point output follows the normal, off-normal state of the event The point output latches into an off-normal state following the trigger of the event The point output goes momentarily off-normal following the trigger of the event Up to 8 point inputs may control the point output. Multiple inputs are ORed to provide the point input control signal, and this is ANDed with the zone state and system state if these are selected. Up to 4 states of the zone may control the point output. Multiple zone conditions are ORed to provide the zone condition control signal, and this is ANDed with the point input control signal, if any. The system condition, if any, is ANDed with the zone and point input conditions <-- Select 'System' <-- Select 'Point O/P' POINT OUTPUT (Add) ┌────────────────┐ ♦│ │POINT O/P │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD POINT O/P │ │Enter point │ │number - xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT O/P OOO │ │Physical address│ │ cc-oo │ │ │ └───────┬────────┘ <-- Select 'Add' Specify point output number. Enter 3 digit number. Press '✓ ' Specify address of point output. Enter 2 digit number (conc.). Press '✓ ' Enter 2 digit number (point). Press '✓ ' CONFIGURE : POINT OUTPUT (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 39 CONFIGURE : POINT OUTPUT (Add) continued ┌───────┴────────┐ │ADD PT O/P OOO │ │Enter descriptor│ │♦ │ │0=complete │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT O/P OOO │ │The point state │ │is normally [st]│ │Change?YES or NO│ └───────┬────────┘ [st] ON OFF ┌───────┴────────┐ │ADD PT O/P OOO │ │[point menu ]│ │[point menu ]│ │[point menu ]│ └───────┬────────┘ [point menu ] . Momentary . Monitor . Latched ┌───────┴────────┐ │ADD PT O/P OOO │ │ Pulse delay │ │h:mm:ss->x:xx:xx│ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT O/P OOO │ │ Pulse duration │ │h:mm:ss-0:00:00 │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT O/P OOO │ │[link line 1 ]│ │[link line 2 ]│ │Change?YES or NO│ └───────┬────────┘ [link line 1 ] Point is Point IS NOT Specify descriptor. Select characters (see USING THE KEYPAD) Specify normal state of point output. Press '✓ ' to change specified state Press 'X' to retain state Specify type of point output. Use '▲' or '▼' to scroll required type to line 2. Press '✓ ' If momentary: Specify delay Enter 1 digit Enter 2 digit Enter 2 digit Specify Enter 1 Enter 2 Enter 2 before number number number active. (hours). Press '✓ ' (minutes). Press '✓ ' (seconds). Press '✓ ' active duration. digit number (hours). Press '✓ ' digit number (minutes). Press '✓ ' digit number (seconds). Press '✓ ' Specify if point output is controlled by point input status. Press '✓ ' to change the specified mode Press 'X' to retain the specified mode [link line 2 ] POINT I/P DRIVEN POINT I/P DRIVEN CONFIGURE : POINT OUTPUT (Add) continued overleaf 40 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : POINT OUTPUT (Add) continued ┌───────┴────────┐ │LINKED PT INPUTS│ │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT O/P OOO │ │Number of point │ │inputs - xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT O/P OOO │ │Enter next point│ │input - xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │LINKED PT INPUT♦│ │.. │ │. Complete │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD PT O/P OOO │ │[link line 1 ]│ │[link line 2 ]│ │Change?YES or NO│ └───────┬────────┘ [link line 1 ] zone state gated NOT zone state ┌───────┴────────┐ │ADD PT O/P OOO │ │[function link ]│ │[function state]│ │Change?YES or NO│ └───────┬────────┘ [function link ] ATM Bypass walk test detector test PA test Detr test fail set zone unset zone exiting zone entering zone zone compromise pre-warning sounder strobe zone in alarm zone in PA tamper in zone armed for entry schedule closing settable zone If point output is linked to point input: Specify linked point inputs. <-- Select 'Add' Specify number of point inputs. Enter 3 digit number. Press '✓ ' Specify point input number. Enter 3 digit number. Press '✓ ' Repeat for all linked points Specify if point input link is complete. If so: Select 'Complete' Specify if point output is controlled by zone(s) condition. Press '✓ ' to change the specified mode Press 'X' to retain the specified mode [link line 2 ] gated If zone state gated: Specify the zone states to control the point output function. Press '✓ ' to change the specified mode Press 'X' to retain the specified mode [function state] linked NOT linked CONFIGURE : POINT OUTPUT (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 41 CONFIGURE : POINT OUTPUT (Add) continued ┌───────┴────────┐ │ADD PT O/P OOO │ │[zone stat] ZZ │ │zzzzzzzzzzzzzzzz│ │Change?YES or NO│ └───────┬────────┘ [zone stat] in zone NOT in zone Specify zone(s) whose condition affects the point output Press '✓ ' to change the displayed status Press 'X' to retain the displayed status ┌───────┴────────┐ │ADD PT O/P OOO │ │[system link ]│ │gated │ │Change?YES or NO│ └───────┬────────┘ [system link ] system state not system state ┌───────┴────────┐ │ADD PT O/P OOO │ │[system state ]│ │[link ]│ │Change?YES or NO│ └────────────────┘ [system state ] line fault mains fail Detr test fail Specify whether system state affects the point output. Press '✓ ' to change the displayed status Press 'X' to change the displayed status If system state linked: Specify the system state(s) to control the point output function. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status [link linked NOT linked ] Returns to 'POINT O/P' menu POINT OUTPUT (Modify) ┌────────────────┐ ♦│ │POINT O/P │.. │ │. Modify │ <-│.. │ └───────┬────────┘ ┌───────┴────────┐ │MOD PT O/P │ │Enter point │ │number - xxx │ │ │ └───────┬────────┘ │ .............continue as Select 'Modify' Specify point output number. Enter 3 digit number. Press '✓ ' for POINT OUTPUT (Add) CONFIGURE : POINT OUTPUT continued overleaf 42 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : POINT OUTPUT continued POINT OUTPUT (Remove) ┌────────────────┐ ♦│ │POINT O/P │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE PT OP OOO│ │oooooooooooooooo│ │Press YES or NO │ │ │ └────────────────┘ <-- Select 'Remove' Specify point output(s) to be removed. Press '✓ ' to remove point Press 'X' to retain point POINT OUTPUT (View) ┌────────────────┐ ♦│ │POINT O/P │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT O/P │ │Enter point │ │number - xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT O/P OOO │ │oooooooooooooooo│ │Address cc-pp │ │[normal state ]│ └───────┬────────┘ [normal state ] Normally OFF Normally ON ┌───────┴────────┐ │VIEW PT O/P OOO │ │[type ]│ │ │ │ │ └───────┬────────┘ [type ] Monitor type Momentary type Latched type ┌───────┴────────┐ │VIEW PT O/P OOO │ │ Pulse delay │ │ h:mm:ss │ │ n:nn:nn │ └───────┬────────┘ <-- Select 'View' Specify point output number. Enter 3 digit number. Press '✓ ' Display of Display of Display of Press '✓ ' descriptor. address. normal state. to continue Display of point output type. Press '✓ ' to continue For momentary point: Display of delay before active. Press '✓ ' to continue CONFIGURE : POINT OUTPUT (View) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 43 CONFIGURE : POINT OUTPUT (View) continued ┌───────┴────────┐ │VIEW PT O/P OOO │ │ Pulse duration │ │ h:mm:ss │ │ n:nn:nn │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT O/P OOO │ │Point controlled│ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT O/P OOO │ │Linked to Point │ │Input III ♦│ │iiiiiiiiiiiiiiii│ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT O/P OOO │ │Zone state │ │controlled │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT O/P OOO │ │Linked to zone │ │state │ │[function link ]│ └────────────────┘ [function link ] see POINT OUTPUT (Add) ┌───────┴────────┐ │VIEW PT O/P OOO │ │Depends on state│ │of zone ZZ ♦│ │zzzzzzzzzzzzzzzz│ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT O/P OOO │ │System state │ │controlled │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT O/P OOO │ │Linked to system│ │state ♦│ │[system state ]│ └────────────────┘ [system state ] see POINT OUTPUT (Add) Display of time active. Press '✓ ' to continue If point input controlled: Display of point input controlled status. Press '✓ ' to continue Display of controlling points Use '▲' or '▼' to scroll points list Press '✓ ' to continue If zone state controlled: Display of zone state control status Press '✓ ' to continue Display of zone states linked. Use '▲' or '▼' to scroll zone states Press '✓ ' to continue Display of zones. Use '▲' or '▼' to scroll zone list Press '✓ ' to continue If system state controlled: Display of system state link status Press '✓ ' to continue Display of system states linked. Use '▲' or '▼' to scroll system states Press '✓ ' to continue Returns to ‘POINT O/P’ menu 44 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : REMOTE COMMS (COMMUNICATIONS TYPE) Alarms may be reported to the central station by three means: (i) a parallel communicator such as a Redcare STU or digidialer; (ii) a ChubbCOM emulating an Ademco dialler; (iii) a serial communicator such as ChubbCOM, a modem, or a PAD. Primary / Secondary The definition depends on the mode: Parallel Port Communicators : Applies to the Control Unit. Thus one communicator is designated the primary communicator and transmits the event messages unless a fault arises. Then the events are transmitted by the secondary communicator. Serial Port Communicators : Applies to the Remote Site. Thus one remote site is designated the primary site and one is designated the secondary site. (Note that this may simply refer to different hardware in the same place or be geographically separate.) ADEMCO Emulation ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Remote Comms │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOTE COMMS ♦│ │.. │ │. Comms. Type │ │.. │ └────────────────┘ The ChubbCOM communicator may be used as a dialler performing the same functions as an ADEMCO dialler. <-- Select 'System' <-- Select 'Remote Comms' <-- Select 'Comms. Type' COMMUNICATIONS TYPE (Add) ┌────────────────┐ ♦│ │COMMS. TYPE │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD │ │COMMS TYPE │ │[Comms type ]│ │[Comms type ]│ └───────┬────────┘ [Comms type ] Primary Secondary <-- Select 'Add' Select Primary or secondary. Use '▲' or '▼' to scroll required type to line 3. Press '✓ ' CONFIGURE : COMMUNICATIONS TYPE (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 45 CONFIGURE : COMMUNICATIONS TYPE (Add) continued ┌───────┴────────┐ │[comm type ]♦│ │[report type ]│ │[report type ]│ │[report type ]│ └────────────────┘ [comm type ] PRIMARY SECONDARY Specify type of reporting. Use '▲' or '▼' to scroll required type to line 2. Press '✓ ' [report type Parallel Ademco Emul. Serial ┌───────┴────────┐ │PARALLEL │ │Communicator: ♦│ │[Comm type ]│ │[Comm type ]│ └────────────────┘ [Comm type ] not used General o/p Internet I Interdial II ADEMCO Plug on Telecom CARE Internet II ] For Parallel: Specify type of communicator. Use '▲' or '▼' to scroll required communicator to line 3. Press '✓ ' NOTES No 'Add' in 'COMMS TYPE' menu ┌────────────────┐ │ADEMCO EMUL./ │ │SERIAL reporting│ │NOT available │ │Press CLEAR │ └────────────────┘ Primary & Secondary communications are already configured The ADEMCO EMULATION mode and SERIAL mode are not configurable at the keypad in the software version installed. COMMUNICATIONS TYPE (Modify) ┌────────────────┐ ♦│ │COMMS. TYPE │.. │ │. Modify │ <-- Select 'Modify' │.. │ └───────┬────────┘ │ .............continue as for COMMUNICATIONS TYPE (Add) CONFIGURE : COMMUNICATIONS TYPE continued overleaf 46 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : COMMUNICATIONS TYPE continued COMMUNICATIONS TYPE (Remove) ┌────────────────┐ ♦│ │COMMS. TYPE │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE │ │COMMS TYPE │ │1 Primary │ │2 Secondary │ └───────┬────────┘ ┌───────┴────────┐ │[comm type ]│ │Remove all │ │[type ] events│ │Press YES or NO │ └────────────────┘ [comm type ] PRIMARY SECONDARY <-- Select 'Remove' Select Primary or secondary. Use '▲' or '▼' to scroll required type to line 3. Press '✓ ' Request for confirmation to remove Press '✓ ' if removal required Press 'X' if removal not required [type ] Primary Secondary COMMUNICATIONS TYPE (View) ┌────────────────┐ ♦│ │COMMS. TYPE │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW │ │COMMS TYPE │ │1 Primary │ │2 Secondary │ └───────┬────────┘ ┌───────┴────────┐ │PRIMARY │ │PARALLEL EVENTS │ │communicator - │ │[comm type ]│ └───────┬────────┘ ┌───────┴────────┐ │SECONDARY │ │PARALLEL EVENTS │ │communicator - │ │[comm type ]│ └────────────────┘ <-- Select 'View' Select Primary or secondary. Use '▲' or '▼' to scroll required type to line 3. Press '✓ ' For Primary: Display of Communicator type. Use '▲' or '▼' to scroll. Press '✓ ' For Secondary: Display of Communicator type. Use '▲' or '▼' to scroll. Press '✓ ' Returns to menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 47 CONFIGURE : REMOTE COMMS (EVENT GROUPS) Configure remote comms. event groups. Events are the zone, point, system messages which are sent to a Remote Site. Events are collected together to form an 'Event Group'. The group is assigned a number which has a significance based on the type of communications: Parallel ADEMCO emulation Serial The Event Group number represents the parallel port pin which will be activated. The Event Group number represents the channel number. The Event Group number represents the channel number. Priority Events For ADEMCO emulation and Serial the priority of Event Reporting over Management functions must is selectable. If 'High Priority Events' are selected then any management function in progress when event information requires transmission is suspended and the events information will be sent. Note that if both the primary and secondary communicators are serial then the event group will go on either depending on the status of the receiver. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Remote Comms │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOTE COMMS ♦│ │.. │ │. Event Groups │ │.. │ └────────────────┘ <-- Select 'System' <-- Select 'Remote Comms' <-- Select 'Event Group' EVENT GROUPS (Add) ┌────────────────┐ ♦│ │EVENT GROUPS │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD GROUP ♦│ │1 Primary │ │2 Secondary │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD PRIMARY │ │Event Group │ │Enter No: xx │ │ │ └───────┬────────┘ <-- Select 'Add' Select primary or secondary. Use '▲' or '▼'to scroll required type to line 2. Press '✓ ' For Parallel/ADEMCO emulation: Select group number. Enter 2 digit number. Press '✓ ' CONFIGURE : EVENT GROUPS (Add) continued overleaf 48 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : EVENT GROUPS (Add) continued ┌───────┴────────┐ │ADD PRIMARY │ │Event Group │ │Enter No: xxxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │[group type ]│ │No. 1 [priority]│ │Priority Events │ │Change?YES or NO│ └────────────────┘ [group type ] PRIMARY SECONDARY ┌───────┴────────┐ │PRIMARY MESSAGE♦│ │[type menu ]│ │[type menu ]│ │[type menu ]│ └────────────────┘ [type menu ] . Group Complete . System message . Zone messages . Point messages . Door messages ┌────────────────┐ │SYSTEM MESSAGES │ │[system message]│ │[status ]│ │Change?YES or NO│ └────────────────┘ [system message ] ALL Alarm/Tamper Any Alarm Any Tamper Night Alarm only 24hr Point only PA Alarms only Battery Low Comms Fail Comms Test Tamper on Bell Tamper on Panel DG Network Fail UI Network Fail Mains Fail Autoset Demand System SET System UNSET Clock Changed Service log Max shunts Max isolates Processor Reset System Error For Serial Event Reporting: Select group number. Enter 4 digit number. Press '✓ ' For Serial Event Reporting/ADEMCO Emulation: Select priority. Press '✓ ' to change displayed status Press 'X' to retain displayed status [priority] Low High Select message type. Use '▲' or '▼' to scroll required type to line 2. Press '✓ ' If system messages required: Select system messages. Press '✓ ' to change displayed status Press 'X' to retain displayed status [status USED UNUSED ] CONFIGURE : EVENT GROUPS (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 49 CONFIGURE : EVENT GROUPS (Add) continued Late Work Active Work Early Activ{e} Any Zone SET Service access Any schd expiry Tamper set zone Duress PIN Incident Any INOVA InvAcc Any INOVA DurAcc Any INOVA HeldOp Any INOVA ForcOp Any INOVA LnFaul Any INOVA Tamper INOVA Comms Fail ISB failure Battery failure Pri. Comms Fail Sec. Comms Fail Test Message Verified Alarm Bat test failed ┌────────────────┐ │ZONE MESSAGES │ │[zone message ]│ │[status ]│ │Change?YES or NO│ └────────────────┘ [zone message ] Zone ZZ Alarm Zone ZZ Tamper Zone ZZ SET Zone ZZ UNSET Zone ZZ expiry Zone ZZ PA alarm Zone ZZ 24 hour Zone ZZ night Zone ZZ battery Zone ZZ max isol{ates} Zone ZZ max shun{ts} Zone ZZ em. unse{t} Zone ZZ Entry Du{ress} Zone ZZ has shun{t} Zone ZZ has isol{ate} ATM Zone ZZ byps{s} ZZ Autoset Fail Keypad U Locked If zone messages are required: Select zone messages. Press '✓ ' to change displayed status and move to next zone. Press 'X' to retain displayed status and move to next zone. Press '▲' and '▼' to move through the message types while leaving the zone unaltered. Entering a zone number and pressing '✓ ' goes to that zone number without changing the current displayed status. [status Zone ZZ USED Zone ZZ UNUSED ] UI U USED UI U UNUSED Zone ZZ Verify A{larm} CONFIGURE : EVENT GROUPS (Add) continued overleaf 50 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : EVENT GROUPS (Add) continued ┌────────────────┐ │POINT MESSAGES │ │Report point xxx│ │Point xxx [stat]│ │Change?YES or NO│ └────────────────┘ [stat ] USED UNUSED If Point messages are required: Select point messages. Press '✓ ' to change displayed status Press 'X' retain displayed status Entering a point number and pressing '✓ ' goes to that point without changing the current status. Press '▲' and '▼' to move 8 points at a time. ┌────────────────┐ │DOOR MESSAGES │ │[door function ]│ │Door x [status ]│ │Change?YES or NO│ └────────────────┘ [door function ] Door xx InvAcc Door xx DurAcc Door xx HeldOp Door xx ForcOp Door xx LnFaul Door xx Tamper If Door Messages are required: Select door function messages. Press '✓ ' to change displayed status Press 'X' to retain displayed status [status ] USED UNUSED EVENT GROUPS (Modify) ┌────────────────┐ ♦│ │EVENT GROUPS │.. │ │. Modify │ │.. │ └───────┬────────┘ <-- Select 'Modify' .............continue as for EVENT GROUPS (Add) EVENT GROUPS (Remove) ┌────────────────┐ ♦│ │EVENT GROUPS │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD GROUP ♦│ │1 Primary │ │2 Secondary │ │ │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE [type ]│ │Event Group │ │Enter No: xx │ │ │ └───────┬────────┘ <-- Select 'Remove' Select primary or secondary. Use '▲' or '▼'to scroll required type to line 2. Press '✓ ' For Parallel/ADEMCO emulation: Select group number. Enter 2 digit number. Press '✓ ' CONFIGURE : EVENT GROUPS (Remove) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 51 CONFIGURE : EVENT GROUPS (Remove) continued ┌───────┴────────┐ │REMOVE [type ]│ │Event Group │ │Enter No: xxxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE [type ]│ │Event Group nnnn│ │Press YES or NO │ │ │ └────────────────┘ For Serial Event Reporting: Select group number. Enter 4 digit number. Press '✓ ' Display of group number for confirmation Press '✓ ' to remove Press 'X' to retain Returns to menu if successful EVENT GROUPS (View) ┌────────────────┐ ♦│ │EVENT GROUPS │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW GROUP ♦│ │1 Primary │ │2 Secondary │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW [type ]│ │Event Group │ │Enter No: xx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW [type ]│ │Event Group │ │Enter No: xxxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW [type ]│ │Group No: nnnn │ │[priority ]│ │Events │ └───────┬────────┘ [priority ] Low priority High priority <-- Select 'View' Select primary or secondary. Use '▲' or '▼'to scroll required type to line 2. Press '✓ ' For Parallel/ADEMCO emulation: Select group number. Enter 2 digit number. Press '✓ ' For Serial Event Reporting: Select group number. Enter 4 digit number. Press '✓ ' Display of priority. Press '✓ ' to continue ┌───────┴────────┐ │VIEW [type ]│ Display of group events. │Group nnnn │ Press '✓ ' to continue │[message ]│ │[message ]│ └────────────────┘ [message ] As in CONFIGURE : EVENT GROUPS (Add) and including 'Hist log events' 52 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : REMOTE COMMS (SERIAL EQUIPMENT) Configure type of serial equipment and mode of operation. Monitor Line facility The health of the telephone line connection is periodically checked. Session Time-out The maximum time for which an idle connection is retained since the last communication. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Remote Comms │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOTE COMMS ♦│ │.. │ │. Serial Equip. │ │.. │ └────────────────┘ <-- Select 'System' <-- Select 'Remote Comms' <-- Select 'Serial Equip.' SERIAL EQUIPMENT (Modify) ┌────────────────┐ │SERIAL │ │EQUIPMENT ♦│ │. Modify │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MODIFY │ │EQUIPMENT ♦│ │Port number: x │ │ │ └───────┬────────┘ ┌───────┴────────┐ │SERIAL PORT N │ │Communicator: ♦│ │[type menu line]│ │[type menu line]│ └────────────────┘ [type menu line ] . not used . ChubbCOM . PAD . V.25bis . Hayes . Hayes HDX . WindsorModem . Wmodem HDX . INOVA . Direct <-- Select 'Modify' Select serial port. Enter 1 digit number. Press '✓ ' The range is 1 to 2 unless a four serial port mezzanine board is present, when it is 1 to 6. Select communicator type (or none). Use '▲' or '▼' to scroll required communicator to line 3. Press '✓ ' Note: For 'Hayes' and 'V.25bis the device connected must be: 8 data bits, No parity, 1 stop bit ‘HDX’ - Half Duplex CONFIGURE : SERIAL EQUIPMENT (Modify) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 53 CONFIGURE : SERIAL EQUIPMENT (Modify) continued ┌───────┴────────┐ │SERIAL PORT x │ │Protocol: ♦│ │[prot menu line]│ │[prot menu line]│ └────────────────┘ [prot menu line ] . PS/006 . PS/018 . PS/024 ┌───────┴────────┐ │SERIAL PORT x │ │Data rate: ♦│ │[rate menu line]│ │[rate menu line]│ └────────────────┘ [rate menu line ] . 1200 . 2400 . 4800 . 9600 . 19200 . 38400 ┌───────┴────────┐ │SERIAL PORT x │ │Monitor Line is │ │[status ]│ │Change?YES or NO│ └────────────────┘ [status ] ENABLED DISABLED ┌───────┴────────┐ │SERIAL PORT x │ │Session Timeout │ │xx:xx hh:mm │ │ │ └───────┬────────┘ ┌───────┴────────┐ │SERIAL PORT x │ │Port address │ │000.000.000.000 │ │ │ └───────┬────────┘ ┌───────┴────────┐ │SERIAL PORT x │ │Router address │ │000.000.000.000 │ │ │ └───────┬────────┘ ┌───────┴────────┐ │SERIAL PORT x │ │Subnet mask │ │000.000.000.000 │ │ │ └────────────────┘ If protocol is variable: Select data protocol Use '▲' or '▼' to scroll required protocol to line 3. Press '✓ ' Select data rate Use '▲' or '▼' to scroll required baud rate to line 3. Press '✓ ' If not INOVA: Specify Monitor Line facility. Press '✓ ' to change displayed status Press 'X' to retain displayed status Specify Session time-out period. Select 2 digit hour. Press '✓ ' Select 2 digit minute. Press '✓ ' If zero, the session does not time out. For IP network applications: Specify the Port IP address. Enter 4 3-digit numbers. Press '✓ ' Specify the Router IP address. Enter 4 3-digit numbers. Press '✓ ' Specify the subnet mask. Enter 4 3-digit numbers. Press '✓ ' Returns to menu if successful CONFIGURE : SERIAL EQUIPMENT (View) overleaf 54 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : SERIAL EQUIPMENT continued SERIAL EQUIPMENT (View) ┌────────────────┐ │SERIAL │ │EQUIPMENT ♦│ │.. │ │. View │ └───────┬────────┘ ┌───────┴────────┐ │VIEW │ │EQUIPMENT │ │Port number: x │ │ │ └───────┬────────┘ ┌───────┴────────┐ │SERIAL PORT N │ │[comm. type ]│ │[protocol ]│ │[baud rate ]│ └───────┬────────┘ [comm. type ] not used ChubbCOM PAD V.25bis Hayes Hayes HDX WindsorModem WModem HDX INOVA Direct ┌───────┴────────┐ │SERIAL PORT N │ │[mon. facility ]│ │Session Timeout │ │ H:MM hh:mm │ └────────────────┘ [mon. facility ] Monitor Line No Monitor Line <-- Select 'View' Select serial port. Select number. Press '✓ ' Display of Display of Display of Press '✓ ' communicator type serial port baud rate line monitor facility to continue [protocol not used PS/006 PS/018 PS/024 ] [baud rate 0 bps 1200 bps 2400 bps 4800 bps 9600 bps 19200 bps 38400 bps ] Display of session time-out Press '✓ ' to continue Returns to menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 55 CONFIGURE : RESPONSES Configure sounders/strobes delays and duration. Some point types such as NA2 and PA1 only activate the local sounder if a line fault is detected when the alarm occurs, or if a communication failure is detected within the latent period following the alarm. Configure the period over which mains fail should be detected before a Mains Fail alarm is generated. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Responses │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SOUNDER DELAY │ │xx - minutes │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │SOUNDER DURATION│ │xx - minutes │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │STROBE DELAY │ │xx - minutes │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │STROBE DURATION │ │xx - minutes │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │LATENT PERIOD │ │xx - minutes │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │PREWARN DURATION│ │xxxx - seconds │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │MAINS FAIL DELAY│ │xx - minutes │ │ │ │ │ └────────────────┘ 56 <-- Select 'System' <-- Select 'Responses' Specify sounder delay. Enter 2 digit number (mins). Press '✓ ' Specify sounder duration. Enter 2 digit number (mins). Press '✓ ' 00 = Continuous Specify strobe delay. Enter 2 digit number (mins). Press '✓ ' Specify strobe duration. Enter 2 digit number (mins). Press '✓ ' 00 = Continuous Specify latent period. Enter 2 digit number (mins). Press '✓ ' Specify prewarning duration. Enter 4 digit number (secs). Press '✓ ' Specify period before Mains Fail alarm. Enter 2 digit number (mins). Press '✓ ' Returns to 'MODIFY SYSTEM' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : SCHEDULE Schedules control when zones may be unset and when they must be set. Each zone may be controlled by one or more schedules. If a zone is not controlled by any schedules it may be set and unset at any time. Otherwise the zone may only become unset while at least one of its controlling schedules are in an open window. While at least one of its controlling schedules are open (but none are in an open window) the zone may remain set or unset, it may become set, but once it is set the zone cannot become unset. While all of a zone's controlling schedules are closed, the zone must become or remain set, it may not become or remain unset. Normally the open window of a schedule starts at the earliest normal opening and ends at the latest normal opening, the schedule is then open until the latest normal closing, it is then closed until the following earliest normal opening. The early open feature may be used to bring the start of the open window forward (see User Manual). The start of the open window cannot be bought forward any further than the earliest early opening. Similarly late working delays the when the schedule becomes shut. This can not be delayed any further that the latest late working. If all five times above are set to zero, the schedule is closed all day. SCHEDULE (Add) ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. Schedule │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE S ♦│ │ssssssssssssssss│ │Press YES to │ │select │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE S │ │Controls zone ZZ│ │zzzzzzzzzzzzzzzz│ │Press YES or NO │ └───────┬────────┘ │ ┌───────┴────────┐ │SCHEDULE S │ │[day ]│ │Earliest early │ │opening:- xx:xx │ └────────────────┘ [day ] Monday Tuesday Wednesday Thursday Friday Saturday Sunday <-- Select 'Schedule' Specify schedule number. Use '▲' or '▼' to scroll number. Press '✓ ' Specify zone(s) to be controlled by the schedule. Press '✓ ' to select zone Press 'X' to reject zone Repeat for all zones Repeat for each day: Specify Earliest early opening. Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min.). Press '✓ ' If not required the time must be set to the same as normal opening. CONFIGURE : SCHEDULE (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 57 CONFIGURE : SCHEDULE (Add) continued ┌───────┴────────┐ │SCHEDULE S │ │[day ]│ │Earliest normal │ │opening:- xx:xx │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE S │ │[day ]│ │Latest normal │ │opening:- xx:xx │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE S │ │[day ]│ │Latest normal │ │closing:- xx:xx │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE S │ │[day ]│ │Latest late │ │working:- xx:xx │ └───────┬────────┘ │ │ │ ┌───────┴────────┐ │SCHEDULE S │ │Enter descriptor│ │♦ │ │ │ └────────────────┘ Specify Earliest normal opening. Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min.). Press '✓ ' Specify Latest normal opening. Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min.). Press '✓ ' Specify Latest normal closing. Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min.). Press '✓ ' Specify Latest late working. Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min.). Press '✓ ' If not required the time must be set to the same as normal closing. The above repeats for each day to be specified. Specify schedule descriptor. Select characters (see USING THE KEYPAD) Returns to 'Log-On' NOTES ┌────────────────┐ │SCHEDULE ERROR │ │Overlapping │ │time settings │ │ │ └────────────────┘ A mistake in data entry. For example Latest Normal Opening is before Earliest Normal Opening. CONFIGURE : SCHEDULE continued overleaf 58 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : SCHEDULE continued SCHEDULE (Modify) ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. Schedule │ <-│.. │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE S │ │ssssssssssssssss│ │Press YES to │ │select │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE ♦│ │.. │ │. Modify │ <-│.. │ └───────┬────────┘ │ .............continue as Select 'Schedule' Specify schedule. Use '▲' or '▼' to scroll required schedule to line 2. Press '✓ ' Select 'Modify' for SCHEDULE (Add) SCHEDULE (Remove) ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. Schedule │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE S │ │ssssssssssssssss│ │Press YES to │ │select │ └───────┬────────┘ ┌───────┴────────┐ │SCHEDULE ♦│ │.. │ │. Remove │ │.. │ └────────────────┘ <-- Select 'Schedule' Specify schedule. Use '▲' or '▼' to scroll required schedule to line 2. Press '✓ ' <-- Select 'Remove' Returns to 'Log-On' if successful Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 59 CONFIGURE : START/END CONFIGURATION The behaviour of the Windsor 700 is largely controlled by its configuration. The configuration will usually be created using the Windsor 700 Configuration Editor PC software. The configuration is then transferred to the Windsor 700 either using a PROM Pack (See CONFIGURE : COPY CONFIGURATION) or a GuardStation (See CONFIGURE : REMOTE CONFIGURATION). The configuration may be altered (or in an emergency created) at the keypad. Before altering the configuration, the Windsor 700 must be put into configuration mode using the following procedure. Note that while the Windsor 700 is in configuration mode, it is unable to monitor alarms and all other keypads are disabled. . CONFIGURATION (Start) ┌────────────────┐ │FUNCTION SELECT♦│ │. .. │ │. Configuration │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │Command Disables│ │*** Panel ***│ │Press NO = Quit │ │YES = Continue │ └────────────────┘ <-- Select 'Configuration' Note that the system is no longer able to monitor alarms if the function is continued. Press '✓ ' to continue Press 'X' to abort If successful the 'CONFIG MENU' is presented. Continue according to requirement then perform 'End' as described overleaf. NOTES ┌────────────────┐ │CONFIG FAIL │ │System set or │ │partially set │ │ │ └────────────────┘ Set zones will prevent the configuration examination/modification. The zones must be unset to continue. Press 'C' ┌────────────────┐ │Configuration │ │disable │ │Other users │ │logged on │ └────────────────┘ Other users are logged-on. or a remote user is logged-on. This prevents configuration examination. Press 'C' ┌────────────────┐ │Configuration │ │disable │ │Comms in use │ │Press CLEAR │ └────────────────┘ The comms link is in use. This prevents configuration examination. Press 'C' CONFIGURE : START/END CONFIGURATION continued overleaf 60 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : START/END CONFIGURATION continued CONFIGURATION (End) ┌────────────────┐ ♦│ │CONFIG MENU │. .. │ │. END Config │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │ END │ │ CONFIGURATION │ │checking config │ │please wait │ └───────┬────────┘ ┌───────┴────────┐ │ CONFIG NUMBER │ │*xxxxxx-y* │ │ YES key to │ │ continue │ └───────┬────────┘ ┌───────┴────────┐ │Re-initialising │ │System Please │ │ WAIT │ │ │ └────────────────┘ <-- Select 'END Config' The configuration is checked for anomalies For small configurations, this may be displayed only for a short time. If configuration is acceptable: Display of updated version number xxxxxx is the site i.d. and may be changed y is the config. version and may not be changed. Press '✓ ' to continue Wait for the system to re-initialise with the new configuration. The display will clear and then return to 'FUNCTION SELECT' menu if successful NOTES ┌────────────────┐ │ CONFIGURATION │ │ ERROR │ │[error line 1 ]│ │[error line 2 ]│ └────────────────┘ ┌────────────────┐ │CONFIGURATION │ │IS TOO LARGE │ │Press CLEAR to │ │return │ └────────────────┘ ┌────────────────┐ │ Limited maximum│ │ no. of users xx│ │ INFORM MASTER │ │Press CLEAR │ └────────────────┘ There are a large number of error messages associated with this display. The error must be corrected. Press 'C' to return to menu The configuration is too large for the storage device which is fitted on the Control Unit PCB. The device will require substitution or the configuration must be reduced. Press 'C' to return to menu The configuration data has filled the storage device to the extent that the space remaining to hold user data is restricted and the number of users will hence be limited as displayed. Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 61 CONFIGURE : UI This facility enables the programming of devices which connect to the User Interface Network (UIN). Disabled in a set zone The display will be blank. Pressing a key will un-blank the display and the user may log-in. Disabled in an unset zone The display will be blank but in this instance attempted use by pressing a key will have no effect. This facility is primarily intended for ATM bypass. A card reader can be attached to one or more keypads. This can be used to grant access to an ATM lobby when a valid card is swiped (see CONFIGURE : LOBBY ACCESS for how to set up valid cards) or alternatively to provide access card log-on (see the User Manual for how to setup valid user cards). When configuring a keypad you must specify whether a lobby card reader is attached. If so, you must specify which point output is linked to the lobby door strike and for how long the door must be opened when a card is swiped. The point output must be configured to react to some point, zone, or system condition. Usually it will be configured as a monitor point linked to a signalling point input. this point input is then wired to a request to exit button. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. UI Port │ │.. │ └────────────────┘ <-- Select 'UI Port' UI (Add) ┌────────────────┐ ♦│ │UI PORT │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │UI PORT │ │Enter address-x │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │UI PORT K │ │Enter descriptor│ │♦ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │UI PORT K │ │Select type │ │[UI type menu ]│ │ │ └───────┬────────┘ [UI type menu ] . normal <-- Select 'Add' Specify address of UI. Enter 1 digit number. Press '✓ ' Specify descriptor of UI. Select characters (see USING THE KEYPAD) Specify type of UI. Use '▲' or '▼' to scroll required UI type to line 3. Press '✓ ' CONFIGURE : UI (Add) continued overleaf 62 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : UI (Add) continued ┌───────┴────────┐ │UI PORT K │ │[zone state] ZZ │ │zzzzzzzzzzzzzzzz│ │Change?YES or NO│ └───────┬────────┘ [zone state ] Controls zone NOT for zone ┌───────┴────────┐ │UI PORT K │ │[set line 1 ]│ │in set zone │ │Change?YES or NO│ └───────┬────────┘ [set line 1 ] UI Disabled when UI Enabled when ┌───────┴────────┐ │UI PORT K │ │[unset line 1 ]│ │in unset zone │ │Change?YES or NO│ └───────┬────────┘ [unset line 1 ] UI Enabled when UI Disabled when ┌───────┴────────┐ │UI PORT K │ │[line 2 ]│ │ │ │Change?YES or NO│ └───────┬────────┘ [line 2 ] No Set/Uns Menu Set/Unset Menu ┌───────┴────────┐ │UI PORT K │ │[key message ]│ │Change?YES or NO│ │ │ └───────┬────────┘ [key message ] UI with key no keyswitch ┌───────┴────────┐ │UI PORT K │ │Card Login │ │[line 3 ]│ │Change?YES or NO│ └───────┬────────┘ [line 3 ] Disabled Enabled Specify zone(s) to be controlled by UI. Press '✓ ' to change displayed status Press 'X' to retain displayed status Repeats for all zones If the UI is disabled when all its zones are set, the display will be blanked. In this state, pressing a key unblanks the display and the user may log-in. Press '✓ ' to change displayed status Press 'X' to retain displayed status If the UI is disabled when all its zones are unset the display will be blanked. In this state, pressing a key will have no effect. Press '✓ ' to change displayed status Press 'X' to retain displayed status Specify whether UI has set/unset menu. Press '✓ ' to change displayed status Press 'X' to retain displayed status Specify whether UI has keyswitch. Press '✓ ' to change displayed status Press 'X' to retain displayed status Specify whether UI has card reader for log-on. Press '✓ ' to change displayed status Press 'X' to retain displayed status CONFIGURE : UI (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 63 CONFIGURE : UI (Add) continued ┌───────┴────────┐ │UI PORT K │ │Lobby access │ │[access status ]│ │Change?YES or NO│ └───────┬────────┘ [access status ] Disabled Enabled ┌───────┴────────┐ │UI PORT K │ │Door strike on │ │point xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │UI PORT K │ │Door open for │ │xx seconds │ │ │ └────────────────┘ Specify whether UI has lobby access. Press '✓ ' to change displayed status Press 'X' to retain displayed status If you select this then card reader log-on is disabled. If lobby access enabled: Specify point output controlling lobby door. Enter 3 digit number. Press '✓ ' Specify duration of point output (0 to 99s) Enter 2 digit number (01 to 99). Press '✓ ' Returns to 'UI NETWORK DEF' menu NOTES 'invalid number' The number selected is out-of-range or the number has already been allocated. UI (Modify) ┌────────────────┐ ♦│ │UI PORT │.. │ │. Modify │ <-- Select 'Modify' │.. │ └───────┬────────┘ │ .............continue as for UI (Add) UI (Remove) ┌────────────────┐ ♦│ │UI PORT │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │UI PORT │ │Enter address-x │ │ │ │ │ └───────┬────────┘ <-- Select 'Remove' Specify UI Address. Enter 1 digit number. Press '✓ ' CONFIGURE : UI (Remove) continued overleaf 64 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : UI (Remove) continued ┌───────┴────────┐ │REMOVE UI K │ │kkkkkkkkkkkkkkkk│ │Press YES or NO │ │ │ └────────────────┘ Display of UI descriptor for confirmation. Press '✓ ' to remove Press 'X' to abort Returns to 'CONFIG MENU' if successful UI (View) ┌────────────────┐ ♦│ │UI PORT │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │UI PORT │ │Enter address-x │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW UI PORT K │ │kkkkkkkkkkkkkkkk│ │[key status ]│ │[set/unset menu]│ └────────────────┘ [key status ] keyswitch fitted No keyswitch ┌───────┴────────┐ │VIEW UI PORT K │ │[set status ]│ │controllable │ │zones are set │ └───────┬────────┘ [set status ] Enabled when Disabled when ┌───────┴────────┐ │VIEW UI PORT K │ │[unset status ]│ │controllable │ │zones are unset │ └───────┬────────┘ [unset status ] Enabled when Disabled when ┌───────┴────────┐ │VIEW UI PORT │ │Controllable │ │zone ZZ ♦│ │zzzzzzzzzzzzzzzz│ └───────┬────────┘ <-- Select 'View' Specify UI Address. Enter 1 digit number. Press '✓ ' Display of UI descriptor. Display of keyswitch status. Press '✓ ' to continue [set, unset menu ] No Set/Uns menu Set/Unset menu Display of activity in set zones. Press '✓ ' to continue Display of activity in unset zones. Press '✓ ' to continue Display of zones controlled by UI. Use '▲' or '▼' to scroll zone list Press '✓ ' to continue CONFIGURE : UI (View) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 65 CONFIGURE : UI (View) continued ┌───────┴────────┐ │VIEW UI PORT K │ │Card login │ │[card status ]│ │ │ └───────┬────────┘ [card status ] Enabled Disabled ┌───────┴────────┐ │VIEW UI PORT │ │[access line 1 ]│ │[access line 2 ]│ │[access line 3 ]│ └────────────────┘ [access line 1 ] Lobby access No Lobby access 66 Display of swipe card login facility. Press '✓ ' to continue Display of zones controlled by UI. Press '✓ ' to continue Returns to menu [access line 2 ] Door point OOO Guardall Ltd [access line 3 Open NN secs ] Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : ZONE This facility enables the creation or modification of a zone, the removal of a zone from the configuration or provides information on the zone(s) already configured. Normal Secure Special secure ATM Bypass The default zone type. A zone which is always set and cannot be unset. This zone type is obsolete and should not be used. A zone with one or more ATMs which may be accessed using the ATM Bypass feature. Max number of isolated points This number must be less, by at least one, than the number of isolatable points in the zone. This number must be less, by at least one, than the number of shuntable points in the zone. Max number of shunted points Linked for set ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. Zone │ │.. │ └────────────────┘ Zones which will be set when this one is set. If setting of any of these zones would cause an alarm, then none of the zones are set, including this one. <-- Select 'Zone' ZONE (Add) ┌────────────────┐ ♦│ │ZONE │.. │ │. Add │ │.. │ └────────┬───────┘ ┌────────┴───────┐ │ADD ZONE │ │Enter number:-xx│ │ │ │ │ └────────┬───────┘ ┌────────┴───────┐ │ADD ZONE ZZ │ │Enter descriptor│ │♦ │ │0=complete │ └────────┬───────┘ ┌────────┴───────┐ │ADD ZONE ZZ │ │Define type ♦│ │[zone type menu]│ │[zone type menu]│ └────────┬───────┘ [zone type menu ] . Normal . Special secure . ATM Bypass <-- Select 'Add zone' Specify zone number. Enter 2 digit number. Press '✓ ' Specify zone descriptor. Select characters (see USING THE KEYPAD) Specify zone type. Use '▲' or '▼' to scroll required type to line 3. Press '✓ ' CONFIGURE : ZONE (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 67 CONFIGURE : ZONE (Add) continued ┌────────┴───────┐ │ADD ZONE ZZ │ │Specify entry │ │exit route:- xx │ │ │ └────────┬───────┘ ┌────────┴───────┐ │MAX NUMBER OF │ │isolated points │ │:- xxx │ │ │ └────────┬───────┘ ┌────────┴───────┐ │MAX NUMBER OF │ │shunted points │ │:- xxx │ │ │ └────────┬───────┘ ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │Auto Set/Unset │ │Change?YES or NO│ └────────┬───────┘ [line 2 ] Manual and NOT Manual and ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │Schedule expiry │ │Change?YES or NO│ └────────┬───────┘ [line 2 ] Automatic Set on NOT Set on ┌───────┴────────┐ │ADD ZONE ZZ │ │[line 2 ]│ │[line 3 ]│ │Change?YES or NO│ └────────┬───────┘ [line 2 ] Automatic Unset NOT automatic ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │[line 3 ]│ │Change?YES or NO│ └────────┬───────┘ [line 2 ] NOT Restricted Restricted Unset Specify Entry/Exit route. Enter 2 digit number. Press '✓ ' [0 = no route] Specify maximum number of isolatable points. Enter 3 digit number. Press '✓ ' Specify maximum number of shuntable points. Enter 3 digit number. Press '✓ ' Specify if this scheduled zone can be manually set or unset outside the schedule. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. Specify if zone is to be automatically set when a schedule expires. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. Specify if zone is to be automatically unset when a schedule opens. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. [line 3 at open time unset ] Specify if zone may only be unset once within an open window. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. [line 3 Unset in open window ] CONFIGURE : ZONE (Add) continued overleaf 68 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : ZONE (Add) continued ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │Set/Unset Menu │ │Change?YES or NO│ └────────┬───────┘ [line 2 ] Show zone on Hide zone on ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │controller │ │Change?YES or NO│ └────────┬───────┘ [line 2 ] NOT ATM ATM ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │Change?YES or NO│ │ │ └────────┬───────┘ [line 2 ] NOT secure zone secure zone ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │PIN Response │ │Change?YES or NO│ └────────┬───────┘ [line 2 ] No Invalid Invalid ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │Change?YES or NO│ │ │ └────────┬───────┘ [line 2 ] No linked zones Linked zones ┌────────┴───────┐ │ADD ZONE ZZ │ │Link to Zone ZZ │ │zzzzzzzzzzzzzzzz│ │Press YES or NO │ └────────┬───────┘ Specify if zone will be displayed in the Set/ Unset menu. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. If a Normal zone: Specify if zone is an ATM control zone. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. Specify if zone is to be a secure zone. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. If Keypad Alarm configured: Specify if zone is to be Invalid PIN unset. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. Specify if zone has any "linked for set" zones. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. If linked zones specified above: Specify which zones are to be linked to this zone for set. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. CONFIGURE : ZONE (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 69 CONFIGURE : ZONE (Add) continued ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │cmd restricted │ │Change?YES or NO│ └────────┬───────┘ [line 2 ] Zone is NOT Zone is ┌────────┴───────┐ │ADD ZONE ZZ │ │[line 2 ]│ │dual PIN access │ │Change?YES or NO│ └────────┬───────┘ [line 2 ] Zone is NOT Zone is ┌────────┴───────┐ │ADD ZONE ZZ │ │Rearm delay in │ │seconds: xxx │ │ │ └────────┬───────┘ ┌────────┴───────┐ │ADD ZONE ZZ │ │AutoUnshunt │ │[unshunt status]│ │Change?YES or NO│ └────────────────┘ [unshunt status ] Enabled Disabled Specify whether selected commands are to have no access to this zone. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. Specify whether zone is to be unset using dual PIN entry. Press 'X' to retain displayed status. Press '✓ ' to change displayed status. Specify rearm delay time. Enter 3 digit number (000 to 255). Press '✓ ' (000 for rearm disabled) If Autorearm configured: Specify if autounshunt required Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to 'ZONE' menu NOTES 'Add zone' not in menu Maximum number of zones already configured. 'invalid number' The number is out-of-range, or the number has already been assigned. For isolated and shunt limits see INTRODUCTION. ZONE (Modify) ┌────────────────┐ ♦│ │ZONE │.. │ │. Modify │ <-- Select 'Modify' │.. │ └───────┬────────┘ │ .............continue as for ZONE (Add) NOTES 'Change zone' not in menu No zones are currently configured. CONFIGURE : ZONE continued overleaf 70 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : ZONE continued ZONE (Remove) ┌────────────────┐ ♦│ │ZONE │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE ZONE │ │Enter number:-xx│ │ │ │ │ └────────────────┘ <-- Select 'Remove' Specify zone number. Enter 2 digit number. Press '✓ ' Returns to 'ZONE' menu if successful NOTES 'Remove zone' not in menu No zones already configured. 'invalid number' The number is out-of-range, or the number has not been assigned. ZONE (View) ┌────────────────┐ ♦│ │ZONE │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW ZONE xx ♦│ │zzzzzzzzzzzzzzzz│ │zzzzzzzzzzzzzzzz│ │zzzzzzzzzzzzzzzz│ └───────┬────────┘ ┌───────┴────────┐ │VIEW ZONE ZZ │ │zzzzzzzzzzzzzzzz│ │[zone type ]│ │E/E route - E │ └────────────────┘ [zone type ] see ZONE (Add) ┌───────┴────────┐ │VIEW ZONE ZZ │ │Max shunts -nnn│ │Max isolates-nnn│ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW ZONE ZZ │ │Pt III in zone ♦│ │iiiiiiiiiiiiiiii│ │ │ └───────┬────────┘ <-- Select 'View' Specify zone number or scroll to required zone. Press '✓ ' Display of Display of Display of Press '✓ ' zone descriptor. zone type. Entry/Exit Route. to continue Display of number of shuntable points. Display of number of isolatable points. Press '✓ ' to continue Display of point inputs in zone. Use '▲' or '▼' to scroll CONFIGURE : ZONE (View) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 71 CONFIGURE : ZONE (View) continued ┌───────┴────────┐ │VIEW ZONE ZZ │ │[line 2 ]│ │Auto Set/Unset │ │ │ └───────┬────────┘ [line 2 ] Manual and NOT Manual and ┌───────┴────────┐ │VIEW ZONE ZZ │ │[Unset fct ]│ │[Set fct ]│ │on Sched expiry │ └────────────────┘ [Unset fct ] Auto Unset NOT Auto Unset ┌───────┴────────┐ │VIEW ZONE ZZ │ │[line 2 ]│ │[line 3 ]│ │ │ └───────┬────────┘ [line 2 ] NOT Restricted Restricted Unset ┌───────┴────────┐ │VIEW ZONE ZZ │ │[line 2 ]│ │Set/Unset Menu │ │ │ └───────┬────────┘ [line 2 ] Show Zone on Hide Zone on ┌───────┴────────┐ │VIEW ZONE ZZ │ │[line 2 ]│ │controller │ │ │ └───────┬────────┘ [line 2 ] NOT ATM ATM ┌───────┴────────┐ │VIEW ZONE ZZ │ │[line 2 ]│ │ │ │ │ └───────┬────────┘ [line 2 ] NOT secure zone secure zone Display whether this scheduled zone can be manually set or unset outside the schedule. Press '✓ ' to continue Display of Unset function. Display of Set function. Press '✓ ' to continue [Set fct Automatic Set NOT Set ] Display of whether zone may only be unset once within an open window. Press '✓ ' to continue [line 3 Unset in open window ] Display of whether zone will be displayed in the Set/Unset menu. Press '✓ ' to continue Only displayed for a Normal zone. Display of whether zone is an ATM control zone. Press '✓ ' to continue Display whether zone is a secure zone. Press '✓ ' to continue CONFIGURE : ZONE (View) continued overleaf 72 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F CONFIGURE : ZONE (View) continued ┌───────┴────────┐ │VIEW ZONE ZZ │ │Linked zone ZZ │ │zzzzzzzzzzzzzzzz│ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW ZONE ZZ │ │[line 2 ]│ │cmd restricted │ │ │ └───────┬────────┘ [line 2 ] Zone is NOT Zone is ┌───────┴────────┐ │VIEW ZONE ZZ │ │[line 2 ]│ │dual PIN access │ │ │ └───────┬────────┘ [line 2 ] Zone is NOT Zone is ┌───────┴────────┐ │VIEW ZONE ZZ │ │Rearm delay in │ │seconds: xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW ZONE ZZ │ │AutoUnshunt │ │[unshunt status]│ │ │ └────────────────┘ [unshunt status ] Enabled Disabled Only displayed if slave zones are defined: Display zones linked to this zone for set. Use '▲' or '▼' to scroll Press '✓ ' to continue Display whether selected commands are to have no access to this zone. Press '✓ ' to continue Display whether zone is to be unset by dual PIN access. Press '✓ ' to continue Display of rearm delay. Press '✓ ' to continue If Autorearm configured: Display whether autounshunt defined Press '✓ ' to continue Returns to 'ZONE' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 73 DEFINE : ACPO MODE This facility is used to clear a remote communications activation if the user logs-on and unsets those zones in alarm. The Central Station will, for ACPO requirements, ignore alarms if they are cleared within x minutes. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. ACPO Tx reset │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ACPO TX RESET │ │[ACPO status ]│ │compliant │ │Change YES or NO│ └────────────────┘ [ACPO status ] Panel is ACPO Panel not ACPO 74 <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'ACPO Mode' Specify requirement for ACPO Mode. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status Returns to 'MISC SYS PARAMS' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : ATM TIMES The ATM bypass facility allows a zone to be temporarily unset to allow the replenishment of an ATM. Each zone which protects such an ATM must be configured as an ATM bypass zone, see CONFIGURE : ZONES. The ATM bypass is controlled either from a dedicated keypad which is only in the ATM zone, or from a non-dedicated keypad that has access to one or more ATM zones when any ATM control zone is set. At a dedicated ATM keypad the user will enter a PIN. If the PIN entry wait period is non-zero, the PIN has to be re-entered after waiting for the specified time. After replenishing the ATM, the PIN is entered and "Bypass Remove" selected. If the bypass is not removed within the access period, the bypass will automatically be removed (if the user is still present an alarm will be cause). If the user runs out of time the bypass can be renewed up to access period repeat times by re-entering the PIN and selecting "Extend Bypass". At a non-dedicated keypad with ATM Bypass capability, only the access period and access period repeat fields are used. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. ATM Times │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEFINE ATM TIMES│ │PIN entry wait │ │period : xx mins│ │ │ └───────┬────────┘ ┌───────┴────────┐ │DEFINE ATM TIMES│ │PIN entry period│ │: xxx seconds │ │ │ └───────┬────────┘ ┌───────┴────────┐ │DEFINE ATM TIMES│ │Access period │ │: xx minutes │ │ │ └───────┬────────┘ ┌───────┴────────┐ │DEFINE ATM TIMES│ │Access period │ │repeat no : xx │ │ │ └────────────────┘ <-- Select 'System' <-- Select 'Def Time Param' <-- Select 'ATM Times' Specify time for PIN 'validation' Enter 2 digit number (00 to 99). Press '✓ ' Only displayed if PIN entry wait period > 0 Specify time-out for PIN re-entry Enter 3 digit number (010 to 120). Press '✓ ' Specify ATM zone access time. Enter 2 digit number (12 to 60). Press '✓ ' Specify number of times extended time may be requested. Enter 2 digit number (01 t0 10). Press '✓ ' Returns to 'DEF TIME PARAMs' menu NOTES 'invalid number' Windsor 700 Service Manual V8.4 Iss.0F The selected number is out-of-range. Guardall Ltd 75 DEFINE : AUTO. BATTERY TEST This option allows the configuration of an automatic battery test which is to occur at configurable times. The test is then performed automatically at these times regardless of the set/unset status of the system. If the test fails it will not be possible to set the system. A configurable remote comms event will be reported. Any zones which are unset, unsetting or setting will be put into prewarning. The test times can be configured in one of two ways: Daily The test will run at the configured time on the specified day. Periodically The test will run on the specified day at times separated by the configured period with the first test at the specified period after 00:00 (midnight). For example, if the configured period is 07:00 the test will run at 07.00, 14.00, and 21.00. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. Timed function│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCTION │ │Enter number: x │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T ♦│ │.. │ │. Battery test │ │.. │ └────────────────┘ <-- Select 'System' <-- Select 'Def Sys Param' <-- Select 'Timed function' Specify number of timed function. Enter 1 digit number (1 to 4). Press '✓ ' <-- Select 'Battery test' AUTO. BATTERY TEST (Daily) ┌────────────────┐ │TIMED FUNCT. T ♦│ │.. │ │. Daily │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] │ │no test ♦│ │Change?YES or NO│ └───────┬────────┘ [day ] Monday ... Sunday <-- Select 'Daily' If 'no test' for the day Press '✓ ' to change from no test Press 'X' to retain no test DEFINE : AUTO. BATTERY TEST continued overleaf 76 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : AUTO. BATTERY TEST continued ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] at │ │hh:mm │ │ │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] at │ │hh:mm ♦│ │Change?YES or NO│ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] at │ │hh:mm │ │ │ └────────────────┘ If change requested from 'no test': Specify days and times for test Press '▲' to display hours and minutes. Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min). Press '✓ ' If displayed time for the day Press '✓ ' to change from no test Press 'X' to retain no test If change requested from displayed time: Specify days and times for test Press '▲' if no test required. Press '✓ ' Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min). Press '✓ ' Returns to 'DEF TIME PARAMs' menu AUTO. BATTERY TEST (Periodically) ┌────────────────┐ │TIMED FUNCT. T ♦│ │.. │ │. Periodically │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] every │ │ h:mm │ │Change?YES or NO│ └───────┬────────┘ [day ] Monday ... Sunday ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] every │ │hh:mm │ │ │ └────────────────┘ <-- Select 'Periodically' Specify days and period interval for test Press '✓ ' to change the displayed period Press 'X' to retain the displayed period Repeat for all days If change requested: Specify days and times for test Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min). Press '✓ ' Returns to 'DEF TIME PARAMs' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 77 DEFINE : AUTO. BELL MUTE This facility enables a user to mute the system bells when logging-on. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Auto Bell Mute│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARAM │ │Auto Bell Mute │ │[status ]│ │Change?YES or NO│ └────────────────┘ [status ] Enabled Disabld 78 <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Auto Bell Mute' Specify requirement for Auto Bell Mute. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status Returns to 'MISC SYS PARAMS' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : AUTO. DETECTOR TEST Those detectors which have a self test capability can be automatically tested. This option specifies time(s) for the test and the zone(s) within which it is to be performed. The test times can be configured in one of two ways: Daily The test will run at the configured time on the specified day. Periodically The test will run on the specified day at times separated by the configured period with the first test at the specified period after 00:00 (midnight). For example, if the configured period is 07:00 the test will run at 07.00, 14.00, and 21.00. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. Timed function│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCTION │ │Enter number: x │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T ♦│ │.. │ │. Detector test │ │.. │ └────────────────┘ <-- Select 'System' <-- Select 'Def Sys Param' <-- Select 'Timed function' Specify number of timed function. Enter 1 digit number (1 to 4). Press '✓ ' <-- Select 'Detector test' AUTO. DETECTOR TEST (Daily) ┌────────────────┐ │TIMED FUNCT. T ♦│ │.. │ │. Daily │ │.. │ └───────┬────────┘ │ ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] │ │no test ♦│ │Change?YES or NO│ └───────┬────────┘ [day ] Monday ... Sunday <-- Select 'Daily' Specify days and times for test If 'no test' for the day Press '✓ ' to change from no test Press 'X' to retain no test DEFINE : AUTO. DETECTOR TEST (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 79 DEFINE : AUTO. DETECTOR TEST (Add) continued ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] at │ │hh:mm │ │ │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] at │ │hh:mm ♦│ │Change?YES or NO│ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] at │ │hh:mm │ │ │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[stat] zone ZZ │ │[status ] │ │Change?YES or NO│ └────────────────┘ [stat ] in NOT in If change requested from 'no test': Specify days and times for test Press '▲' to display hours and minutes. Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min). Press '✓ ' If displayed time for the day Press '✓ ' to change from no test Press 'X' to retain no test If change requested from displayed time: Specify days and times for test Press '▲' if no test required. Press '✓ ' Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min). Press '✓ ' Specify zones where the test will run. Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to 'DEF TIME PARAMs' menu AUTO. DETECTOR TEST (Periodically) ┌────────────────┐ │TIMED FUNCT. T ♦│ │.. │ │. Periodically │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] every │ │ h:mm │ │Change?YES or NO│ └───────┬────────┘ [day ] Monday ... Sunday ┌───────┴────────┐ │TIMED FUNCT. T │ │[day ] every │ │hh:mm │ │ │ └───────┬────────┘ ┌───────┴────────┐ │TIMED FUNCT. T │ │[stat] zone ZZ │ │[status ] │ │Change?YES or NO│ └────────────────┘ [stat ] in NOT in 80 <-- Select 'Periodically' Specify days and period interval for test Press '✓ ' to change the displayed period Press 'X' to retain the displayed period Repeat for all days If change requested: Specify days and times for test Enter 2 digit number (hour). Press '✓ ' Enter 2 digit number (min). Press '✓ ' Specify zones where the test will run. Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to 'DEF TIME PARAMs' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : AUTO. LOG-OFF Define the time after which, if no keys have been used on a keypad, the user is automatically logged-off and any incomplete operation aborted. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. Auto logoff │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMS │ │Auto log off │ │after xxx secs │ │ │ └────────────────┘ <-- Select 'System' <-- Select 'Def Time Param' <-- Select 'Auto logoff' Specify automatic log-off period. Enter 3 digit number (secs). Press '✓ ' Returns to 'DEF TIME PARAMs' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 81 DEFINE : AUTOMATIC SHUNT This facility will present the user with the ‘Clear Alarms’ command following log-on if the users area is in an alarm condition. Three attempts at ‘Clear Alarms’ may then be made, whereupon, if point(s) are still off-normal shunts will be automatically applied. The shunts are conditional, viz. the points are configured as shuntable; the shunt total is within limit; the user has zone access for the applicable zones. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. Auto. Shunt │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │AUTOMATIC SHUNT │ │[status ]│ │Change?YES or NO│ │ │ └────────────────┘ [status ] Enabled Disabld 82 <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'Auto. Shunt' Specify requirement for Automatic Shunt. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status Returns to 'MISC SYS PARAMS' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : AUXILIARY POINT LOGGING Defines the logging of Auxiliary Point activation to be when the system is set, when unset or for when both set and unset. Logging can be further controlled on a per-point basis (see POINT INPUT : ADD). Log entries are limited to once a minute. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. Aux Pt Logging│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │AUX PT LOGGING ♦│ │1 When Set │ │2 When Unset │ │3 Always │ └────────────────┘ <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'Aux Pt Logging' Specify system-wide the behaviour of auxiliary point logging. Returns to the 'MISC SYS PARAMS' menu. Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 83 DEFINE : BANK/COMMERCIAL There are differences in alarm clearing in the bank and commercial sectors. This option allows the system to be tailored for use in these two sectors. If the system is configured as a commercial system, performing the Clear Alarms function also unsets the affected zones. If the system is configured as a bank system, any prewarning conditions will automatically be cleared when the master logs-on, and all clears and mutes apply to the zones to which the user has access irrespective of the keypad access. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Bank/ Commerce│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARAM │ │[premises type ]│ │installation │ │Change YES or NO│ └────────────────┘ [premises type ] Commercial Bank 84 <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Bank/ Commerce' Specify type of installation. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status Returns to 'MISC SYS PARAMS' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : BATTERY TEST ON SET This facility enables a battery test to be performed on each occassion that the system is set. When 'battery test on set' is configured a test will be performed whenever a user performs a set at a keypad. This includes full and partial set, extended and temporary set, but excludes the resecuring of ATM bypass zones. The test will also be performed if a remote set is performed. If the test fails then the user setting or remote setting is prohibited. The test will be performed when an automatic set on schedule expiry occurs. In this case a failed test will not prevent the setting. The process of battery testing causes a delay of approx. 25 seconds. Battery failure is declared when the measured battery voltage is below 11.7V. A remote comms event can be configured to signal battery fail on set. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 3♦│ │.. │ │. Test on set │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TEST ON SET │ │Battery test │ │[status ]│ │Change?YES or NO│ └────────────────┘ [status ] Disabld Enabled <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'More Params' <-- Select 'Test on set' Specify if battery test is performed on setting. Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to the 'MISC SYS PARA 3' menu. Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 85 DEFINE : BELL TEST TIMEOUT Configure time-out for Bell Test. This determines when the Bell Test will terminate if the user fails to manually terminate the test. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. Bell test t/o │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMS │ │Bell tst timeout│ │after xx mins │ │ │ └────────────────┘ 86 <-- Select 'System' <-- Select 'Def Time Param' <-- Select 'Bell test t/o' Specify timeout for bell test. Enter 2 digit number. Press '✓ ' Returns to 'DEF TIME PARAMs' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : DURESS ALARM Duress is the means by which a user can raise an alarm through the keypad when he logs-on. Therefore, if he is forced to provide entry for unauthorized personnel, he can raise an alarm without causing suspicion. The duress type may be configured as shown below. In addition, the user may be required to confirm the duress alarm by pressing '✓ ' to the configured duress confirmation prompt. The meaning of each duress type is described elsewhere and is not given here for security reasons. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Duress Alarm │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DURESS TYPE ♦│ │[type menu ]│ │[type menu ]│ │[type menu ]│ └───────┬────────┘ [type menu ] . Type 1 . Type 2 . Type 3 . Type 4 . not used <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Duress Alarm' Specify duress type Select required option. Press '✓ '. ┌───────┴────────┐ │DURESS TYPE │ │[line 2 ]│ │confirmation │ │Change?YES or NO│ └───────┬────────┘ [line 2 ] NO duress Use duress Only displayed if a duress type is used: Specify whether duress confirmation is required. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status ┌───────┴────────┐ │DURESS CONF TEXT│ │♦ │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │[line 1 ]│ │on zone ZZ │ │zzzzzzzzzzzzzzzz│ │Change?YES or NO│ └────────────────┘ [line 1 ] NOT unset-duress Unset on duress Only displayed if duress confirmation is used: Specify prompt for duress confirmation. Select characters (see USING THE KEYPAD) Only displayed if a duress type is used: Specify whether zone is to be unset on confirmed duress. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status Returns to 'MISC SYS PARAM' menu. Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 87 DEFINE : GROUP SHUNT A Group Shunt allows a group of points to be shunted or unshunted in a single operation. If any of the points in the list fail to shunt/unshunt, then none of the points in the list will be shunted/unshunted. Such failures can be caused if the user has no access to the zone in which a point lies, or if the operation would cause an alarm. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Shunt Lists │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │POINT LIST TYPE♦│ │.. │ │. Group Shunt │ │.. │ └────────────────┘ <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Shunt Lists' <-- Select 'Group shunt' GROUP SHUNT (Add) ┌────────────────┐ │GROUP SHUNT │ │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD GS LIST G │ │Enter Descriptor│ │♦ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD GS LIST G │ │gggggggggggggggg│ │. Add point │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD GS LIST G │ │gggggggggggggggg│ │Enter Point: xxx│ │ │ └───────┬────────┘ <-- Select 'Add' Specify descriptor. Select characters (see USING THE KEYPAD) <-- Select 'Add point' Specify point number. Enter 3 digit number. Press '✓ ' DEFINE : GROUP SHUNT (Add) continued overleaf 88 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : GROUP SHUNT (Add) continued ┌───────┴────────┐ │ADD GS LIST G │ │gggggggggggggggg│ │. Add point │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD GS LIST G │ │gggggggggggggggg│ │. Remove point │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD GS LIST G │ │Remove Point III│ │iiiiiiiiiiiiiiii│ │Delete?YES or NO│ └────────────────┘ ┌───────┴────────┐ │ADD GS LIST G │ │gggggggggggggggg│ │. Quit │ │.. │ └────────────────┘ If Group Shunt to include more than one point: <-- Select 'Add point' Repeat process as above If an added point requires removal: <-- Select 'Remove point' Specify point number(s) Press '✓ ' to delete Press 'X' to retain Press 'C' to quit If all required points added: <-- Select 'Quit' Returns to menu NOTES 'invalid number' Number selected is out-of-range. 'invalid point' The point number selected is not configured or the number has already been selected. GROUP SHUNT (Remove) ┌────────────────┐ ♦│ │GROUP SHUNT │.. │ │. Remove │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE GS LIST G│ │gggggggggggggggg│ │Press YES or NO │ │ │ └────────────────┘ <-- Select 'Remove' Press '✓ ' to remove list Press 'X' to retain list Returns to 'POINT LIST TYPE' menu if successful GROUP SHUNT (Modify) ┌────────────────┐ ♦│ │GROUP SHUNT │.. │ │. Modify │ <-- Select 'Modify' │.. │ └───────┬────────┘ .............continue as for GROUP SHUNT (Add) DEFINE : GROUP SHUNT continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 89 DEFINE : GROUP SHUNT continued GROUP SHUNT (View) ┌────────────────┐ ♦│ │GROUP SHUNT │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT LIST G │ │gggggggggggggggg│ │Pt III in list ♦│ │iiiiiiiiiiiiiiii│ └────────────────┘ 90 <-- Select 'View' Display of points in Group Shunt . Use '▲' or '▼' to scroll point list. Press 'C' to continue Returns to 'GROUP SHUNT' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : HS SHUNT A High Security Shunt allows a group of points to be shunted with the cooperation of two users. The first user must enable the shunt for a number of days. The second user can then turn the shunt on and off until either the first user disables the shunt or the time specified by the first user expires. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MODIFY SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Shunt Lists │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │POINT LIST TYPE♦│ │.. │ │. High Security │ │.. │ └────────────────┘ <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Shunt Lists' <-- Select 'High Security' HS SHUNT (Add) ┌────────────────┐ │HS SHUNT │ │.. │ │. Add │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD HSS LIST H │ │Enter descriptor│ │♦ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD HSS LIST H │ │hhhhhhhhhhhhhhhh│ │. Add point │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD HSS LIST H │ │hhhhhhhhhhhhhhhh│ │Enter Point: xxx│ │ │ └───────┬────────┘ <-- Select 'Add' Specify descriptor. Select characters (see USING THE KEYPAD) <-- Select 'Add point' Specify point number. Enter 3 digit number. Press '✓ ' DEFINE : HS SHUNT (Add) continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 91 DEFINE : HS SHUNT (Add) continued ┌───────┴────────┐ │ADD HSS LIST H │ │hhhhhhhhhhhhhhhh│ │. Add point │ │ │ └───────┬────────┘ ┌───────┴────────┐ │ADD HS SHUNT H │ │hhhhhhhhhhhhhhhh│ │. Remove point │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ADD HS SHUNT H │ │Remove Point III│ │iiiiiiiiiiiiiiii│ │Delete?YES or NO│ └───────┬────────┘ ┌───────┴────────┐ │ADD HSS LIST H │ │hhhhhhhhhhhhhhhh│ │. Quit │ │.. │ └────────────────┘ If HS Shunt to include more than one point: <-- Select 'Add point' Repeat process as above If an added point requires removal: <-- Select 'Remove point' Specify point number(s) Press '✓ ' to delete Press 'X' to retain Press 'C' to quit If all required points added: <-- Select 'Quit' Returns to menu NOTES 'invalid number' Number selected is out-of-range. 'invalid point' The point number selected is not configured or the number has already been selected. HS SHUNT (Remove) ┌────────────────┐ ♦│ │HS SHUNT │.. │ │. Remove Shunt │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE HS SHUNT │ │hhhhhhhhhhhhhhhh│ │Press YES or NO │ │ │ └────────────────┘ <-- Select 'Remove Shunt' Specify shunt number. Press '✓ ' to remove shunt Press 'X' to retain shunt Returns to ‘HS Shunt’ menu if successful HS SHUNT (Modify) ┌────────────────┐ ♦│ │HS SHUNT │.. │ │. Modify │ <-- Select 'Modify' │.. │ └───────┬────────┘ │ ............. continue as for HS SHUNT (Add) DEFINE : HS SHUNT continued overleaf 92 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : HS SHUNT continued HS SHUNT (View) ┌────────────────┐ ♦│ │HS SHUNT │.. │ │. View │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW PT LIST H │ │hhhhhhhhhhhhhhhh│ │Pt III in list │ │iiiiiiiiiiiiiiii│ └────────────────┘ <-- Select 'View' Display of points in HS Shunt. Use '▲' or '▼' to scroll point list. Press 'C' to continue Returns to 'HS SHUNT' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 93 DEFINE : INOVA MPC CARD IDs The INOVA MPC card IDs enable the Windsor 700 to communicate with an INOVA PrintServer. The INOVA PrintServer is supplied with two Master Programming Cards (MPCs), each of which has an embossed 4 digit number. These two numbers are configured on the Windsor 700 using this option. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MODIFY SYSTEM ♦│ │.. │ │. Remote Comms │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOTE COMMS ♦│ │.. │ │. INOVA MPC │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │INOVA MPC │ │Master card-x │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │INOVA MPC n │ │Enter id-0000 │ │ │ │ │ └────────────────┘ 94 <-- Select 'System' <-- Select 'Remote Comms' <-- Select 'INOVA MPC' Specify 1st or 2nd card id to modify. Enter 1 digit number. Press '✓ ' Specify MPC card id. Enter 4 digit number. Press '✓ ' Returns to the 'REMOTE COMMS' menu. Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : INVALID PIN RESPONSE The Invalid PIN Response allows the users to unset a specified zone(s) regardless of schedule restrictions by entering four consecutive invalid PINs. You should further specify which zones can be unset using this method (see ZONES : ADD). ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. Keypad Alarm │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │KEYPAD ALARM │ │Keypad Alarm │ │[status ]│ │Change?YES or NO│ └────────────────┘ [status ] Disabled Enabled <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'Keypad Alarm' Specify if an invalid PIN response should be recognised. Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to the 'MISC SYS PARA 2' menu. Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 95 DEFINE : IP PORTS When the Windsor 700 is to be connected to an IP network the ‘well-known ports’ require specification. Ports are used in the TCP to name the ends of logical connections which carry long term conversations. The ‘well-known port’ is used by the server process as the contact port. The two numbers required, for the ACU (Windsor 700) and the host (ie Guardstation) are configurable using this option. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Remote Comms │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOTE COMMS ♦│ │.. │ │. IP Ports │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │IP PORTS │ │ACU xxxxx │ │ │ │ │ └───────┬────────┘ ┌───────┴────────┐ │IP PORTS │ │Host xxxxx │ │ │ │ │ └────────────────┘ 96 <-- Select 'System' <-- Select 'Remote Comms' <-- Select 'IP Ports' Specify ACU (Windsor 700) Port number. Enter 5 digit number. Press '✓ ' Specify Host Port number. Enter 5 digit number. Press '✓ ' Returns to the 'REMOTE COMMS' menu. Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : LIMIT TIME ADJUST This facility allows the limit on the use of the ‘Time Adjust’ command to be changed from the default which is 1 adjustment every 28 days to a limit of 2 adjustments in 24 hours. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. Limit Time Adj│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │LIMIT TIME ADJ │ │to twice in 24H │ │[status ]│ │Change?YES or NO│ └────────────────┘ [status ] Disabled Enabled <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'Limit Time Adj' Specify restriction on Time Adjust command Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to the 'MISC SYS PARA 2' menu. Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 97 DEFINE : LINE FAULT OVERRIDE This facility configures whether the Line Fault status of the communicator will affect the setting of the system. The effect of Line Fault is stored by this method in the configuration data and will therefore not be lost on power interruption. An alternative method of line fault override which does not affect the configuration is available - see SET:LINE FAULT OVERRIDE. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Line Fault O/R│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARAM │ │Line Fault │ │[status ]│ │Change?YES or NO│ └────────────────┘ [status ] Ignored on Set Prevents Set 98 <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Line Fault O/R' Specify line fault action. Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to the 'MISC SYS PARA 1' menu. Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : LOG-IN METHOD This facility is used to determine the log-in method to be used on the system. When a method is specified as 'required' this means that the method is essential for a user to log-in. For example if the system has 'PIN required' then users must use a PIN, or if the system has 'PIN required' and 'Card required' then users must use a Card and also a PIN in order to log-in. When a card is specified as required but the keypad is not configured to have a card reader then the PIN will be used to log-in at that keypad. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Configuration │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Login Method │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │LOGIN METHOD │ │[PIN status ]│ │Change?YES or NO│ │ │ └───────┬────────┘ [PIN status ] PIN required PIN not required ┌───────┴────────┐ │LOGIN METHOD │ │Electronic Key │ │[El. key status]│ │Change?YES or NO│ └───────┬────────┘ [El. key status ] required not required ┌───────┴────────┐ │LOGIN METHOD │ │Card │ │[Card status ]│ │Change?YES or NO│ └────────────────┘ [Card status ] required not required <-- Select 'Configuration' <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Log-in Method' Select whether PIN entry is required. Press 'X' to retain displayed status Press '✓ ' to change displayed status Select whether Electronic key is required. Press 'X' to retain displayed status Press '✓ ' to change displayed status Select whether Card is required. Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to MISC SYS PARAMS menu if successful Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 99 DEFINE : MANAGED RESET This facility is used in a system where full user reset is disabled. By configuring Managed Reset the user may reset alarms following confirmation from the Central Station. When the user logs on following an alarm the alarm log is presented followed by the 'Managed Reset' display. This presents the user with a contact number for the Central Station and a code number. The user should contact the Central Station and quote the code number. In response the user will be given a 5-digit PIN code and should log-on with this PIN. This will reset the system. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. Managed Reset │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MANAGED RESET │ │[status ]│ │Change?YES or NO│ │ │ └────────────────┘ [status ] Disabled Enabled ┌───────┴────────┐ │MANAGED RESET │ │Contact info. │ │♦ │ │ │ └────────────────┘ <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'Managed Reset' Specify if Managed Reset facility should be available. Press 'X' to retain displayed status Press '✓ ' to change displayed status If Managed Reset facility enabled: Select up to 16 characters (see USING THE KEYPAD). Numbers may be entered directly. Configurable text may be used to store, for example, a telephone number to contact. Returns to 'MISC SYS PARAMS' menu 100 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : NEW PIN LOCKOUT Once a PIN has been changed, it may not be changed again for a period of time known as the new PIN lockout period. This facility is provided to prevent PIN changing being used as a means to discover other PINs. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. New PIN lockou│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMS │ │New PIN change │ │lockout- xx days│ │ │ └────────────────┘ <-- Select 'System' <-- Select 'Def Time Param' <-- Select 'New PIN lockou' Specify the period during which a PIN may not be changed. Enter 2 digit number (days). Press '✓ ' Returns to 'DEF TIME PARAMs' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 101 DEFINE : PIN COMMAND FACILITY The PIN Command facility allows the user to quickly set or unset a specified zone by entering the PIN, followed by the Clear key. They are then prompted for the number of the zone to set/unset. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. PIN commands │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │PIN COMMANDS │ │[line 2 ]│ │Facility │ │Change?YES or NO│ └────────────────┘ [line 2 ] No PIN Command PIN Command 102 <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'PIN commands' Specify if PIN commands are allowed. Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to the 'MISC SYS PARAMS' menu. Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : PIN EXPIRY To reduce the likelyhood of PINs being discovered, each PIN must be changed every so often. This period is known as the PIN expiry time. After a PIN has expired, the user is allowed to log-on one final time. If the warning message is ignored and the PIN not changed, the PIN is deleted and the user is not allowed to log-on again. If this happens the master can allocate a new PIN using the enable user facility. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. PIN expiry tim│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMS │ │PIN must change │ │after-xxxx days │ │ │ └────────────────┘ <-- Select 'System' <-- Select 'Def Time Param' <-- PIN expiry tim' Specify PIN validity period. Enter 4 digit number. Press '✓ ' Returns to 'DEF TIME PARAMs' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 103 DEFINE : PREVENT AUTO SET ALARMS The Prevent Auto Set Alarms facility controls whether an automatic set is performed if this would cause an alarm. This is required in order to satisfy the requirements of BS4737. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. BS4737 Mode │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │BS4737 MODE │ │Auto. Set may │ │cause alarms │ │Change?YES or NO│ └────────────────┘ 104 <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'BS4737 Mode' Specify whether an automatic set is performed if this would cause an alarm. Press 'X' to retain displayed status Press '✓ ' to change displayed status Returns to the 'MISC SYS PARA 2' menu. Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : RESET AUTHORITY In a commercial system connected to a central station, it is usual to require a service visit after an alarm. By disabling full user reset it is possible to prevent the user setting the system until a serviceman has performed a reset. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Rst Authority │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARAM │ │Full user reset │ │[reset status ]│ │Change?YES or NO│ └────────────────┘ [reset status ] Enabled Disabld <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Rst Authority' Specify user reset capability. Press '✓ ' to change specified capability Press 'X' to retain specified capability Returns to 'MISC SYS PARA 1' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 105 DEFINE : SCHEDULE ALARM The schedules not only define when a zone may be opened, but also when it must be set. If a zone is not set by the time the schedule closes, an alarm will be generated if this feature is enabled. ┌────────────────┐ ♦│ │CONFIG MENU │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. Schedule Alarm│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMS │ │Schedule timer │ │[alarm status ]│ │Change?YES or NO│ └────────────────┘ [alarm status ] Disabld Enabled 106 <-- Select 'System' <-- Select 'Def Time Param' <-- Select 'Schedule Alarm' Specify schedule timer. Press '✓ ' to change displayed status Press 'X' to retain displayed status Returns to 'DEF TIME PARAMs' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : TAMPER RESET This facility configures whether users are restricted in that they are not able to reset a system after a tamper. The reset which is restricted is either a manual or an automatic reset function. If the 'Tamper reset' is disabled then the restriction applies. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 3♦│ │.. │ │. Tamper reset │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TAMPER RESET │ │[status ]│ │Change?YES or NO│ │ │ └────────────────┘ [status ] Disabld Enabled <-- Select 'System' <-- Select 'Misc sys Param' <-- Select 'More Params' <-- Select 'More Params' <-- Select 'Tamper reset' Specify tamper reset. Press '✓ ' to change displayed status Press 'X' to retain displayed status Returns to 'MISC SYS PARA 3' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 107 DEFINE : UI LOCKOUT Define the number of consecutive failed PIN entries that are allowed before the keypad is rendered unusable and the period of time that the keypad will remain unusable. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Def Time Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEF TIME PARAMs♦│ │.. │ │. UI lockout tim│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYS TIME PARAMS │ │Max number of │ │failed PINS -x │ │ │ └───────┬────────┘ ┌───────┴────────┐ │SYS TIME PARAMS │ │UI lock out time│ │xxx seconds │ │ │ └────────────────┘ 108 <-- Select 'System' <-- Select 'Def Time Param' <-- Select 'UI lockout tim' Specify the number of failed PINs. Enter 1 digit number. Press '✓ ' Specify the lockout time. Enter 3 digit number (secs). Press '✓ ' Returns to 'DEF TIME PARAMs' menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : VERIFY ALARM Define the verified alarm function. This function will cause a special Verified Alarm event to be reported only when two verifiable alarm states occur within a configured time of each other. This is designed to reduce false alarms. Verified alarms are restricted to Night Alarm points, 24 hour points, Bell tamper and Entry Route Timeout. The configured time between states for a verified event (known as the Verified Alarm Duration) is from 1 to 255 minutes. A duration of zero is used to configure a duration until the system or zone is next unset. When using verified alarms the individual alarm events of the involved points may be suppressed. This applies to the following events: 24H 24Hr Alarm (in any zone) 24H1 - 24H8 24Hr Alarm in Zone Z NA Night Alarm (in any zone) NA1 - NA8 Night Alarm in Zone Z P001 - P250 Alarm on point I The following events are used to report the verified alarm: VAS Verified Alarm (system) VAL1 - VAL8 Verified Alarm in Zone Z The VAS event is caused by two verifiable sensors in any part of the system going into alarm within the Verified Alarm Duration of each other. The VALn event is caused by two verifiable sensors which are both in zone n going into alarm within the Verified Alarm Duration of each other. The Bell tamper is considered to be in all zones. The Clear Alarms command will clear any existing or potential verified alarms. (Note however that if more than one verifiable points remains off-normal when performing Clear Alarms then a verified alarm will be generated because the points are re-asserted). Unsetting the system will clear any existing or potential verified alarms. Note: The Verified Alarm Duration is accurate to the minute. Therefore, for example, a duration of 1 minute will mean a verified alarm may be generated if the interval between verified alarms is 1 min 59 seconds. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 2♦│ │.. │ │. More Params │ │.. │ └───────┬────────┘ <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'More Params' <-- Select 'More Params' DEFINE : VERIFY ALARM continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 109 DEFINE : VERIFY ALARM continued ┌───────┴────────┐ │MISC SYS PARA 3♦│ │.. │ │. Verify Alarm │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VERIFY ALARM │ │Duration │ │xxx minutes │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VERIFY ALARM │ │suppress origin │ │[status ] │ │Change?YES or NO│ └───────┬────────┘ [status ] Disabld Enabled ┌───────┴────────┐ │VERIFY ALARM │ │verify bell │ │tamper [status ]│ │Change?YES or NO│ └────────────────┘ [status ] Disabld Enabled <-- Select 'Verify Alarm' Specify duration. Enter 3 digit number. Press '✓ ' (Duration is in the range 001 to 255, or 000 = Duration is until zone/system is unset) Specify whether the originating alarm events are to be communicated. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status Specify whether bell tamper is to be a verifiable alarm. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status Returns to 'MISC SYS PARA 3' menu 110 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F DEFINE : WORK LATE TYPE Define if Late Working is to be fixed increment or a variable increment. For the fixed increment the extension time is defined. Note: This defines whether the Early Opening type is fixed or variable as well. ┌────────────────┐ │CONFIG MENU ♦│ │.. │ │. System │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SYSTEM ♦│ │.. │ │. Misc Sys Param│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARA 1♦│ │.. │ │. Work Late Type│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │MISC SYS PARAM │ │Fixed increment │ │[work late stat]│ │Change?YES or NO│ └───────┬────────┘ [work late stat ] Work Late USED Work Late UNUSED ┌───────┴────────┐ │MISC SYS PARAM │ │Work Late Delay │ │increment │ │-xxx minutes │ └────────────────┘ <-- Select 'System' <-- Select 'Misc Sys Param' <-- Select 'Work Late Type' Specify whether a fixed or variable increment is to be used for late working. Press '✓ ' to change the displayed status Press 'X' to retain the displayed status If fixed increment used: Specify increment. Enter 3 digit number. Press '✓ ' Returns to 'MISC SYS PARAMS' menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 111 POINT INPUT : ISOLATE/DEISOLATE Isolating a detector causes off-normal and tamper states to be ignored. This is useful when you require a system to set despite point(s) being in tamper or at fault. The point must be configured as isolatable for this procedure and there is a configured limit to the number of isolated or soaked points in a zone. ISOLATE ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Point control │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │POINT CONTROL ♦│ │.. │ │. Isolate point │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ISOLATE POINT │ │Enter point │ │number:- xxx │ │ │ └────────┬───────┘ ┌────────┴───────┐ │ISOLATE PT. III │ │iiiiiiiiiiiiiiii│ │Press YES or NO │ │ │ └────────────────┘ <-- Select 'Point Control' <-- Select 'Isolate point' Specify point number to be isolated. Enter 3 digit number. Press '✓ ' Display of point number for confirmation. Press '✓ ' to isolate Press 'X' to abort Returns to FUNCTION SELECT menu NOTES 'Isolate point' not in menu There are no isolatable points. 'invalid number' The number selected is out-of-range. 'invalid point' The point number selected can not be isolated. 'Pt is isolated' The point selected is already isolated. 'Cannot modify pt' The point is configured to be not isolatable. 'limit exceeded' The zone already has the maximum permitted number of isolated points. 'Pt is in soak' A point which is already in soak test cannot be isolated. POINT INPUT : ISOLATE/DEISOLATE continued overleaf 112 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F POINT INPUT : ISOLATE/DEISOLATE continued DEISOLATE ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Point Control │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │POINT CONTROL ♦│ │.. │ │. Deisolate pt │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │DEISOL. PT. III │ │iiiiiiiiiiiiiiii│ │Press YES or NO │ │ │ └────────────────┘ <-- Select 'Point Control' <-- Select 'Deisolate pt' Display of isolated point(s) Press '✓ ' for deisolate Press 'X' to scroll Returns to 'FUNCTION SELECT' menu NOTES 'Deisolate pt' not in menu ┌────────────────┐ │DEISOL. PT III │ │iiiiiiiiiiiiiiii│ │Press YES or NO │ │[warning message│ └────────────────┘ [warning message ] Alarm cond Windsor 700 Service Manual V8.4 Iss.0F There are no points isolated. Deisolating the point will cause the displayed effect Press '✓ ' to deisolate Press 'X' to scroll Guardall Ltd 113 RESET : NET RESTART This facility restarts the Data Gathering and User Interface Networks. ┌────────────────┐ │RESET AND MUTE ♦│ │.. │ │. Net restart │ │.. │ └────────────────┘ 114 <-- Select 'Net restart' Returns to the 'FUNCTION SELECT' menu. Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F RESET : SERVICE This facility performs the following 1. Remove all shunts and isolates. 2. Clear all latched point inputs and outputs. 3. Restart the Data Gathering network and the User Interface network. On completion the system is left unset. ┌────────────────┐ │RESET AND MUTE ♦│ │.. │ │. Service Reset │ │.. │ └────────────────┘ <-- Select 'Service Reset' Returns to the 'FUNCTION SELECT' menu. NOTES ┌────────────────┐ │RESET FAILED │ │SYSTEM STILL │ │IN ALARM │ │Press CLEAR │ └────────────────┘ Windsor 700 Service Manual V8.4 Iss.0F Check the system status to see what is still in alarm. Guardall Ltd 115 SERVICEMAN : COMMISSION REMOTE COMMS Windsor 700 is able to talk to the GuardStation remote controller. This allows a central user to monitor and manage many systems. Windsor 700 can also be configured to report alarms to the GuardStation. Having configured the system and set up GuardStation, the remote link must be commissioned. This allows the GuardStation to pass essential information to the Windsor 700 which will be required for future conversations. Having commissioned remote communications, the information passed to the Windsor 700 is stored in the same memory as the configuration. The act of decommissioning deletes this information. There are several reasons for wanting to do this: (i) the GuardStation is being taken out of service and the Windsor 700 must no longer communicate with it; (ii) the network address or telephone number of the GuardStation has changed so the remote communiations must be recommissioned; (iii) the GuardStation has been replaced by another without copying the database from the old to the new; (iv) the configuration has been copied from another Windsor 700, in this case all sites must be decommissioned before any is recommisioned — failure to do this will result in the Windsor 700s having the same identity; and (v) remote communications was configured with encryption disabled but encryption is now required - the encryption keys form part of the information passed during commisioning. Note that decommissioning does not communicate with the GuardStation, therefore a similar procedure (called "deinitialising" must be carried out there. Note also that encryption for a given site may be enabled or disabled using the Remote Comms option Encryption. COMMISSION REMOTE COMMS ┌────────────────┐ │FUNCTION SELECT♦│ │. .. │ │. PIN/User menu │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │PIN/ USER MENU ♦│ │. .. │ │. Commission RC │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │COMMISSION RC │ │Site selected │ │rrrrrrrrrrrrrrrr│ │Press YES or NO │ └───────┬────────┘ ┌───────┴────────┐ │Please telephone│ │pppppppppppppppp│ │nnnnnnnnnnnnnnnn│ │YES when ready │ └───────┬────────┘ <-- Select 'PIN/User menu' <-- Select 'Commission RC' The Remote Site(s) configured are displayed. Use '▲' or '▼' to scroll the required site to line 3. Press '✓ ' Contact the Remote Site operator in order to establish that you require the commissioning. When the Remote Site operator is ready: Press '✓ ' before the remote site operator initiates the process. SERVICEMAN : COMMISSION REMOTE COMMS continued overleaf 116 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F SERVICEMAN : COMMISSION REMOTE COMMS continued ┌───────┴────────┐ │COMMISSION RC │ │Please wait for │ │rrrrrrrrrrrrrrrr│ │to commission │ └───────┬────────┘ The system is ready for commissioning. During commissioning this will be displayed. Press 'C' if abort required The commission will also be aborted if the serviceman is automatically logged-off. If the panel cover has not been removed, press a numeric key occasionally to avoid being logged-off. ┌───────┴────────┐ │COMMISSION RC │ │rrrrrrrrrrrrrrrr│ │SUCCESS │ │Press CLEAR │ └────────────────┘ The commissioning has been successful Press 'C' to return to menu NOTES ┌────────────────┐ │There are no │ │uncommissioned │ │sites available │ │Press CLEAR │ └────────────────┘ ┌────────────────┐ │COMMISSION RC │ │rrrrrrrrrrrrrrrr│ │FAILED │ │Press CLEAR │ └────────────────┘ There are no Remote Sites configured or all the Remote Sites configured have already been commissioned. Press 'C' to return to menu 'C' was pressed to abort commissioning. Press 'C' to return to menu DECOMMISSION REMOTE COMMS ┌────────────────┐ │FUNCTION SELECT♦│ │. .. │ │. PIN/User menu │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │PIN/ USER MENU ♦│ │. .. │ │. Decommission │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │DECOMMISSION │ │Site selected │ │rrrrrrrrrrrrrrrr│ │Press YES or NO │ └────────────────┘ <-- Select 'PIN/User menu' <-- Select 'Decommission' The Remote Site(s) commissioned are displayed. Use '▲' or '▼' to scroll the required site to line 3. Press '✓ ' SERVICEMAN : COMMISSION REMOTE COMMS continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 117 SERVICEMAN : COMMISSION REMOTE COMMS continued NOTES ┌────────────────┐ │Remote │ │communications │ │not commissioned│ │Press CLEAR │ └────────────────┘ 118 There are no Remote Sites commissioned Press 'C' to return to menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F SERVICEMAN : LOG-ON To log-on as a serviceman your access must first be established by a user log-on. This will be a customer's representative with an authority level of Master, Manager or User 1. During initial commissioning, or when a system fault has ocurred, there are no user PINs defined. To allow access a default user PIN (1111) is enabled. Use the default user PIN to log-on, select the 'Enable Service' option as shown below and then use the default service PIN (974072) to gain access in the service role. NOTE: The service PIN changes with the date. The default service Pin is based on the default date. Therefore setting the date to the current date will disable the default service PIN. After a configuration has been downloaded from the PROM Pack the default service PIN will change in accordance with the configuration details. The service PIN of the day is normally supplied by the Central Station. This follows USER log-on: ┌────────────────┐ │FUNCTION SELECT♦│ │. .. │ │. PIN/User menu │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │PIN/ USER MENU ♦│ │. .. │ │. Enable service│ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │ENTER SERVICE │ │AUTHORISING CODE│ │:│ │ │ └────────────────┘ <-- Select 'PIN Codes' <-- Select 'Enable service' Select your PIN number then press '✓ ' (For security each digit will appear as an asterisk) Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 119 SERVICEMAN : PANEL ACCESS If the user who is logged-on does not press any key for a configured time (see CONFIGURE : AUTO. LOG-OFF), that user is logged-off. The serviceman may gain extra time by selecting panel access, this increases the log-off period by a configured multiple. If even more time is needed, the panel cover can be removed. Provided the serviceman is logged-on when the cover is removed, no tamper will occur. Once the cover is removed the seviceman will not be automatically logged-off until it is replaced. ┌────────────────┐ │FUNCTION SELECT♦│ │. .. │ │. PIN/User menu │ │. .. │ └───────┬────────┘ ┌───────┴────────┐ │PIN/ USER MENU ♦│ │. .. │ │. Panel access │ │. .. │ └────────────────┘ 120 <-- Select 'PIN/User menu' <-- Select 'Panel access' Remains at the 'PIN/ USER menu' Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F SERVICEMAN : REMOTE COMMS (ENCRYPTION) This facility configures the system whether to encrypt the data communication with a Remote Site. The encryption keys are supplied at the time of commissioning but whether the encryption is used or not depends on the configuration. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. PIN/User menu │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │PIN/ USER MENU ♦│ │.. │ │. Comms encrypt │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOTE SITE │ │rrrrrrrrrrrrrrrr│ │Encrypt [status]│ │Change?YES or NO│ └────────────────┘ [status ] disabled enabled <-- Select 'PIN/User menu' <-- Select 'Comms encrypt' Select whether encrption is applicable. Use '▲' or '▼' to scroll required Remote Site to line 2. Press '✓ ' to change displayed encryption status Press 'X' to retain displayed encryption status Press 'C' to return to PIN/USER menu. Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 121 SERVICEMAN : REMOTE CONFIGURATION A GuardStation may be used to modify the Windsor 700 configuration. The existing configuration indicates which GuardStations (if any) may do this. Remote configuration may be permitted, not permitted, or permitted with local permission. If this last option is used, the serviceman must grant permission using the procedure described here. Once the procedure is complete the serviceman is logged-off. The GuardStation then has 30 minutes in which to commence the download. Permission is rescinded following the download or after a service reset. The GuardStation will be unable to perform a download if any local user is logged-on or if any zone is set. Note that the GuardStation may upload the configuration without local permission. Configuration download Act of sending a new configuration to the Windsor 700. Configuration upload Act of reading the configuration from the Windsor 700, possibly for modification and future download. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. PIN/User menu │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │PIN/ USER MENU ♦│ │.. │ │. Remote Config │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SUPERVISE CONFIG│ │Start download │ │within 30 min │ │Press Clear │ └────────────────┘ 122 <-- Select 'PIN/User menu' <-- Select 'Remote Config' The download period is ready to start. Press 'C' to grant permission and start the timeout. If abort is required perform a 'Service Reset' Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F SET : FORCE This facility allows setting when points are off-normal or a system defect is present by presenting the off-normal points to be shunted; the shunt limits still apply. ┌────────────────┐ │ SET FAILED │ │.. │ │. Force set │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │FORCE SET SHUNT │ │Press YES or NO │ │III iiiiiiiiiiii│ │off-normal │ └───────┬────────┘ ┌───────┴────────┐ │FORCE SET ALLOW │ │Press YES or NO │ │[defect ]│ │ │ └────────────────┘ [defect ] Battery Low Follows failure of conventional set operation: <-- Select 'Force set' If points off-normal: Press '✓ ' to shunt point If system defect: Press '✓ ' to override The set operation is re-tried automatically NOTES ┌────────────────┐ │CALL SECURITY │ │Shunt limit │ │exceeded │ │ │ └────────────────┘ The point is configured as non-shuntable or the total shunt limit is exceeded. Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 123 SET : LINE FAULT OVERRIDE This facility configures the Line Fault Override status of the system. When Line Fault Override is in operation then a user may set the system irrespective of the Line Fault status of the communicator. The Line Fault Override status established by the method below is not retained in the non-volatile configuration memory and will therefore be lost if the Control Unit is de-powered. Also the existing Line Fault Override will be cleared if a configuration is entered. If it is required to place the Line Fault Override status in the non-volatile configuration memory see DEFINE : LINE FAULT OVERRIDE. LINE FAULT OVERRIDE (Enable) ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Set Options │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SET MENU ♦│ │.. │ │. LF override │ │.. │ └────────────────┘ <-- Select 'Set Options' <-- Select 'LF override' Returns to 'SET' MENU NOTES 'LF override' not in menu Line Fault Override is already configured LINE FAULT OVERRIDE (Disable) ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Set Options │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SET MENU ♦│ │.. │ │. Clear LF O/R │ │.. │ └────────────────┘ <-- Select 'Set Options' <-- Select 'Clear LF O/R' Returns to 'SET' MENU NOTES 'Clear LF O/R' not in menu 124 Line Fault Override is not configured Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F STATUS : DIAGNOSTIC LOG Display the Diagnostic Log. This is intended for diagnostic purposes by Guardall. No explanation of this log is given in this manual. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. View Status │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW STATUS ♦│ │.. │ │. Historic log │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │HISTORIC LOG ♦│ │.. │ │. Diagnostic log│ │.. │ └────────────────┘ <-- Select 'View Status' <-- Select 'Historic log' <-- Select 'Diagnostic log' Press 'C' to return to menu Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 125 STATUS : ISOLATE LIST Display list of isolated points (see POINT INPUT : ISOLATE/DEISOLATE in this document, and POINT INPUT : SHUNT/UNSHUNT in the User Manual). ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. View status │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW STATUS ♦│ │.. │ │. Shunt/Isolates│ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SHUNT/ISOLATES ♦│ │.. │ │. Isolate list │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │ISOLATE LIST │ │Pt III isolated │ │iiiiiiiiiiiiiiii│ │ │ └────────────────┘ <-- Select 'View status' <-- Select 'Shunt/Isolates' <-- Select 'Isolate list' Display of isolate list. Use '▲' or '▼' to scroll Press 'C' to return to menu NOTES 'Shunt/Isolates' not in menu 126 No isolatable points Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F STATUS : POINT INPUT (CALIBRATE) This facility displays the current state of a point input and allows the point to be calibrated. The point input circuitry in a concentrator and the connected detector form a resistor network. The state of the point input depends upon the voltage across this network. The point status facility displays the deviation of the present voltage from normal. Typical deviations for each of the three basic concentrators are:No End-of-Line: End-of-Line: High-Security: Normal = 0%, Alarm = -32%, Tamper(device) = +22% Normal = 0%, Alarm = -19%, Tamper(device) = -38% Normal = 0%, Alarm = -22%, Tamper(device) = -44% If the status display is showing a small deviation when the point input is normal, it is possible to recalibrate the point. This may be required if contacts are dirty, the circuit wiring has a small resistance, or to accommodate end-of-line resistor tolerances. Calibration is particularly important for the High-Security Concentrator where the state thresholds are close together. Calibration is not allowed if the present voltage deviates from the nominal normal voltage by more than 6% (the point status is not-normal or marginal), this prevents faulty equipment being calibrated to appear normal. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. View status │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW STATUS ♦│ │.. │ │. Point status │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │POINT xxx STATUS│ │iiiiiiiiiiiiiiii│ │[point status ]│ │Calibrate OK? │ └────────────────┘ [point status ] normal nn% off-normal nn% tamper nn% <-- Select 'View status' <-- Select 'Point status' Press '✓ ' to view next point Use '▲' or '▼' to scroll Press 'X' if the calibration is NOT correct Enter a three digit number and press '✓ ' to view any point. NOTES ┌────────────────┐ │POINT STATUS │ │ Calib error │ │[error status] │ │ │ └────────────────┘ [error status ] Point NOT NORMAL Point MARGINAL Windsor 700 Service Manual V8.4 Iss.0F Calibration is not possible if the point is not normal, or if the point is marginal (close to the thresholds) Guardall Ltd 127 STATUS : PRINT CONFIGURATION This facility prints the configuration data of the Windsor 700 system. The printout is in a compact format employing abbreviations to describe various functions. The abbreviations are in most cases self-explanatory. The meaning of some of the abbreviations is given opposite. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. View status │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │VIEW STATUS ♦│ │.. │ │. Historic log │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │HISTORIC LOG ♦│ │.. │ │. Print config. │ │.. │ └────────────────┘ <-- Select 'View status' <-- Select 'Historic log' <-- Select 'Print config' PRINT CONFIGURATION (Start) ┌────────────────┐ │PRINT CONFIG. ♦│ │.. │ │. Start printout│ │.. │ └────────────────┘ <-- Select 'Start printout' The configuration printout will commence. PRINT CONFIGURATION (Stop) ┌────────────────┐ │PRINT CONFIG. ♦│ │.. │ │. Stop printout │ │.. │ └────────────────┘ 128 <-- Select 'Stop printout' The configuration printout will halt. Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F PRINT CONFIGURATION ABBREVIATIONS FORM A - POINT INPUTS FLAGS S I E L V A Shuntable Isolatable Exemptable Log Signal Point Activations Verifiable Auto-shuntable ATTRIBUTE BUF Buffer point DBF Double Buffer point SSM Safe Shunt Master SSS Safe Shunt Slave BGP Break Glass Point/Call Point LOGICAL FUNCTION ANDO Outputs anded ANDI Inputs anded ORO Outputs ored ORI Inputs ored FORM B - ZONES TYPE NORM ATM Normal zone ATM zone FLAGS ST TA AS EU AU MS RU MC AT SU 2U SE RC Zone is set Timer Alarm on schedule expiry Auto. set on schedule expiry Emergency Unset applicable Auto. unset on schedule open window Monitor shunt facility Restricted unset during schedule open window Manaul operation plus automatic set/unset ATM Control zone Shown on set/unset menu Dual PIN access Secure zone Restricted Command access FORM E - ENTRY/EXIT ROUTES ATTRIBUTES ENT Entry point EXT Exit point IN Entry route point OUT Exit route point IBF Entry route buffer point OBF Exit route buffer point FORM F - KEYPADS TYPE UIC MIM PNT Normal Mimic Printer Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 129 PRINT CONFIGURATION ABBREVIATIONS (continued) FLAGS KSW ENS DSU ATM HNG DAT EKY CHK LOB CRD SUN Keyswitch Enabled when controllable zones set Disabled if controllable zone(s) unset Removable Card reader attached for ATM lobby access Card reader attached for login Display set/unset menu FORM G - CONCENTRATORS TYPE CDN EOL HSC MON NEOL Canadian End-of-line High-security Monarch No end-of-line FORM H - POINT OUTPUTS CONTROL FLAGS MOM Momentary LTH Latched NOF Mormally off TRG Triggered PNT Point gated ? AND Point inputs anded ? CNT Linked point input to be counted ? ? ? ? ATM ATM zone bypassed WTS Walk test DTS Detector test PTS PA test SET Set zones UNS Unset zones EXT Exiting zones ENT Entering zones CMP Compromised zones PWD Prewarning SND Sounders STB Strobes ALM Alarms PAA PA alarms TAM Tampers ARM Armed zones SDC Schedule closing LNF Line Fault MNF Mains Fail ADF Auto Detector test fail ZIS Zone is settable 130 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F TEST : MONITOR The monitor test when started records henceforth any changes of state that the detector makes. The changes may then be reviewed by using the view facility in the test. Monitor test does not affect the operation of the detector in the alarm system. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Test │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TEST MENU ♦│ │.. │ │. Other tests │ │.. │ └────────────────┘ <-- Select 'Test' <-- Select 'Other tests' MONITOR (Start) ┌────────────────┐ │POINT MON. TEST♦│ │.. │ │. Start test │ │.. │ └────────────────┘ <-- Select 'Start test' The detector states will now be recorded. The test may be run for as long as required. Returns to POINT MON. TEST full menu MONITOR (View) ┌────────────────┐ │POINT MON. TEST♦│ │.. │ │. View test │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │POINT MON. TEST │ │Select point for│ │view:- xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │VIEW POINT III │ │iiiiiiiiiiiiiiii│ │[point status ]│ │[test log ]│ └────────────────┘ [point status ] point normal point off-normal point in tamper <-- Select 'View test' Specify detector point number. Enter 3 digit number. Press '✓ ' Display of detector status Use '▲' or '▼' to scroll list Press 'C' to return to menu [test log ] no changes was normal was off-normal was in tamper all states used TEST : MONITOR continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 131 TEST : MONITOR continued NOTES 'invalid number' The number selected is out-of-range. 'invalid point' The number selected is not configured or the point may not be placed in monitor. MONITOR (Stop) ┌────────────────┐ │POINT MON. TEST♦│ │.. │ │. Stop test │ │.. │ └────────────────┘ 132 <-- Select 'Stop test' Returns to POINT MON. TEST menu Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F TEST : SOAK The soak test facility is used to assess the performance of detectors following repair or installation. A detector under soak test does not participate in the alarm system so off-normal and tamper conditions do not generate alarms. However, in order to provide diagnostic information every change of state is entered in the historic log. The log entries are: Point going normal : status = 0 Point going off-normal : status = 1 Point going into tamper : status = 3 There is a configured limit to the number of isolated or soaked points in a zone. The soak test may be started at any time in an unset zone. A detector cannot be removed from soak if so doing would cause an alarm. ┌────────────────┐ │FUNCTION SELECT♦│ │.. │ │. Test │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │TEST MENU ♦│ │.. │ │. Soak test │ │.. │ └────────────────┘ <-- Select 'Test' <-- Select 'Soak test' SOAK (Start) ┌────────────────┐ │SOAK TEST │ │.. │ │. Soak point │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │SOAK POINT │ │Enter point │ │number:- xxx │ │ │ └───────┬────────┘ ┌───────┴────────┐ │SOAK PT. III │ │iiiiiiiiiiiiiiii│ │Press YES or NO │ │ │ └────────────────┘ <-- Select 'Soak point' Specify detector point number required. Enter 3 digit number. Press '✓ ' Confirm selection. Press '✓ ' to continue Press 'C' to abort Press 'X' to select a different point Returns to FUNCTION SELECT menu if successful NOTES 'invalid number' The number is out-of-range. 'invalid point' The point number is not configured or the point may not be placed in soak test. 'Pt is in soak' The selected point is already in soak test. 'limit exceeded' The zone isolate limit is exceeded. TEST : SOAK continued overleaf Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 133 TEST : SOAK continued SOAK (End) ┌────────────────┐ │SOAK TEST │ │.. │ │. Remove point │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │REMOVE PT. III │ │iiiiiiiiiiiiiiii│ │Press YES or NO │ │ │ └────────────────┘ <-- Select 'Remove point' Display of point(s) in soak. Press '✓ ' to remove soak Press 'X' to retain soak Press 'C' to return to menu Returns to SOAK TEST menu automatically if all soak points are removed. NOTES ┌────────────────┐ │REMOVE SOAK │ │ │ │** NO POINTS ** │ │ AVAILABLE │ └────────────────┘ 134 There are no points in soak test. Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F TEST : UI This facility allows the UI to be tested while the system is operational. While in this mode the viewing angle of the LCD may be adjusted for optimum display clarity. For this, the keypad must be removed from the case base. Note that this will not cause a tamper - this is inhibited while the keypad is in self-test. After detaching the keypad from its base locate the potentiometer VR1. Use a small screwdriver to adjust VR1. The extremes of the display are a blank display and a display comprising black rectangles (the background). The optimum position of VR1 will give a display in which the displayed characters are clearly visible and the rectangles of the background have virtually disappeared. When carrying out the adjustment hold the keypad in a position as near as possible to its normal operating position to ensure that the ambient lighting conditions and viewing angle are realistic. ┌────────────────┐ │.. │ │.. │ │.. │ │.. │ └───────┬────────┘ ┌───────┴────────┐ │▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ └───────┬────────┘ ┌───────┴────────┐ │▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ │▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒▒│ └───────┬────────┘ ┌───────┴────────┐ │0000000000000000│ │ │ │UI VERSION Vx.xx│ │ │ └───────┬────────┘ ┌───────┴────────┐ │0000000000000000│ │ │ │UI VERSION Vx.xx│ │ │ └────────────────┘ <-- Press '2' '5' '8' '0' simultaneously Check display For 5 secs: Display of pixel pattern 1 For 2 secs: Buzzer sounds & all LEDs light Check display For 5 secs: Display of pixel pattern 2 Test keypad Key-press should change 0 to 1 corresponding to the order 123456789▲0 X▼C✓ T (T = tamper). Pressing '0' should also light all LEDs and buzzer sounds for 2 secs. <-- Press '2' '5' '8' '0' simultaneously Returns to operational mode Windsor 700 Service Manual V8.4 Iss.0F Guardall Ltd 135 NOTES 136 Guardall Ltd Windsor 700 Service Manual V8.4 Iss.0F