Helium If Andersen-Ziegler stopping is selected then for incident 3 He and 4 He ions the electronic stopping power data by Ziegler [2] are used for all elements. The electronic stopping power Se in eV/(1015 atoms/cm2 ) for incident 4 He ions with energy E in keV is given by 1 1 1 = + Se SLow SHigh (4.27) SLow = A1 E A2 (4.28) with and SHigh A3 A4 = ln 1 + + A5 E E E (4.29) A1 −A5 are fitting coefficients and tabulated in [2]. They are stored in the file STOPHE.DAT. Equations 4.27–4.29 are valid for 1 keV ≤ E < 10 MeV. 4 He-stopping at higher energies (above 10 MeV) is not implemented in the program. The stopping power of 3 He is identical to the stopping power of 4 He at the same velocity [2]. The stopping power of 3 He with energy E is obtained by taking the stopping power value at the energy E(4 He) = 4/3 E(3 He). The stopping power for 3 He is valid in the energy range 10 keV ≤ E < 7.5 MeV. Nuclear stopping for incident helium ions is calculated with the Krypton-Carbon (KrC) potential [26]. The nuclear stopping Sn in eV/1015 atoms/cm2 for He-ions with incident energy E (in keV) is given by: 8.462 Z1 Z2 M1 Sn = sn 2/3 (M1 + M2 ) Z1 2/3 1/2 (4.30) + Z2 sn is the reduced nuclear stopping and Z1 , M1 are the nuclear charge and mass of the helium ion and Z2 , M2 are the nuclear charge and mass of the target element. The reduced nuclear stopping sn has the simple form sn = 0.5 ln(1 + ) + 0.10718 0.37544 (4.31) is the reduced energy and is given by = 32.53 M2 E Z1 Z2 (M1 + M2 ) 2/3 Z1 + 2/3 1/2 Z2 (4.32) Nuclear stopping is only important at incident energies E < 100 keV, at higher energies nuclear stopping becomes negligible. 62