Download hydraulic.
Transcript
Installing the 1756-HYD02 Module Assembling The Removable Terminal Block and the Housing 2-11 Removable housing covers the wired RTB to protect wiring connections when the RTB is seated on the module. 1. Align the grooves at the bottom of each side of the housing with the side edges of the RTB. Figure 2.14 Housing Groove Side edge of RTB Groove Strain relief area Side edge of RTB RTB 20858-M 2. Slide the RTB into the housing until it snaps into place. IMPORTANT If additional wire routing space is required for your application, use extended-depth housing 1756-TBE. Publication 1756-UM525A-EN-P - June 2003