Download LONG RANGE CCD BAR CODE SCANNER USER'S MANUAL
Transcript
LONG RANGE CCD BAR CODE SCANNER USER’S MANUAL Contents 1. Introduction ...........................................................................................- 3 1.1 Installation .......................................................................................... - 3 • Unpacking .............................................................................................. - 3 • Connecting the scanner........................................................................ - 3 1.2 Default Setting .................................................................................... - 5 2. Setting Procedure .................................................................................- 6 2.1 Common setting ................................................................................. - 6 2.2 Parameter setting ............................................................................... - 7 2.3 Interface Selection ............................................................................. - 9 • Keyboard wedge.................................................................................. - 10 • RS232.................................................................................................... - 12 2.4 System setting.................................................................................. - 14 • Scan ...................................................................................................... - 14 • Indication.............................................................................................. - 16 3. Code Option.........................................................................................- 18 • Code 39................................................................................................. - 18 • Code 93................................................................................................. - 20 • Interleaved 2 of 5 ................................................................................. - 22 • Industrial 2 of 5 .................................................................................... - 24 • Standard 2 of 5..................................................................................... - 25 • Code 128............................................................................................... - 27 • CODABAR ............................................................................................ - 29 • EAN 8 .................................................................................................... - 31 • EAN13 ................................................................................................... - 33 • UPCA .................................................................................................... - 35 • UPCE..................................................................................................... - 37 • MSI ........................................................................................................ - 39 • PLESSEY .............................................................................................. - 41 • China post ............................................................................................ - 43 • Italian Pharmacode ( CODE 32 ) ......................................................... - 44 • Matrix 2 of 5.......................................................................................... - 45 • Telepen ................................................................................................. - 47 • CODE11 ................................................................................................ - 49 4. String setting / Transmission .............................................................- 51 • Prefix/Suffix.......................................................................................... - 51 • Preamble / Postamble ......................................................................... - 52 • Insert Group Character ....................................................................... - 53 • Others ................................................................................................... - 54 5. Scanner configuration / Reset to default settings............................- 56 Parameter list ..........................................................................................- 57 - -2- 1. Introduction Thank you very much for purchasing TSC bar code scanner. This decoder is a Long Range (Gun Type) CCD Bar Code Scanner. It works with variety of bar code types, reading devices and computer interface. This manual provides an easy way to setting the decoder by scanning bar codes listed on the menu. Specifications, accessories, parts and programs are subject to change without notice. 1.1 Installation • Unpacking Unpacking the box, the following items are included in the carton. * One scanner unit * One quick start guide If any parts are missing, please contact the Customer Service Department of your purchased reseller or distributor. • Connecting the scanner * USB interface 1. Turn off the power of terminal/computer. 2. Connect the USB cable to the scanner and the terminal/computer. 3. Turn the terminal/computer power on. 4. The scanner will beep a tone after connected. 5. Scan any bar code to ensure the scanner was completed setting. * Keyboard wedge interface (Option) 1. Turn off the power of terminal/computer. 2. Connect the appropriate interface cable to the scanner, the -3- terminal/computer and keyboard. 3. Turn the terminal/computer power on. 4. The scanner will beep a tone after connected. 5. Set the scanner to keyboard wedge setting. (Please refer to section 2.1) 6. Scan any bar code to ensure the scanner completed setting. * RS-232 interface (Option) 1. Turn off the power of terminal/computer. 2. Connect the RS-232 cable to the scanner and the terminal/computer. 3. Turn the terminal/computer power on. 4. The scanner will beep a tone after connected. 5. Set the scanner to RS-232 setting. (Please refer to section 2.1) 6. Scan any bar code to ensure for completed setting. -4- 1.2 Default Setting Code Type Enable Code 39 Code 93 Interleaved 2 of 5 Industrial 2 of 5 Standard 2 of 5 Code 128 Codabar EAN 8 EAN 13 UPC A UPC E MSI Plessey China Post Italian Pharmacode (Code 32) Matrix 2 of 5 Telepen Code 11 X Proprietary ID 1 2 3 4 5 6 7 8 9 A B C D E X X X X X X X -5- AIM Code ID ]A ]G ]I ]S ]R ]C ]F ]E ]E ]E ]E ]M ]P ]X F ]G G H I ]S ]B ]H 2. Setting Procedure 2.1 Common setting Please follow below steps to set your scanner. 1. Scan the bar code from “Enter setting mode” side to start the setting procedure. 2. Select the bar code from “Function” side to enter the option mode. 3. Scan the bar code from “Option” side to set the option function. 4. Scan the bar code from “Exit setting mode” side when finished the setting. Enter setting mode 1 *% $$PRO* Function Interface selection 2 Option Remark Default Auto detection 3 Keyboard wedge *% S1A* RS232 USB Exit setting mode 4 *$$% * -6- 2.2 Parameter setting Please follow below steps to set parameter setting. 1. Scan the bar code from “Enter setting mode” side to start the setting procedure. 2. Select and scan the bar code from “Function” side to enter the option mode. 3. Scan the bar code from the parameter list that listed on back page of the manual to set the parameter. 4. Scan the bar code from “Exit setting mode” when finished the setting. Enter setting mode 1 *% $$PRO* Function Stand-by duration Option 1~99 sec Remark 6 (Default) *% SAB* Double read timeout 2 1~99 (10 ms) 50 (Default) 0~9 times 0 (Default) 0~64 4 (Default) 0~64 63 (Default) *% SAC* Double confirm *% SAD* Global Min. code length *% SAE* Global Max. code length *% SAF* Exit setting mode 4 *$$% * -7- Parameter list (Listed on back page of the manual) Parameter Bar code 0 */0* 1 */1* 2 */2* 3 */3* 4 */4* 5 */5* 6 */6* 7 */7* 8 */8* 9 */9* A */A* B */B* C */C* D */D* E */E* F */F* -8- 3 2.3 Interface Selection Enter setting mode *% $$PRO* Function Interface selection Option Auto detection Keyboard wedge *% S1A* RS232 USB Exit setting mode *$$% * -9- Remark Default • Keyboard wedge Enter setting mode *% $$PRO* Function Keyboard type Option IBM AT, PS/2 Remark Default *% S2A* Reserved Keyboard layout US international Spanish French German Italian *% S2B* Danish Portuguese Swedish Switzerland UK - 10 - Default Latin American Japanese Hungarian Reserved Reserved Keyboard speed 0~8 (0: High speed; 8: Low speed) 3 (Default) *% S2C* Caps lock Caps lock “OFF” Default *% S2D* Caps lock “ON” Power-on simulation Disable Default *% S2E* Enable Inter-character delay 0~99 (ms) 2 (Default) 0~99 (ms) 10 (Default) *% S2F* Block transmission delay *% S2G* Exit setting mode *$$% * - 11 - • RS232 Enter setting mode *% $$PRO* Function Flow control (Handshaking) Option None Remark Default RTS/CTS *% S3A* Xon/Xoff ACK/NAK Baud rate 1200 bps 2400 bps 4800 bps *% S3B* 9600 bps 19200 bps 38400 bps - 12 - Default 57600 bps 115200 bps Parity None Default Odd *% S3C* Even Data bit 8 bits Default *% S3D* 7 bits Stop bit 1 bit *% S3E* 2 bits Exit setting mode *$$% * - 13 - Default 2.4 System setting • Scan Enter setting mode *% $$PRO* Function Scanning mode Option Remark Good-read off Momentary *% SAA* Default Alternate Continue Timeout off Stand-by duration 1~99 second(s) 6 (Default) 1~99 (10 ms) 50 (Default) 0~9 times 0 (Default) 0~64 4 (Default) *% SAB* Double read timeout *% SAC* Double confirm *% SAD* Global Min. code length *% SAE* - 14 - Global Max. code length 0~64 63 (Default) *% SAF* Inverted image scan Disable Default *% SAG* Enable Position indication Disable 30 seconds 60 seconds 90 seconds *% SAH* 120 seconds 150 seconds 180 seconds Enable Exit setting mode *$$% * - 15 - Default • Indication Enter setting mode *% $$PRO* Function Power on alert Option Remark Disable *% SBA* Enable Default LED indication Disable *% SBB* Enable Default Beeper indication Disable *% SBC* Enable Default Beep loudness 0~7 7 (Default) 0~99(100 Hz) 26 (Default) 0~99(ms) 10 (Default) *% SBD* Beep tone frequency *% SBE* Beep tone duration *% SBF* - 16 - Exit setting mode *$$% * - 17 - 3. Code Option • Code 39 Enter setting mode *% $$PRO* Function Option Remark Read Disable *% B1A* Enable Check-sum verification Disable Default Default *% B1B* Enable Check-sum transmission Disable Default *% B1C* Enable Code ID setting Hex 00-FF ASCII 1 (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) *% B1D* Max. code length *% B1E* Min. code length *% B1F* Truncate leading *% B1G* - 18 - Truncate ending 0-15 0 (Default) *% B1H* Start/End transmission Disable Default *% B1J* Enable Insert group number 00-44 00 (Default) *% B1M* Format ( Standard Full ASCII ) Disable *% B1R* Enable Exit setting mode *$$% * - 19 - Default • Code 93 Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% B2A* Enable Check-sum verification Disable *% B2B* Enable Check-sum transmission Disable Default Default *% B2C* Enable Code ID setting Hex 00-FF ASCII 2 (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) 0-15 0 (Default) 00-44 00 (Default) *% B2D* Max. code length *% B2E* Min. code length *% B2F* Truncate leading *% B2G* Truncate ending *% B2H* Insert group number *% B2M* - 20 - Exit setting mode *$$% * - 21 - • Interleaved 2 of 5 Enter setting mode *% $$PRO* Function Option Remark Read Disable *% B3A* Enable Check-sum verification Disable Default Default *% B3B* Enable Check-sum transmission Disable Default *% B3C* Enable Code ID setting Hex 00-FF ASCII 3 (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) 0-15 0 (Default) *% B3D* Max. code length *% B3E* Min. code length *% B3F* Truncate leading *% B3G* Truncate ending *% B3H* - 22 - Insert group number 00-44 *% B3M* Exit setting mode *$$% * - 23 - 00 (Default) • Industrial 2 of 5 Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% B4A* Enable Code ID setting Hex 00-FF ASCII 4 (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) 0-15 0 (Default) 00-44 00 (Default) *% B4D* Max. code length *% B4E* Min. code length *% B4F* Truncate leading *% B4G* Truncate ending *% B4H* Insert group number *% B4M* Exit setting mode *$$% * - 24 - • Standard 2 of 5 Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% B5A* Enable Check-sum verification Disable Default *% B5B* Enable Check-sum transmission Disable Default *% B5C* Enable Code ID setting Hex 00-FF ASCII 5 (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) 0-15 0 (Default) *% B5D* Max. code length *% B5E* Min. code length *% B5F* Truncate leading *% B5G* Truncate ending *% B5H* - 25 - Insert group number 00-44 *% B5M* Exit setting mode *$$% * - 26 - 00 (Default) • Code 128 Enter setting mode *% $$PRO* Function Option Remark Read Disable *% B6A* Enable Default Check-sum verification Disable *% B6B* Enable Check-sum transmission Disable Default Default *% B6C* Enable Code ID setting Hex 00-FF ASCII 6 (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) *% B6D* Max. code length *% B6E* Min. code length *% B6F* Truncate leading *% B6G* - 27 - Truncate ending 0-15 0 (Default) *% B6H* Format Standard Default *% B6R* UCC/EAN-128 Append Disable Default *% B6I* Enable UCC/EAN-128 ID setting Hex 00-FF ASCII 6 (Default) Hex 00-FF ASCII 1DH (Default) 00-44 00 (Default) *% B6Y* Field separator code *% B6Z* Insert group number *% B6M* Exit setting mode *$$% * - 28 - • CODABAR Enter setting mode *% $$PRO* Function Option Remark Read Disable *% B7A* Enable Check-sum verification Disable Default Default *% B7B* Enable Check-sum transmission Disable Default *% B7C* Enable Code ID setting Hex 00-FF ASCII 7 (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) *% B7D* Max. code length *% B7E* Min. code length *% B7F* Truncate leading *% B7G* - 29 - Truncate ending 0-15 0 (Default) *% B7H* Start/End type ABCD/ABCD Default abcd/abcd *% B7S* ABCD/TN*E abcd/tn*e Insert group number 00-44 00 (Default) *% B7M* Start/End transmission Disable *% B7J* Enable Exit setting mode *$$% * - 30 - Default • EAN 8 Enter setting mode *% $$PRO* Function Option Remark Read Disable *% B8A* Enable Default Check-sum transmission Disable *% B8C* Enable Default Code ID setting Hex 00-FF ASCII 8 (Default) 0-15 0 (Default) 0-15 0 (Default) *% B8D* Truncate leading *% B8G* Truncate ending *% B8H* Truncate leading zero Disable *% B8K* Enable - 31 - Default Supplement digits None Default 2 digits *% B8O* 5 digits Auto detection Insert group number 00-44 *% B8M* Exit setting mode *$$% * - 32 - 00 (Default) • EAN13 Enter setting mode *% $$PRO* Function Option Remark Read Disable *% B9A* Enable Default Check-sum transmission Disable *% B9C* Enable Default Code ID setting Hex 00-FF ASCII 9 (Default) 0-15 0 (Default) 0-15 0 (Default) *% B9D* Truncate leading *% B9G* Truncate ending *% B9H* Truncate leading zero Disable *% B9K* Enable - 33 - Default Supplement digits None Default 2 digits *% B9O* 5 digits Auto detection ISBN/ISSN Disable Default *% B9T* Enable Insert group number 00-44 *% B9M* Exit setting mode *$$% * - 34 - 00 (Default) • UPCA Enter setting mode *% $$PRO* Function Option Remark Read Disable *% BAA* Enable Default Check-sum transmission Disable *% BAC* Enable Default Code ID setting Hex 00-FF ASCII A (Default) 0-15 0 (Default) 0-15 0 (Default) *% BAD* Truncate leading *% BAG* Truncate ending *% BAH* Truncation/ Expansion None *% BAL* Not Send Zero Expand to EAN13 - 35 - Default Supplement digits None Default 2 digits *% BAO* 5 digits UCC/EAN 128 Auto detection Insert group number 00-44 *% BAM* Exit setting mode *$$% * - 36 - 00 (Default) • UPCE Enter setting mode *% $$PRO* Function Option Remark Read Disable *% BBA* Enable Default Check-sum transmission Disable *% BBC* Enable Default Code ID setting Hex 00-FF ASCII B (Default) 0-15 0 (Default) 0-15 0 (Default) *% BBD* Truncate leading *% BBG* Truncate ending *% BBH* Supplement digits None 2 digits *% BBO* 5 digits UCC/EAN 128 Auto detection - 37 - Default Insert group number 00-44 00 (Default) *% BBM* Expansion Disable Default *% BBN* Enable UPCE-1 Disable *% BBU* Enable Exit setting mode *$$% * - 38 - Default • MSI Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% BCA* Enable Check-sum verification Disable Mod 10 Default *% BCB* Mod 10/10 Mod 11/10 Check-sum transmission Disable Default *% BCC* Enable Code ID setting Hex 00-FF ASCII C (Default) 0-64 0 (Default) 0-64 0 (Default) *% BCD* Max. code length *% BCE* Min. code length *% BCF* - 39 - Truncate leading 0-15 0 (Default) 0-15 0 (Default) 00-44 00 (Default) *% BCG* Truncate ending *% BCH* Insert group number *% BCM* Exit setting mode *$$% * - 40 - • PLESSEY Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% BDA* Enable Check-sum verification Disable *% BDB* Enable Check-sum transmission Disable Default Default *% BDC* Enable Code ID setting Hex 00-FF ASCII D (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) *% BDD* Max. code length *% BDE* Min. code length *% BDF* Truncate leading *% BDG* - 41 - Truncate ending 0-15 0 (Default) 00-44 00 (Default) *% BDH* Insert group number *% BDM* Exit setting mode *$$% * - 42 - • China post Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% BEA* Enable Code ID setting Hex 00-FF ASCII E (Default) 0-64 11 (Default) 0-64 0 (Default) 0-15 0 (Default) 0-15 0 (Default) 00-44 00 (Default) *% BED* Max. code length *% BEE* Min. code length *% BEF* Truncate leading *% BEG* Truncate ending *% BEH* Insert group number *% BEM* - 43 - • Italian Pharmacode ( CODE 32 ) Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% BFA* Enable Code ID setting Hex 00-FF ASCII F (Default) 0-15 0 (Default) 0-15 0 (Default) *% BFD* Truncate leading *% BFG* Truncate ending *% BFH* Leading "A" Disable Default *% BFP* Enable Insert group number 00-44 *% BFM* Exit setting mode *$$% * - 44 - 00 (Default) • Matrix 2 of 5 Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% BGA* Enable Check-sum verification Disable Default *% BGB* Enable Check-sum transmission Disable Default *% BGC* Enable Code ID setting Hex 00-FF ASCII G (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) *% BGD* Max. code length *% BGE* Min. code length *% BGF* Truncate leading *% BGG* - 45 - Truncate ending 0-15 0 (Default) 00-44 00 (Default) *% BGH* Insert group number *% BGM* Exit setting mode *$$% * - 46 - • Telepen Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% BHA* Enable Check-sum verification Disable Default *% BHB* Enable Check-sum transmission Disable Default *% BHC* Enable Code ID setting Hex 00-FF ASCII H (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) 0-15 0 (Default) *% BHD* Max. code length *% BHE* Min. code length *% BHF* Truncate leading *% BHG* Truncate ending *% BHH* - 47 - Insert group Number 00-44 00 (Default) *% BHM* Format Numeric only *% BHR* Full ASCII only Exit setting mode *$$% * - 48 - Default • CODE11 Enter setting mode *% $$PRO* Function Option Read Disable Remark Default *% BIA* Enable Check-sum verification Disable *% BIB* One digit Default Two digit Check-sum transmission Disable Default *% BIC* Enable Code ID setting Hex 00-FF ASCII I (Default) 0-64 0 (Default) 0-64 0 (Default) 0-15 0 (Default) *% BID* Max. code length *% BIE* Min. code length *% BIF* Truncate leading *% BIG* - 49 - Truncate ending 0-15 0 (Default) 00-44 00 (Default) *% BIH* Insert group number *% BIM* Exit setting mode *$$% * - 50 - 4. String setting / Transmission • Prefix/Suffix Enter setting mode *% $$PRO* Function Prefix characters setting Option Remark Hex 00-FF ASCII 1-22 characters None (Default) Hex 00-FF ASCII 1-22 characters 0D0AH (Default) *% SZA* Suffix characters setting *% SZB* Exit setting mode *$$% * - 51 - • Preamble / Postamble Enter setting mode *% $$PRO* Function Preamble characters setting Option Remark Hex 00-FF ASCII 1-22 characters None (Default) *% SYA* Preamble transmission Disable Default *% SYB* Enable Postamble characters setting Hex 00-FF ASCII 1-22 characters None (Default) *% SYC* Postamble transmission Disable *% SYD* Enable Exit setting mode *$$% * - 52 - Default • Insert Group Character Enter setting mode *% $$PRO* Function Insert G1 characters setting *% SXA* Insert G2 characters setting *% SXB* Insert G3 characters setting Option Remark Hex 00-FF ASCII 1-22 characters None (Default) Hex 00-FF ASCII 1-22 characters None (Default) Hex 00-FF ASCII 1-22 characters None (Default) Hex 00-FF ASCII 1-22 characters None (Default) 00-63 00: no insertion (Default) 00-63 00: no insertion (Default) 00-63 00: no insertion (Default) 00-63 00: no insertion (Default) *% SXC* Insert G4 characters setting *% SXD* Insert data group 1 position *% SXE* Insert data group 2 position *% SXF* Insert data group 3 position *% SXG* Insert data group 4 position *% SXH* Exit setting mode *$$% * - 53 - • Others Enter setting mode *% $$PRO* Function Code ID position Option Before code data Remark Default *% SWA* After code data Code ID transmission Disable *% SWB* Default Proprietary ID AIM ID Code length transmission Disable Default *% SWC* Enable Code name transmission Disable Default *% SWD* Enable Case conversion Disable *% SWE* Upper case Lower case For barcode data only - 54 - Default Exit setting mode *$$% * - 55 - 5. Scanner configuration / Reset to default settings Enter setting mode *% $$PRO* Function Barcode standard parameter list *% LP1* Unique parameter list *% LP2* System parameter list *% LP3* String setting list *% LP4* Firmware version *% LFV* Description After scan this barcode, the host terminal/computer will display barcode standard parameter list of the scanner. After scan this barcode, the host terminal/computer will display unique parameter list of the scanner. After scan this barcode, the host terminal/computer will display system parameter list of the scanner. After scan this barcode, the host terminal/computer will display string setting list of the scanner. After scan this barcode, the host terminal/computer will display firmware version of the scanner. Reset to default settings *% RES* Initialize the scanner and restore the settings to factory default. Exit setting mode *$$% * - 56 - Parameter list Parameter Bar code 0 */0* 1 */1* 2 */2* 3 */3* 4 */4* 5 */5* 6 */6* 7 */7* 8 */8* 9 */9* A */A* B */B* C */C* D */D* E */E* F */F* - 57 - P/N: 39-0000073-20LF