Synchronizing controller
Parameter 744
Step width: In marker synchronization mode, Offset Parameter 740 is changed
by this value when Terminal 32 or Terminal 33 is activated.
Parameter 745
Slave speed factor: Record the factor by which the slave speed must be
multiplied, so that the desired value is displayed. To calculate the value use
the following formula:
Factor =
N Set * 400 * Slaveencoder _ resolution
60 * Display _ value
Example:
1
resolution 1024 increments, desired display 100 at 1500 /min
1
Inkr .
1500 min
* 400 * 1024 Umdr
.
= 102400
Factor =
60 * 100
Parameter 746
Master speed factor: Record the factor by which the master speed must be
multiplied, so that the desired value is displayed. To calculate the value use
the following formula:
Factor =
Parameter 747
N Set * 400 * Masterencoder _ resolution
60 * Display _ value
Synchronizing error display factor: Record the factor by which the error must
be multiplied, so that the desired value is displayed. To calculate the value,
use the following formula:
Factor =
N Set * 400 * Slaveencoder _ resolution
60 * Display _ value
Store your data settings by means of Store Input (I4) or by changing Parameter 710 to “1”.