Transcript
Micro-Master 4500 Plus User Guide Micro-Master 4500 Plus Filter Flush Timing Diagram PD switch must be closed longer than the Auto-Skip1 time before a Filter Flush cycle will start. (This will mask out any false filter cycles during pressure instability during valve changes. Controller ignores PD input during PD Delay PD Input At the End of a Filter Flush cycle, The Controller will ignore and PD input for the duration of Filter Cycle Delay Interstation Delay (0-99secs) PD Switch Delay programmable (0-99mins:99secs) Any P.D. Switch closure < Auto Skip1 time will be ignored Cycle Delay Programmable (0 to 99hrs:99mins) Filter 1 Runtime (0 to 99mins:99secs) Filter Stn. 1 Switch off Filter Stn 1 and wait for interstation delay before switching on Filter Stn. 2 To allow system to Stabilise Filter Stn. 2 Backup Delay programmable (0 to 99hrs:99mins) Filter 2 Runtime (0 to 99mins:99secs) Backup Delay Programmable (0-99hrs:99mins) If NO P.D. input for the User programmed Time, the Controller will initiate a Filter Flush Cycle. Time 3.2.6.2. Filter Cycle Delay – Minimum Time between Filter Flushing Cycles. This is the delay time between filter back-flush cycles. It Acts in conjunction with the PD switch and effectively delays a Pressure Differential induced flushing sequence for a period of time to allow system stabilization after the completion of a back-flush Cycle. A typical minimum delay would be 5 minutes when a PD switch is used. 3.2.6.3. P.D. Switch Backup Delay – Max. Time between Filter Flushing Cycles. The Filter program has a background timer to actuate a filter program cycle if an unusually long time has elapsed between a Pressure Differential initiated back-flush cycle. This guards against filter overload in the event of PD switch failure. 3.2.6.4. Filter Inter-Station Delay – Time between each filter station operating. This is the time delay between a filter station switching off and the next station switching on. A time between 0 to 99 seconds may be entered. This allows time for the system to stabilize before back-flushing the next filter. To Modem PC SERIAL G N D P D Connect N.O contacts of P.D switch across terminals P.D and Gnd. When no P.D Switch is used, i.e. the filter cycle to be time only operation, the P.D. input must be linked to the GND terminal as above. 14 Rev.0310