Download Micro-Master 4500 Plus User Guide Introduction Micro
Transcript
Micro-Master 4500 Plus User Guide 3.3.3 Flow Pulse Meter Setup Press the SENSORS key, then key 3 to Setup the Irrigation Flow Meter 1. Press key 1 to select the setup for the irrigation Pulse Meter. (Flow meter 1) Flow1 =1 Flow2=2 Flow3=3 Read/Reset FlowMeter END Enter the calibration for flow meter 1. In this example it is 1 pulse per cubic meter. PULSES/UNIT VOLUME = 1 Enter Pulses END=UNITS Press END then > to Setup the flow-rate units for this sensor. The following screen will be Litres< 1 CMetres 4 10L 2 100L 3 END=EXIT displayed. Select Key 1-4 to choose the units for the flow meter. The < will indicate the current setting selected for the units. END to Exit. Setting up Chemical Injection flow meters. The setup for the 2 chemical flow meter inputs can be setup in the same way by selecting 2 to select flow meter 2 (Chemical injection 1 Flow meter) and 3 to select flow meter 3 (Chemical injection 2 flow meter). 20 Rev.0310