Micro-Master 4500 Plus User Guide occurred. If an Injection error has occurred a i = injection error will be displayed. An Alarm output is switched on to indicate a fault has occurred. If a Communication options Chip is fitted, and Radio-Master valves are installed, the fault may be logged as C indicating a communication error to the valve. if a valve draws excessive current in the field, the faulty station is stored in the fault Data Base as E = electrical error. Manual Program Control Any station or program can be manually started., program advanced from station to station (or group to group), or the Irrigation can be paused from the keyboard. Plug-in terminal strip. The valve output field wiring does not need to be disconnected during servicing Simply unplug the terminal strip from relay board when servicing is required. Sensor inputs The controller require normally open switch inputs. Inputs are- Reset, Hold, Auto-skip, Program 1 Start input, Program 2 start input, pressure differential input for filter, Pulse Flow input for Irrigation, First chemical injection, Second chemical injection. Rain bucket input, and Alarm out for fault reporting. Communication protocols Communication protocols are RS232 (Direct RS232 or UHF Radio or Telephone or GSM ). OR RS485 (Direct RS485 or Radio-master) When communicating over a distance of 50m to 2km, or more than 1 controller use RS485, RadioMaster, UHF radio, Telephone or GSM communications to link the field controllers to the P.C for central programming and fault reporting. Direct RS485 Communications can be in excess of 2km with the use of a RS485 repeater. (Communication options Chip required for the above functions). Rain Sensor When a Rain sensor is fitted to 1 or more controllers, the measured rainfall can be logged and the results used to Rain-Switch 1 or more controllers within a network, and the resultant action sent by SMS to a GSM or CDMA mobile phone. (Communication options Chip required). Surge protection. Extensive mains and field surge protection. Relay outputs to field valves ensure reliable operation in the most harsh conditions. All Logic powered from an additional isolation transformer and to allow all logic to be tied directly to earth. Solar power option Allows a Micro-Master 4500 Plus to generate 24 VAC to operate standard solenoid valves from a 12 volt supply. This prevents cable damage due to corrosive DC current flowing through the cables causing electrolysis. The 24VAC inverter has been designed to have 0 volts DC component. 5 Rev.0310