occurred. If an Injection error has occurred a i = injection error will be displayed. An Alarm
output is switched on to indicate a fault has occurred. If a Communication options Chip is fitted,
and Radio-Master valves are installed, the fault may be logged as C indicating a communication
error to the valve.
if a valve draws excessive current in the field, the faulty station is stored in the fault Data Base as
E = electrical error.
Manual Program Control
Any station or program can be manually started., program advanced from station to station (or
group to group), or the Irrigation can be paused from the keyboard.
Plug-in terminal strip.
The valve output field wiring does not need to be disconnected during servicing Simply unplug
the terminal strip from relay board when servicing is required.
Sensor inputs
The controller require normally open switch inputs. Inputs are- Reset, Hold, Auto-skip, Program
1 Start input, Program 2 start input, pressure differential input for filter, Pulse Flow input for
Irrigation, First chemical injection, Second chemical injection. Rain bucket input, and Alarm out
for fault reporting.
Communication protocols
Communication protocols are RS232 (Direct RS232 or UHF Radio or Telephone or GSM ). OR
RS485 (Direct RS485 or Radio-master) When communicating over a distance of 50m to 2km, or
more than 1 controller use RS485, RadioMaster, UHF radio, Telephone or GSM communications
to link the field controllers to the P.C for central programming and fault reporting. Direct RS485
Communications can be in excess of 2km with the use of a RS485 repeater. (Communication
options Chip required for the above functions).
Rain Sensor
When a Rain sensor is fitted to 1 or more controllers, the measured rainfall can be logged and the
results used to Rain-Switch 1 or more controllers within a network, and the resultant action sent
by SMS to a GSM or CDMA mobile phone. (Communication options Chip required).
Surge protection.
Extensive mains and field surge protection. Relay outputs to field valves ensure reliable
operation in the most harsh conditions. All Logic powered from an additional isolation
transformer and to allow all logic to be tied directly to earth.
Solar power option
Allows a Micro-Master 4500 Plus to generate 24 VAC to operate standard solenoid valves from
a 12 volt supply. This prevents cable damage due to corrosive DC current flowing through the
cables causing electrolysis. The 24VAC inverter has been designed to have 0 volts DC
component.