Download Operating Instructions
Transcript
Operating Instructions Run testing 3 Phase appliances (Option) Overview The 3 Phase Run Test (where fitted) tests Portable 3 Phase Appliances in accordance with AS/NZS 3760. This option is available with 20 and/or 32A 3 phase sockets or other current ratings as requested. The test looks for an Earth Connection <= 1 Ohm; a run current to ensure the appliance is switched on and running; and a leakage current of <= 5mA. The test is a Long Run Test. It may be shortened at any time after the test commences by pressing “Reset” twice in quick succession. If any of the test parameters (Earth Current, Run Current or Leakage Current) fail, then the 3 phase test fails otherwise the Pro Logger will indicate a pass. Connection interface cable for 3 Phase Appliance Operation This test requires 2 connections to the Pro Logger: an earth return connection to the Device Under Test’s (DUT) chassis; and a connection the 20 or 32A 3 phase socket adaptor (this is a ‘din’ type socket in the well of the Pro Logger II). The 3 phase socket adaptor is plugged into a 3 phase power source, then the DUT into the 3 phase adaptor. The DUT should be running to conduct a test. To test a 3 phase extension lead, run a test with the extension lead connected between an already tested (and known electrically safe) 3 phase appliance and the 3 phase adaptor. Select the appropriate 3 Phase Run Test option from the OTHER APPLIANCE menu; use the F1 and F2 keys to scroll up and down the list of options. 3 Phase Run Test Connect to Utility Socket Connect to 3 Phase supply Earth Return Lead 3 phase supply for the Device Under Test 21 SafeTcheck Pro Logger II