Download installation manual
Transcript
New features and functions Chime Mode Any selected section can cause output 4 to give a pulse output to drive a sonalert or screamer when that section is unsealed. Setup by function 84. Keyswitch operation Select up to six sections (from sections 11-16) to arm or disarm (and panic) by a momentary or latching trigger of the section. Separate combinations of areas can be selected to be controlled by each keyswitch input and the opening and closings report via users 81-86. Securitel Line Fail Backup to Dialler or GSM Function 59 (backup account number) and Function 70 (Delay to backup) added to enable line fault detection on STU line to cause the reporting to use an alternate format. CID via dialler / GSM. Tape or Domestic Tape dial allows the panel to report to a standard phone or mobile. Upload / DownLoad Allows remote programming via modem and retrieval of history (up to 2000 events) Short Cuts Here are some related functions which may help in programming the Panel Keypad Codes Functions Functions Time Functions Section Setup Area Setup Dialler Down load Securitel Dead Man Timer Printer Special Functions Keyswitch Functions Chime sections Functions Functions Functions Functions Functions Functions Functions Functions Functions Functions Functions 54, 58, 74 00- 30 and 99 with Tech Code 00- 80 with Master Code 40, 41, 42, 73, 97, 98 49, 50, 52, 53, 55, 56, 57, 61, 75 31, 32, 33, 34, 35, 36, 58 60, 61, 63, 66, 67, 69, 71, 72, 73, 74, 76 60, 62, 66 60, 61, 63, 67, 71, 72, 74, 76 44, 45, 46, 57 94, 96 54, 58, 74, 81-88 37, 81-86 (delete sections used from 31-36) 84 - output on OP4 Notes 1. Day Local Sections - only generate local sirens, bells and strobes when in Day Mode (i.e. the area is disarmed). 2. Open / Close Reports can be enabled / disabled for each area 1-6. Individual area reporting may not be required if Full system Close and Open is required. Area 7 can be separately selected to report first to open, last to close messages. 3. When programming user code areas or privileges: Area 9 is used to allow the user access to the test functions. Area 10 is used to allow the user to isolate sections. 4. User Codes 81-86 are reserved as keyswitch users for inputs 11-16 see function 37 5. To enter program or test modes, all areas must be in the off mode. Page 1 (C) Copyright 2002 MCM Electronics Pty Ltd