System and Error Messages 40655: Axis is not independent The axis is not in independent mode. Check: It is only possible to get the status from an axis in independent mode. 40656: Execution error Not possible to set a new scale value for the AO signal. Check: The internal process, that control the output of the AO signal, are for some unknown reason "dead 40657: Execution error The output of the AO signal are not TCP-speed proportional any more. The reason could be following: Check: - Use of MoveX between TriggX instr. - No setup of TriggSpeed in the used TriggX instr. - The used ScaleLag is too small in relation to actual robot servo lag. 40658: Parameter error Parameter %s can only be used, if parameter %s is greater than zero. Check: Parameter %s has effect only in the first TriggX, in a sequence of several TriggX, that controls the speed proportional AO signal. 40659: Undefined load WARNING: Argument %.16s has undefined load (mass equal to 0 kg). IMPORTANT TO DEFINE CORRECT LOAD to avoid mechanical damages of the robot and to get good motion performance. Check: Define the actual load for the tool or the grip load before program movement or jogging. User’s Guide/BaseWare OS 3.1 40660: Undefined load WARNING: Argument %.16s has undefined load centre of gravity. IMPORTANT TO DEFINE CORRECT LOAD to avoid mechanical damages of the robot and to get good motion performance. Check: Define the actual centre of gravity for the tool load or the grip load before program movement or jogging (cog.x, cog.y and cog.z can not be 0 mm at the same time 40661: Search error The signal %.16s for the SearchX instruction is already high at the start of searching. 40662: Invalid worldzone type The switch %.16s must be associated with a %.16s worldzone. Check: If use of switch Temp, the datatype must be wztemporary in WorldZone. If use of switch Stat, the datatype must be wzstationary in WorldZone. 40663: World zone not in use The ’%.16s’ argument of the instruction %.16s must refer to a worldzone that has been defined and activated by a WZLimSup or WZDOSet instruction. 40664: World zone already in use The ’%.16s’ worldzone has already been defined and activated. A world zone can only be defined once. Check: Use a worldzone with another name. 40665: Too many world zones It is not possible to add the world zone %.16s. The world zone table is full Check: 16-73
Related documents
Programmierung und Test
EXJSET™ - AMETEK Power Instruments
JEMREAD - Progos
same in room - 5axes
Migrating from an Agilent 4284A LCR Meter to an Agilent
PUA 1 ver 3
Aristo
Aristo U82 - Benvenuto nel sito personale di Massimo Capurro
Axis 540plus Product manual
to read more about this robot
Batch Reactor Manual 1 – Atlas Systems
ELECTRICAL TROUBLESHOOTING MANUAL