Download INSTALLATION MANUAL
Transcript
INSTALLATION MANUAL Four-way Cassette Type Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep it for future reference. CONTENTS PAGE PRECAUTIONS........................................................................................1 INSTALLATION INFORMATION................................................................2 INSPECTING AND HANDLING THE UNIT.................................................2 ATTACHED FITTINGS..............................................................................3 INDOOR UNIT INSTALLATION.................................................................4 INSTALL THE CONNECTING PIPE...........................................................6 REFRIGERANT PIPE CONNECTION..........................................................7 CONNECT THE DRAIN PIPE.....................................................................8 Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock and fire. When installing the unit in a small room, take measures against to keep refrigerant concentration from exceeding allowable safety limits in the event of refrigerant leakage. Contact the place of purchase for information. Excessive refrigerant in a closed ambient can lead to oxygen deficiency. Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set to fall, water leakage, electrical shock fire. WIRING...................................................................................................9 CONTROL..............................................................................................10 TROUBLE SHOOTING............................................................................12 TEST OPERATION.................................................................................12 Install at a strong and firm location which is able to withstand the set' s weight. If the strength is not enough or installation is not properly done, the set will drop to cause injury. The appliance must be installed 2.3m above floor. The appliance shall not be installed in the laundry. Before obtaining access to terminals, all supply circuits must be disconnected. 1. PRECAUTIONS Be sure to be in conformity with the local, national and international laws and regulations. Read "PRECAUTIONS" carefully before installation. The following precautions include important safty items. Observe them and never forget. Keep this manual with the owner's manual in a handy place for future reference. The safty precautions listed here are divided into two categories. In either case, important safty information is listed which must be read carefully. WARNING Failure to observe a warning may result in death. CAUTION Failure to observe a caution may result in injury or damage to the equipment. After completing the installation, make sure that the unit operates properly during the start-up operation. Please instruct the customer on how to operate the unit and keep it maintained.Also, inform customers that they should store this installation manual along with the owner's manual for future reference. WARNING Be sure only trained and qualified service personnel to install, repair or service the equipment. Improper installation, repair, and maintenance may result in electric shocks, short-circuit, leaks, fire or other damage to the equipment. The appliance must be positioned so that the plug is accessible. The enclosure of the appliance shall be marked by word, or by symbols, with the direction of the fluid flow. For electrical work, follow the local national wiring standard, regulation and this installation instructions. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect in electrical work, it will cause electrical shock and fire. Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection. Wiring routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock. If the supply cord is damaged, it must be replaced by the manufacture or its sevice agent or a similarly qualified person in order to avoid a hazard. An all-pole disconnection swith having a contact separation of at least 3mm in all poles should be connected in fixed wiring. When carrying out piping connection, take care not to let air substances go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury. Do not modify the length of the power supply cord or use of extension cord, and do not share the single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock. The temperture of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube. installation manual 1 Carry out the specified installation work after taking into account strong winds, typhoons or earthquakes. Improper installation work may result in the equipment falling and causing accidents. 2. INSTALLATION INFORMATION If the refrigerant leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into the place contacting with fire. To install properly, please read this "installation manual" at first. After completing the installation work, check that the refrigerant does not leak. Toxic gas may be produced if the refrigerant leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker. When installing the indoor unit or its tubing, please follow this manual as strictly as possible. The air conditioner must be installed by qualified persons. If the air conditioner is installed on a metal part of the building, it must be electrically insulated according to the relevant standards to electrical appliances. When all the installation work is finished, please turn on the power only after a thorough check. CAUTION Ground the air conditioner. Do not connect the ground wire to gas or water pipes,lightning rod or a telephone ground wire.Incomplete grounding may result in electric shocks. Regret for no further announcement if there is any change of this manual caused by product improvement. INSTALLATION ORDER Be sure to install an earth leakage breaker. Failure to install an earth leakage breaker may result in electric shocks. Select the location; Connect the outdoor unit wires , then connect the indoor unit wires. You are not allow to connect the air conditioner with the power source until wiring and piping the air conditioner is done. Install the outdoor unit; While following the instructions in this installation manual, install drain piping in order to ensure proper drainage and insulate piping in order to prevent condensation. Improper drain piping may result in water leakage and property damage. Wiring; Install the indoor and outdoor units, power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise. Depending on the radio waves, a distance of 1 meter may not be sufficient enough to eliminate the noise. The appliance is not intended for use by young children or infirm persons without supervision. Install the indoor unit; Install the connecting pipe ; Connect the drain pipe; Test operation. 3. At delivery, the package should be checked and any damage should be reported immediately to the service agent. When handling the unit, take into account the following: 1 Fragile, handle the unit with care. Keep the unit upright in order to avoid compressor damage. Don't install the air conditioner in the following locations: There is petrolatum existing. INSPECTING AND HANDLING THE UNIT 2 Choose on before hand the path along which the unit is to be brought in. 3 Move this unit as originally package as possible. 4 When lifting the unit , always use protectors to prevent belt damage and pay attention to the position of the unit’s centre of gravity. There is salty air surrounding (near the coast). There is caustic gas (the sulfide, for example) existing in the air (near a hot spring). The Volt vibrates violently (in the factories). In buses or cabinets. In kitchen where it is full of oil gas. There is strong electromagnetic wave existing. There are inflammable materials or gas. There is acid or alkaline liquid evaporating. Other special conditions. installation manual 2 4. ATTACHED FITTINGS Please check whether the following fittings are of full scope. If there are some spare fittings, please restore them carefully. Four-way Cassette Four-way Cassette (compact) 1. Expansible hook 4 4 2. Installation hook 4 4 3. Installation paper board 1 1 4. Bolt M6 4 5. Soundproof / insulation sheath 2 2 6. Out-let pipe pipe 1 1 7. Out-let pipe sheath 1 NAME INSTALLATION FITTINGS Tubing & Fittings SHAPE 8. Out-let pipe clasp Drainpipe Fittings 1 1 9. Tightening band 20 20 10. Remote controller 1 1 1 1 12. Mounting screw (ST2.9×10-C-H) 2 2 13. Alkaline dry batteries (AM4) 2 2 1 1 15. Signal line 1 1 16. Connective pipe for restriction assembly 1 1 Remote controller & Its Frame 11. Frame 14. Installation manual Others This manual Cautions on remote controller installation: Never throw or beat the controller. SET TEMPERATURE(°C) Before installation, operate the remote controller to determine its location in a reception range. SWING VENT ON/OFF ECONOMIC RUNNING RESET FAN SPEED TIMER LOCK CANCEL Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove. Note that the positive and negative poles are right positions when loading batteries. This manual is subject to changes due to technological improvement without further notices. Mounting screw B ST2.9x10-C-H TEMP MODE Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment. (it is necessary to prevent image disturbances or noise interferences.) FAN HIGH MED LOW AUTO COOL DRY HEAT Remote controller holder Remote controller Fig.4-1 installation manual 3 5. INDOOR UNIT INSTALLATION 3 Please adjust the hexangular nuts on the four installation hooks evenly, to ensure the balance of the body. 5.1 Installation place If the drainpipe is awry, leakage will be caused by the malfunction of the water-level switch. (Refer to Fig.5-1,Fig.5-2,Fig.5-3 for specification.) Adjust the position to ensure the gaps between the body and the four sides of ceiling are even. The body's lower part should sink into the ceiling for 10~12 mm (Refer to Fig.5-5). The indoor unit should be installed in a location that meets the following reauirements: The ceiling is horizontal, and its structure can endure the weight of the indoor unit. Use the transparent hose filled with water to check the lever of the main body from the four sides or diagonal line direction, the lever indicator also can check the lever from four sides of the main body .(Refer to Fig.5-6) The outlet and the inlet are not impeded, and the influence of external air is the least. Locate the air conditioner firmly by wrenching the nuts after having adjusted the body's position well. There is enough room for installation and maintenance. The air flow can reach throughout the room. The connecting pipe and drainpipe could be extracted out easily. There is no direct radiation from heaters. CAUTION Keep indoor unit, outdoor unit, power supply wiring and transmission wiring at least 1 meter away from televisions and radios. This is to prevent image interference and noise in those electrical appliances. (Noise may be generated depending on the conditions under which the electric wave is generated, even if 1 meter is kept.) New built houses and ceilings 1 In the case of new built house, the hook can be embedded in advance (refer to the A.b mentioned above). But it should be strong enough to bear the indoor unit and will not become loose because of concrete shrinking. 2 After installing the body, please fasten the installation paper board onto the air conditioner with bolts(M6X16) to determine in advance the sizes and positions of the hole opening on ceiling.(Refer to Fig.5-8) Please first guarantee the flatness and horizontal of ceiling when installing it. Refer to the A.a mentioned above for others. 3 Refer to the A.c mentioned above for installation. 5.2 Install the main body 4 Remove the installation paper board. The existing ceiling (to be horizontal) 1 Please cut a quadrangular hole of 600×600mm in the ceiling according to the shape of the installation paper board. (Refer to Fig.5-3,Fig.5-4) The center of the hole should be at the same position of that of the air conditioner body. CAUTION After installing the body, the four bolts(M6x12)must be fastened to the air conditioner onto ensure the body is grounded well. Determine the lengths and outlets of the connecting pipe, drainpipe and cables. 2 Necessary room A 280 To balance the ceiling and to avoid vibration, please enforce the ceiling when necessary. Please select the position of installation hooks according to the hook holes on the installation board. Outlet If the ceiling is extremely high, please determine the length of the installation hook according to facts. Inlet Outlet Ground Fig.5-1 >1000 Face the concave side of the installation hooks toward the expansible hooks. Determine the length of the installation hooks from the height of ceiling, then cut off the unnecessary part. >2300 Drill four holes of Ø12mm, 50~50mm deep at the selected positions on the ceiling. Then embed the expansible hooks (fittings). >1000 Cut the installation hook open in the middle position, then use apropriate length of reinforcing rod (Ø12) to weld together. >1000 >1000 The length could be calculated from Refer to Fig.5-5: Length=210+L(in general, L is half of the whole length of the installation hook) Fig.5-2 installation manual 4 A NOTE 570(Body) All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner you purchased(depend on model).The actual shape shall prevail. 647(Panel) 523(Hook-location) 60 Drain side 5.3 Install The Panel CAUTION 545(Hook-location) 570(Body) Never put the panel face down on floor or against the wall, or on bulgy objects. (Unit: mm) 647(Panel) Fig.5-3 Never crash or strike it. A Hook Body 50 Ceiling Remove the air-in grill. Slide two grill switches toward the middle at the same time, and then pull them up. (Refer to Fig.5-9) 26 0 Nut 1 Draw the grill up to an angle of about 45, and remove it. (Refer to Fig.5-10) Panel 600 Fig.5-4 176 10-12 L H(ceiling height) 34 Body Grid switch Fig.5-9 Ceiling Fig.5-5 45 Colourless trans parent pipe Horizontal indicator Fig.5-10 Fig.5-6 2 Install the panel Align the swing motor on the panel to the tubing joints of the body properly. ( Refer to Fig.5-11) Hang the four fixed rope of the main body to the installation cover and the other three covers of the swing motor: (Refer to Fig.5-11 and ) CAUTION Fig.5-7 Body Fixing hole installation paper board The installation cover of the swing motor must sink into the corresponding water receiver. Central hole Hook hole Screw M5x16 (Accessory) Installation paper board Fig.5-8 installation manual 5 Install the panel on the main body with bolt (M5×16) and washer. (Refer to Fig.5-11 ) 6. Adjust the four panel hook screws to keep the panel horizontal, and screw them up to the ceiling evenly. Regulate the panel in the direction of the arrow in Fig.5-11. slightly to fit the panel's center to the center of the ceiling's opening. Guarantee that hooks of four corners are fixed well. INSTALL THE CONNECTING PIPE Check whether the height drop between the indoor unit and outdoor unit, the length of refrigerant pipe, and the number of the bends meet the following requirements: ● The max height drop and The length of refrigerant pipe deponding on the ouotdoor unit.(If the height drop is more than 10m, you had better put the outdoor unit over above the indoor unit.) ● The number bends fewer than 15 ● Do not let air, dust, or other impurities fall in the pipe system during the time of installation. If the gap between the panel and ceiling still exists after fastening the screws, the height of the indoor unit should be modified again. ( Refer to Fig.5-14-left) ● The connecting pipe should not be installed until the indoor and outdoor units have been fixed already. You can modify the height of the indoor unit through the openings on the panel's four corners, if the lift of the indoor unit and the drainpipe is not influenced (Refer to Fig.5-14-right). ● Keep the connecting pipe dry, and do not let moisture in during installation. Keep fastening the screws under the panel hooks, until the thickness of the sponge between the body and the panel's outlet has been reduced to about 4~6mm. The edge of the panel should contact with the ceiling well. (Refer to Fig.5-12) Malfunction described in Fig.5-13 can be caused by inappropriate tightness the screw. The Procedure of Connecting Pipes Measure the necessary length of the connecting pipe, and make it by the following way. 3 Hang the air-in grill to the panel, then connect the lead terminator of the swing motor and that of the control box with corresponding terminators on the body respectively. ● Connect the indoor unit at first, then the outdoor unit. 4 Relocate the air-in grid in the procedure of reversed order, install the air-in grid. ① Bend the tubing in proper way. Dont harm them. ② Daub the surfaces of the flare pipe and the joint nuts with frozen oil, and wrench it for 3~4rounds with hands before fasten the flare nuts. (Refer to Fig.6-1) ③ Be sure to use two wrenches simultaneously when you connect or disconnect the pipes. ● The stop valve of the outdoor unit should be closed absolutely (as original state). Every time you connect it, first loosen the nuts at the part of stop valve, then connect the flare pipe immediately (in 5 minutes). If the nuts have been loosened for a long time, dusts and other impurities may enter the pipe system and may cause malfunction later. So please expel the air out of the pipe with refrigerant before connection. ● Expel the air (refer to the “Expel The Air”) after connecting the refrigerant pipe with the indoor unit and the outdoor unit.Then fasten the nuts at the repair-points. Drain side Steel rope Steel rope 1 2 1 3 2 Swing motor installation cover 3 Cover Swing motor installation cover Cover 3 Swing motor side Please operate according to the direction of the arrow, or it can not be disassembled when it is necessary. Fig.5-11 Body Ceiling Bolt, washer 4 Inlet air Panel sealing foam Panel foam2 Panel foam Outlet air Fig.5-12 Ceiling Leakage Air plate Notices For Benable pipe. Panel Panel foam1 ● The bending angle should not exceed 90°C ● Bending position is preferably in the bendable pipe. The larger the better it is . ● Do not bend the pipe more than three times. Bend the connecting pipe of small wall thickness. Dew ● Cut out a desired concave at the bending part of the insulating pipe. ● Then expose the pipe(cover it with tapes after bending). ● To prevent collapsing of deforming, please bend the pipe at its biggest radius. ● Use bender to get a small radius pipes. Fig.5-13 Hexagon nut Horizontal adjust ment Ceiling Fig.5-14 installation manual 6 Use the market brass pipe. Be sure to use the same insulating materials when you buy the brass pipe. (More than 9mm thick). 90 °± 4 45 ° ±2 A Use frozen oil R0.4~0.8 Fig.7-2 Fig.6-1 Table.7-1 Bend the pipe with thumb A(mm) Outside diameter Fig.6-2 Make the ends straight Fig.6-3 Locate The Pipe Max Min Φ6.4mm 8.7 8.3 Φ9.5mm 12.4 12.0 Φ12.7mm 15.8 15.4 Φ15.9mm 19.0 18.6 Φ19.1mm 23.3 22.9 Fasten the nut ● Drill a hole in the wall (suitable just for the size of the wall conduit, 90mm in general), then set on the fittings such as the wall conduit and its cover. ● Put the connecting tubing at the proper position, wrench the nuts with hands then fasten it with a wrench. (Refer to Fig.7-3) ● Bind the connecting pipe and the cables together tightly with binding tapes. Do not let air in, which will cause water leakage by condensation. ● Too large torque will harm the bellmouthing and too small will cause leakage. Please determine the torque according to Table.7-2. ● Pass the bound connecting pipe through the wall conduit from outside. Be careful of the pipe all ocation to do no damage to the tubing. Connect the pipes. Then, open the stem of stop valves of the outdoor unit to make the refrigerant pipe connecting the indoor unit with the outdoor unit fluently flow. Be sure of no leakage by checking it with leak detector or soap water. Cover the joint of the connecting pipe to the indoor unit with the sound proof/insulating sheath (fittings), and bind it well with the tapes to prevent leakage. 7. REFRIGERANT PIPE CONNECTION Fig.7-3 Table.7-2 Tubing size Torque Φ6.4mm 14.2~17.2N.m Φ9.5mm 32.7~39.9N.m Φ12.7mm 49.5~60.3N.m Φ15.9mm 61.8~75.4N.m Φ19.1mm 97.2~118.6N.m 7.1 Expel The Air Flaring ● Cut a pipe with a pipe cutter. ● Insert a flare nut into a pipe and flare the pipe. Lean crude burr 90 Fig.7-1 installation manual 7 7.2 Check The Leakage The necessary filling amount of refrigerant ● Refrigerant volume to be added is calculated according to outdoor unit installation manual .Be sure to add refrigerant measuring by a scale. L: The length of the pipe ● Please record the quantity added and store it carefully for future maintenance. Check all the joints with the leak detector or soap water. (See Fig.7-6 as a reference illustration) Check-point of indoor unit D C B A Expel the air with a vacuum pump (Refer to Fig.7-4) (Please refer to its manual for the way of using manifold valve) ● Loosen and remove the maintenance nuts of stop valves A and B, and connect the charge hose of the manifold valve with the maintenance terminator of stop valve A. (Be sure that stop valves A and B are both closed) ● Connect the joint of the charge hose with the vacuum pump. ● Open the Lo-lever of the manifold valve completely. ● Turn on the vacuum pump. At the beginning of pumping, loosen the maintenance terminator nut of stop valve B a little to check whether the air comes in (the sound of the pump changes, and the indicator of compound meter turns below zero). Then fasten the nut. ● When the pumping has finished, close the Lo-lever of the manifold valve completely and turn off the vacuum pump. ● When you have pumped for over 15 minutes, please confirm that the indicator of multimeter is on -1.0X105Pa (-76cmHg) ● Loosen and remove the quadrangle cover of stop valves A and B to open stop valve A and B completely, then fasten them. Check-point of outdoor unit A......Lo-stop valve B......Hi-stop valve C,D..Joints of the connecting pipe to the indoor unit. Fig.7-6 7.3 Insulation Be sure to with insulating materials cover all the exposed parts of the flare pipe joints and refrigerant pipe on the liquid-side and the gas-side. Ensure that there is no gap between them. Incomplete insulation may cause water condensation. ● Disassemble the charge hose from the repair-mouth of stop valve A, and fasten the nut. 8. CONNECT THE DRAIN PIPE Manifold valve Multi-meter 8.1 Install The Drainpipe Of The Indoor Unit Pressure meter -76 cmHg Lo-lever 1) The drainpipe can use PVC pipe (external diameter about 37~ 39mm, inner diameter is 32mm). Hi-lever Charge hose Charge hose 2) Joint drainpipe connector to the end side of water pumping pipe, and fix drainpipe together with water outflow pipe and thermal insulation tube by clasp of water outflow pipe (attached). Vacuum pump Lo-lever Fig.7-4 All the stop valves should be opened before test operation. Each air conditioner has two stop valves of different sizes on the side of the outdoor unit which operate as Lo-stop value, respectively. (Refer to Fig.7-5) CAUTION Don’t use forcing strength to crack the water-pumping pipe. 3) Water-pumping pipe and drainpipe from main body must be wrapped by insulation tube evenly, and bound by tighten band for obstructing air getting in and coagulation. Flare nut 4) Prevent from water backflow into unit inside during shutdown, the drain pipe shall place down side and drain water to outdoor (drain side), the gradient of the drain pipe should be higher than (1/100), without salient and water remain.(Refer to Fig.8-1 a) Stopper Cap Valve body Valve stem Fig.7-5 installation manual 8 5) When connecting drainpipe, don’t drag the pipe that would pull the main unit. For this, please arrange bearing points every 0.8 to 1.0 meter to avoid pipe be bended (See Fig.8-1 b). 8.2 Drainage Test Check whether the drainpipe is unhindered 6) When connect a lengthen drainpipe, apply protective tube to wrap its indoor parts for ensuring the lengthen part connected tightly. New built house should have this test done before paving the ceiling. 1 Remove the test cover, and stow water of about 2000ml to the water receiver through the stow tube. 7) In case the drainpipe outlet is higher than pumping connective pipe of the main body, the drainpipe must be arranged upwards vertically by using connective assembly of the water outlet for vertical bending, and the height of the drainpipe shall set to the defrosting pan surface no more than 600mm, otherwise, too much backflow while shutdown would leads to overflow (Refer to Fig.8-2). 2 Turn on the power, and operate the air conditioner under the "COOLING" mode. Listen to the sound of the drain pump. Check whether the water is discharged well (a lag of 1min is allowed before discharging, according to the length of the drain pipe), and check whether water leaksfrom the joints. 8) Base on the actual requirement to bend piping, and use connective assembly of water outlet in terminal box for pipe layout. CAUTIONS: If there is any malfunction, please resolve it immediately. CAUTION The joints in drain system must be sealed to avoid water leakage. 3 Stop the air conditioner for there minutes, check if everything is ok. If the drain hose is located unreasonable, water overflow will cause the Alarm indicator lamp flashing (For both cooling and heating type or cooling only type), even the water leak out from the water receiver. 9) The height from floor to the end of drainpipe or the bottom of drain slot must more than 50 mm. Don’t immerse the end of drainpipe or the bottom of drain slot into water. When drain condensate liquid to raceway, please bend the drainpipe to a U-sharped hydroseal for avoiding stench transmitted by drainpipe to indoor. 4 Check the drain pump whether drain water immediately when alarm sound for the high water lever. If the water lever can't come down below to the limited water lever, the air conditioner will stop. Restart it until turn off the power and drain off all the water. 5 0.8~1.0 m The drain plug is used to empty the water-receiver for maintenance of the air conditioner. Please stuff it imposition at all times during operation to avoid leakage. Gradient: higher than 1/100 9. a Turn off the power, drain the water away. WIRING Caution >1.0 m ● The air conditioner should use separate power supply with rated voltage, the voltage of power supply must be within90%~110% of rated value. ● The external power supply to the air conditioner should have ground wiring, which is linked to the ground wiring of the indoor and outdoor unit. ● The wiring work should be done by qualified persons according to circuit drawing. ● A disconnection device having an air gap contact separation in all active conductors should in corporated in the fixed wiring according to the National wiring regulation. ● Be sure to locate the power wiring and the signal wiring well to avoid cross-disturbance and their contact with connecting pipe or stop valve body. ● The wiring attached to this air conditioner is 6m long. Be sure to prolong it with wiring of the same type and proper length if necessary. Generally, do not twist two wiring together unless the joint is soldered well and covered with insulator tape. ● Do not turn on the power until you have checked carefully after wiring. ● The yellow and green wire can only be used to link to the ground wiring. b Fig.8-1 0.8-1.0m Lean over 1/100 Max. 600mm <200mm Pump-pipe clasp (the fittings) Fig.8-2 The Specification of Power installation manual 9 Table.9-1 Model(W) 2200~5600 Phase Power Terminal board diagram Please refer to the indoor unit wiring diagram for the wiring. 1-Phase 220-240~50Hz 208-230~60Hz Frequency and volt NOTE The air-conditioners can connect with Central Control Monitor (CCM). Before operation, please wiring correctly and set system address and network address of indoor units. Circuit breaker/fuse (A) 15/15 Indoor unit power wiring (mm2) 3×2.0 Indoor/outdoor connecting wiring(mm2) (weak electric signal) 3-core shielded wire 3×0.5 XT1 L Y/G N CAUTION A disconnection device having an air gap contact separation in all active conductors should be incorporated in the fixed wiring according to the National Wiring Regulation. TO INDOOR POWER 220-240V~50Hz 208-230V~60Hz Fig.9-2 XT2 Power (220-240V ~ 50Hz) (208-230V ~ 60Hz) X Y P E GRAY BLACK YELLOW BLACK Wiring chart BLUE WHITE Ground the air conditioner properly to obtain a good antiinterference effect . Y/G Q I NDOOR UNIT I NDOOR UNIT CENTRAL CONTROL MONITOR(CCM) TO OUTDOOR To Central Control Monitor COMM. BUS (CCM)COMM. BUS Please use 3-core shielded wire,and connect the shielded layer to the earth COMPUTER The reserved function is indicated in broken line table, users can select it when necessary OUTDOOR UNIT I NDOOR UNIT Fig.9-3 Wire controller Display board To wire controller The reserved wire control function is indicated in broken table, user can purchase the wire controller when necessary. 3-core shielded wire Fig.9-1 Fig.9-4 NOTE 10. CONTROL A, B≤20m A Distance between outdoor unit and the farthest indoor unit ≤1200m (Note: The length of signal wire depends on actual wiring condition, not longer than 1200m) Outdoor Unit installation manual 10 EF 0 B Unit Entrance of the outdoor Unit D ENC1 Indoor Entrance of the Indoor Unit PO WER_S 123 4 This chart is just an on-site wire-connecting example. For details, please refer to relative National criteria. Hoursepower code ABC Connect the grounded wire to both indoor and outdoor units; Hoursepower set 789 We consider the minimal size of the metal core as the wire size. So it is recommended you adopt a thicker one as the power conducting wire so as to avoid power decrease; 56 Please remember the surroundings (environmental temperature, direct sunlight, rain etc.) Base on different purposes to setting the switch cords on PC panel of indoor electrical control box. Once finish the setting, please cut off the main power, and then input power again, otherwise, setting function could not work. ENC1 Dial switch Code Note: The horsepower has been set before leaving the factory , which can only be modified by professionals. Horsepower setting Network address set Capacity(Horsepower) 0 2200W(0.8HP) 1 2800W(1.0HP) 2 3600W(1.2HP) 3 4500W(1.5HP) 4 5600W(2.0HP) ● Network address is set by communication of indoor and outdoor unit; the address is the same as indoor address, there is no need to set separately. ● The central control of indoor units can be done on outdoor unit, there is no need to control indoor unit separately, for details please refer to V4+ outdoor unit manual. ● For previous control of indoor units, the network can be set by connecting (X,Y,E) terminals, there is no need to set network address. The network can also be set by outer network module and main board (CN20). CAUTION The system together have 64units(0-63),everyone has only system addresscode,If two addresses are the same in one system , the abnormal operation will occur. Please switch off the power before setting,otherwise the unexpected error will occur. Main board Code designation SW1 definition ON ON ON SW1 1234 SW1 1234 SW1 ● 1 means factory test mode ● 0 means add. auto searching mode ON (default setting) ● 1 means DC fan is chosen ● 0 means AC fan is chosen SW1 1234 ON SW1 ● 10 means DC fan static pressure is 2 1234 ● 00 means DC fan static pressure is 0 (reserved) ● 01 means DC fan static pressure is 1 (reserved) ON 1234 SW1 1234 (reserved) ● 11 means DC fan static pressure is 3 (reserved) SW2 definition ON ON ON ON S W2 12 34 S W2 12 34 S W2 12 34 S W2 12 34 ● 00 means the temperature is 15 degrees when shutting down the unit for cold wind proof. ● 01 means the temperature is 20 degrees when shutting down the unit for cold wind proof. ● 10 means the temperature is 24 degrees when shutting down the unit for cold wind proof. ● 11 means the temperature is 26 degrees when shutting down the unit for cold wind proof. ON SW2 ● 00 means the time of stopping 1234 ON SW2 TERMAL fan is 4 minutes ● 01 means the time of stopping TERMAL fan is 8 minutes 1234 ON ON SW2 ● 10 means the time of stopping TERMAL fan is 12 minutes 1234 SW2 1234 ● 11 means the time of stopping TERMAL fan is 16 minutes SW5 definition ON SW 5 ● 00 means temperature compensation is 6 degrees under heating mode ON 1 2 ON ● 10 means temperature compensation is 4 degrees under heating mode 1 2 SW 5 ● 01 means temperature compensation is 1 2 SW5 2 degrees under heating mode ON SW5 ● 11 means temperature compensation is 8 degrees under heating mode 1 2 installation manual 11 SW6 definition 12. TEST OPERATION SW6 ON ● 1 means auto wind under auto mode 1 2 ON The test operation must be carried out after the entire installation has been completed. ● 0 means auto wind under non auto mode Please confirm the following points before the test operation: SW6 reserved 1 2 J1,J2 definition J1 J1 no Jumpers means power off memory function J1 J1 Jumpers means no power off memory function J2 reserved 11. TROUBLE SHOOTING ● The indoor unit and outdoor unit are installed properly. ● Tubing and wiring are correctly completed. ● The refrigerant pipe system is leakage-checked. ● The drainage is unimpeded. ● The heating insulation works well. ● The ground wiring is connected correctly. ● The length of the tubing and the added stow capacity of the refrigerant have been recorded. ● The power voltage fits the rated voltage of the air conditioner. ● There is no obstacle at the outlet and inlet of the outdoor and indoor and indoor units. ● The gas-side and liquid-side stop values are both opened. ● The air conditioner is pre-heated by turning on the power. Test operation Set the air conditioner under the mode of “COOLING”with the remote controller, and check the following points per the “Owner’s Manual”If there is any malfunction, please resolve it as per chapter “Troubles And Causes ”. Table.12-1 NO. Type Contents LED Lamp flash Remarks 1 The evaporator The run lamp sensor check flashes fast Malfun- point is abnomal ction or room temp. sensor is abnormal. 2 Indoor/outdoor unit The timer lamp After the malfunctions Malfun- communication flashes fast disappear, it restores ction is abnormal automatically. 3 4 5 6 7 8 Outdoor unit Malfun- is abnormal ction After the malfunctions disappear, it restores automatically. ● Whether the switch on the remote controller works well. Whether the buttons on the remote controller works well. Whether the air flow louver moves normally. Whether the room temperature is adjusted well. The alarm lamp After the malfunctions flashes slowly disappear, it restores automatically. Whether the indicator lights normally. Whether the temporary buttons works well. After the malfunctions Malfun- Water level switch The alarm lamp disappear, it restores is abnormal flashes fast ction automatically. Alarm Mode conflict Alarm M_Home mismatching Defrost LED flash Malfunction EEPROM error slowly Alarm Whether the drainage is normal. Whether there is vibration or abnormal noise during operation. When the indoor unit The defrost lamp turns to heating mode flashes fast or is turned off, the alarm will disappear. 4 LED flash togather The indoor unit When the indoor unit is replaced with a correct one , the alarm will disappear After the malfunctions disappear, it restores automatically. No address Timer LED and After the malfunctions when first time run LED flash disappear, it restores automatically. power on togather Whether the air conditioner heats well in the case of the HEATING/COOLING type. ● The outdoor unit Whether there is vibration or abnormal noise during operation. Whether the generated wind, noise, or condensed of by the air conditioner have influenced your neighborhood. Whether any of the refrigerant is leaked. CAUTION Protection function will delay the startup of compressor for 3 minutes in case the unit is turned on immediately after power on or restarted after shutdown. installation manual 12 MDV10I-029AW 202000171572