Download User Manual
Transcript
UIM242XX Miniature Integrated Stepper Motor Controller 6.1 General Introduction of Motion Control Modes There are three motion control modes for UIM242XX controller: Velocity Tracking (VT), Position Tracking (PT) and Position Velocity Tracking (PVT). Velocity Tracking (VT) In the Velocity Tracking (VT) mode, UIM242XX controller controls the motor speed to track desired speed. Figure 6-1 Velocity Tracking Speed Instruction “SPD=1000;” received at this point 1000 Basic motion control, speed rises without acceleration process Current Speed Advanced motion acceleration control, linear/non-linear T (Time) Speed Current Speed -1000 Instruction “SPD= - 1000;” received at this point Basic motion control, speed falls without deceleration process Advanced motion control, linear/nonlinear deceleration T (Time) Please note that: Sign (+/-) of the value of SPD instruction instructs the motion direction. For example: both the instruction “SPD=1000;” and “SPD=+1000;” make motor run forward at 1000pps. Meanwhile, the instruction “SPD= -1000;” can cause motor to run backward at 1000pps. The DIR instruction is obsoleted. However, if a DIR instruction occurs after an SPD instruction, it will still affect motor direction. If Advanced Motion Control Module is installed, speed control can be achieved through linear or nonlinear acceleration/deceleration. For details, please refer to Chapter 6.0 Advanced Motion Control. Position Tracking (PT) In the Position Tracking (PT) mode, UIM242 controller will keep motor running at a speed close to the set value until it reaches the desired steps. After setting the desired speed, user can enter desired positions or incremental displacement continuously or discontinuously. UIM242 controller will make sure that the desired position is achieved when trying to approach the desired speed to the greatest extent. As shown in Figure 6-2, UIM242 controller operates in PT mode automatically on receiving position instruction such as POS, STP or QEC until an instruction of “STP=0;” is given. STP is a displacement control instruction. Logically “STP=0;” means no displacement. It is contradictory to send a displacement instruction of no displacement. Therefore, UIM242 will take this instruction as a request to shift from PT mode to VT mode. UI Robot Technology Co. Ltd. M42110923EN Page 21