1 Heat source 2 Expansion reservoir 3 Protecting pipeline 4 Expansion pipeline 5 Overflow pipeline 6 Filling pipeline 7 Water level limiter 8 Return pipeline Figure No. 3 – Examples of connecting the open expansion reservoirs 5.4. Surplus heat removal equipment The two-way safety valve DBV 1 - 02 serves for removing the surplus heat in case the boiler water temperature exceeds 95°C. This two-way safety valve is connected to boiler flanges as shown in the figure No. 5. If the system is fitted with the two-way safety valve DBV 1 – 02 and the boiler becomes overheated (incoming water temperature is higher than 95°C), the two-way safety valve creates a cold water cycle until the temperature decreases below the limit value. At this moment, the discharge cooling equipment and inlet of cold water being added into the system are closed simultaneously. Figure No. 4 – Two-way safety valve DVB 1 - 02