Burner Removal
There should be no need to remove the burner during installation.
Removal of the burner during installation will invalidate the
warranty. Speak to our technical department. If the burner needs to
be removed at anytime for repair follow the steps below:
To Remove Burner:
•
•
•
•
•
•
•
•
•
Remove the fascia.
Isolate the gas supply.
Remove the lower vanity cover.
Disconnect the gas pipe from the injector [15mm nut].
Disconnect the 4mm pilot gas pipe from the top of the remote valve
[10mm nut].
Remove the Glass Panel.
Remove the screws within the burner enclosure which mount the
burner to the chassis.
Slide the burner out carefully to ensure the chassis and the valve is not
damaged. When it is far enough out unplug the ignition from the pilot
and disconnect the thermocouple from the end of the valve.
The burner is not completely separated.
To Refit Burner:
•
•
Follow the same procedure in reverse.
Once assembled check for gas leaks and commission the appliance.