Download INSTALLATION MANUAL
Transcript
b. Leakage detector alarming device FILL THE NAME OF CONNECTED SYSTEM To clearly identify the connected systems between two or more indoor units and outdoor unit, select names for every system and record them on the nameplate on the outdoor electric control box cover. related to mechanical ventilator Indoor unit OA Model (indoor unit) Room Name E.g.: Indoor unit (A) of the first system on second floor is recorded as: 2F 1A. CAUTION ON REFRIGERANT LEAKAGE This air conditioner adopts R22 as refrigerant, which is safe and noncombustible. The room for air conditioner should be big enough that refrigerant leakage can not reach the critical thickness. Besides this, you can take some action on time. Critical thickness the max thickness of Freon without any harm to person. R22 critical thickness:0.3 [ kg/m3 ] a. Ventilation peristome (Leakage detector alarming device should be installed in places easily keeping refrigerant) TURN OVER TO CUSTOMER The owner's manuals of indoor unit and outdoor unit and Service manual must be turned over to the customer. Particularize the contents in the owner's manual to the customers. Outdoor unit Dimension and the quantity of electric wire Name Indoor unit Room full of leaking refrigerant (All the refrigerant has leaked) Type Signal wire of indoor/ 2-core outdoor unit Size 0.75mm2 500m RVVP-0.75mmx2 2 1. Signal wire of indoor/outdoor unit adopts 2-core shielded wire which has polarity. For least interference, the closed Calculate the critical thickness through following ends of shield wire should be connected continuously and steps, and take necessary actions. the shielding layer should be connected to the end E on 1. Calculate the sum of the charge volume (A[kg]) outdoor terminal block. Total refrigerant volume= refrigerant volume when 2. 5-core shield wire is used for wire controller (terminals delivered(13[kg])+superaddition A, B, C, D and E) 3 2. Calculate the indoor cubage (B[m ]) (as the 3. The controlling between indoor and outdoor units is minimum cubage) realized by RS485 communication, and the address is 3. Calculate the refrigerant thickness set while installation. A [ kg] 3 Critical thickness 0.3 [ kg/m ] B [ m3 ] Countermeasure against overhigh thickness CAUTION 1. Install mechanical ventilator to reduce the refrigerant Signal wire of indoor/outdoor unit and wiring thickness under critical level. (ventilate regularly) of wire controller belong to low voltage circuit, 2. Install leakage detector alarming device related to which should not contact power cord with high mechanical ventilator if you can not regularly voltage. ventilate.