Download INSTALLATION MANUAL

Transcript
MS SPEED MASTER DOOR CONTROL - FAULT CODES
Frequency Inverter
FAULT CODES
CODE CAUSE
UU LOW VOLTAGE SUPPLY
CHECK
THE MAINS VOLTAGE IS TOO LOW
OU
OVER VOLTAGE
OH
OVER HEATING INSIDE THE PANEL
EITHER,THE MAINS VOLTAGE IS TOO HIGH OR THE
DECELERATION IS TOO FAST,REDUCE PARAMETER 9.
THE INVERTER IS TOO HOT.CHECK VENTILATION.
CHECK PARAMETER J*=1.
THE DRIVE IS OVERLOADED
OC1 THE MOTOR CURRENT EXCEEDS
THE INVERTER RATING BY 210%
OC2 THE MOTOR CURRENT EXCEEDS
THE INVERTER RATING BY 150%
FOR MORE THAN 30 SEC
OC3 OVER CURRENT WHILST
ACCELERATING
OC4 OVER CURRENT WHILST
DC BRAKING OPERATES
THE INVERTER OR THE DRIVE ARE OVERLOADED.
CHECK FOR OBSTRUCTIONS,
CHECK THE OPERATOR SELECTION.
THE ACCELERATION IS TOO FAST,
REDUCE PARAMETER 7
THE DC BRAKING IS TOO STRONG.
REDUCE PARAMETER H*
OC5 SEVERE OVERLOAD
CHECK FOR A SHORT, OR THE MOTOR IS STALLED,
BRAKE NOT RELEASING,
OR PARAMETER B IS SET TOO HIGH
THIS IS OK FOR A FEW SECONDS, BUT SHOULD
NOT CONTINUE. THE CURRENT IS HIGHER THAN
THE RATED CURRENT OF THE INVERTER
50.5 DISPLAY FLASHES.
THE CURRENT IS EXCEEDING
THE RATING OF THE INVERTER
E01 MECHANICAL OVERLOAD
(SLIP MONITORING) OR MISSING
SIGNAL FROM THE ENCODER
E02 DIRECTION ERROR
E03 NO SIGNAL FROM THE ENCODER (ONLY DURING INSTALLATION)
THE CONNECTIONS TO THE PANEL AND
FOR MECHANICAL OBSTRUCTION.
E04 THE WRONG BUTTON HAS
BEEN OPERATED
E05 THE REFERENCE SWITCH IS
SHORTED OR BROKEN
THE POSITION OF THE REFERENCE POINT
Door Control
E06 THE REFERENCE SWITCH OPERATES
IN THE WRONG POSITION
THE REFERENCE SWITCH
Control Input
E07 RUN TIME EXCEEDED
IF USING AN INCREMENTAL ENCODER THE
REFERENCE SWITCH HAS OPERATED IN THE WRONG
POSITION OR IF USING LIMIT SWITCHES THE
PRE-CLOSE LIMIT IS OPEN CIRCUIT.
CHECK THE SETTING OF PARAMETER 6*.
E08 THE SAFETY EDGE TEST HAS FAILED
E09 FAULT ON THE SAFETY EDGE
E10 THE SAFETY EDGE HAS OPERATED.
CHECK THE CONNECTIONS TO THE SAFETY EDGE.
CHECK THE CONNECTIONS TO THE SAFETY EDGE.
THE SAFETY EDGE HAS OPERATED
E12 THE TORQUE LIMIT IS EXCEEDED
CHECK PARAMETER B**. THIS SHOULD BE =0.
E13 THE PARAMETERS ARE LOCKED
E14 COMMUNICATIONS ERROR WITH
THE ABSOLUTE LIMIT SWITCH
E15 ERROR DURING ‘QUICK STEP’
INSTALLATION.
ENTER THE CORRECT J CODE TO UNLOCK THE CONTROL.
CHECK THE WIRING TO THE ABSOLUTE RESISTOR
LIMIT SWITCH.
J11
OPEN INPUT CHECK IP 11
THE INPUT IS ACTIVE. CHECK THE INPUT DEVICE.
J12
J13
CLOSE INPUT CHECK IP 12
PART OPEN CHECK IP 13
THE INPUT IS ACTIVE. CHECK THE INPUT DEVICE.
THE INPUT IS ACTIVE. CHECK THE INPUT DEVICE.
J14
GO INPUT CHECK IP 14
THE INPUT IS ACTIVE. CHECK THE INPUT DEVICE.
J15
STOP INPUT CHECK IP 15
THE INPUT IS ACTIVE. CHECK THE INPUT DEVICE.
J17
STOP INPUT CHECK IP 17
THE INPUT IS ACTIVE. CHECK THE INPUT DEVICE.
J21
STOP/REV INPUT CHECK IP 21
THE ALIGNMENT FOR THE PHOTO CELLS
REF REFERENCE RUN REQUIRED
20
THE MOTOR DIRECTION IS INCORRECT
THE CONNECTIONS TO THE PANEL AND
FOR MECHANICAL OBSTRUCTION.
TRY
USE THE DISPLAY (0**=2) TO SHOW THE VOLTAGE AT THE
INVERTER. THE RANGE IS 292-357
USE THE DISPLAY (0**=2) TO SHOW THE VOLTAGE AT THE
INVERTER. THE RANGE IS 292-357
USE THE DISPLAY (0**=8) TO SHOW THE TEMPERATURE OF
THE POWER STAGE. RANGE IS 850 TO 650
USE THE DISPLAY (0**=1) TO SHOW THE CURRENT.
CHECK FOR MECHANICAL DAMAGE OR OBSTRUCTION.
CHECK THE DRIVE SELECTION.
USE THE DISPLAY (0**=1) TO SHOW
THE DAMAGE OR OBSTRUCTION.
CHECK THE DRIVE SELECTION.
USE THE DISPLAY (0**=1) TO SHOW THE CURRENT.
REDUCE ACCELERATION PARAMETER 7
USE THE DISPLAY (0**=1) TO SHOW THE CURRENT.
REDUCE THE DC BRAKING CURRENT AND CHECK THE
RELAY TOLERANCE PARAMETER E
USE THE DISPLAY (0**=1) TO SHOW THE CURRENT.
CHECK FOR MECHANICAL DAMAGE OR OBSTRUCTION.
CHECK THE DRIVE SELECTION.
USE THE DISPLAY (0**=0) TO SHOW THE POSITION.
MOVE THE DOOR MANUALLY AND ENSURE THAT
THE POSITION VALUE HAS CHANGED IN THE DISPLAY.
SWAPPING THE GREEN AND YELLOW ENCODER WIRES.
USE THE DISPLAY (0**=0) TO SHOW THE POSITION. MOVE
THE DOOR MANUALLY AND ENSURE THAT THE POSITION
VALUE HAS CHANGED IN THE DISPLAY.
THIS ERROR CAN OCCUR DURING THE SET UP PROCEDURE.
TRY TO START TO RUN TO THE REFERENCE POSITION AGAIN.
THIS ERROR OCCURS IF 8**=1 I.E MONITORED REFERENCE
SWITCH IS USED AND THE SWITCH IS DAMAGED.
USE THE DISPLAY(0**=5) THE VALUE SHOULD BE 102-921
CHECKING THAT THE VALUE OF PARAMETER D IS CORRECT.
THE RUN TIMER SHOULD BE SET TO 3 SECOND LONGER
THAN THE TIME TAKEN TO CLOSE THE DOOR/GATE.
THIS CODE WILL WILL BE LATCHED AFTER 3 OPERATIONS.
RESET BY OPERATING IN DEADMAN OR SWITCHING OFF
THE POWER.
IF THE TORQUE LIMIT IS BEING USE CHECK FOR OBSTRUCTIONS
WHILST OPENING. OTHERWISE SET B**=0 TO TURN IT OFF.
TRY TO REPEAT THE QUICK STEP INSTALLATION.
REMOVING THE INPUT WIRE. IF THE FAULT CLEARS CHECK
THE SWITCH.
REMOVING THE INPUT WIRE. IF THE FAULT CLEARS CHECK
THE SWITCH.
REMOVING THE INPUT WIRE. IF THE FAULT CLEARS CHECK
THE SWITCH.
REMOVING THE INPUT WIRE AND FITTING A LINK TO
TERMINAL 16. IF THE FAULT CLEARS CHECK THE SWITCH.
REMOVING THE INPUT WIRE AND FITTING A LINK TO
TERMINAL 18. IF THE FAULT CLEARS CHECK THE SWITCH.
REMOVING THE INPUT WIRE AND FITTING A LINK TO
TERMINAL 19. IF THE FAULT CLEARS CHECK THE SWITCH.
OPERATE A CONTROL INPUT TO TAKE THE
DOOR/GATE TO IT’S REFERENCE POSITION
Motion Systems Limited, Lower Hall Farm, Common Lane, Lower Stretton, Warrington, Cheshire WA4 4PE
T: +44 (0)870 600 0986 | F: +44 (0)870 600 0987 | E: [email protected] | W: www.motion-systems.co.uk
Brochure Designed & Produced by Division Design Ltd / 01606 888252