Document Update PowerFlex 700 User Manual Update This document provides new information for the PowerFlex 700 Series B User Manual (publication 20B-UM002A-EN-P). Included is new information pertaining to Frames 5 & 6, NEMA Type 12 drives. Place this document with your User Manual for future reference. Dimensions Figure 1 Frame 5 NEMA Type 12 Standalone 609.6 (24.00) 25.4 (1.00) 558.8 (22.00) 105.5 (4.15) Air Outlet 1574.8 (62.00) DANGER REMOTE SOURCE(S) OF POWER. DISCONNECT ALL SOURCES OF POWER BEFORE OPENING THE DOOR. DANGER 1543.0 ±1.5 (62.75 ±0.06) ELECTRICAL SHOCK HAZARD FROM ENERGY STORAGE CAPACITORS. VERIFY LOW VOLTAGE DISCHARGE BEFORE SERVICING. SEE INSTRUCTION MANUAL. 1061.5 (41.79) 140.0 (5.51) 16.8 (0.66) 13.5 (0.53) Dia. 4 Places (See Note A) 450.7 (17.75) Max. 12.7 (0.50) Dia. Lifting Holes Note A: Mount with 0.50 Inch UNC Grade 5 or Higher Screws or M12 Material Class 5.6 or Higher Screws Use Flat Washer with each Fastener 425.5 (16.75) 287.0 (11.30) Air Inlet Frame Dimensions are in millimeters and (inches) 5 (1) Approx. Weight (1) kg (lbs.) Description Standalone Drive 102.51 (226.0) Drive & Packaging 154.68 (341.0) Weights include HIM and Standard I/O. 2 PowerFlex 700 User Manual Update Figure 2 Frame 5 NEMA Type 12 Flange Mount 500.0 (19.69) 219.5 (8.64) 196.5 (7.74) 11.0 (0.43) 12.7 (0.50) Dia. Lifting Holes - 4 Plcs. 478.0 (18.82) Air Outlet 1061.0 (41.77) 127.6 (5.02) SHLD 1039.0 (40.91) SHLD 449.6 (17.74) BRAKE TERMINAL RATINGS WIRE RANGE: 14-1/0 AWG (2.5-50 MM2) TORQUE: 32 IN-LB (3.6 N-M) STRIP LENGTH: 0.67 IN (17 MM) DANGER 300 VDC EXT PWR SPLY TERM (PS+, PS-) WIRE RANGE: 22-10 AWG (0.5-4 MM2) TORQUE: 5.3 IN-LB (0.6 N-M) STRIP LENGTH: 0.35 IN (9 MM) RISK OF ELECTRIC SHOCK AND DEATH GROUND TERMINAL RATINGS (PE) WIRE RANGE: 6-1/0 AWG (18-35 MM2) TORQUE: 44 IN-LB (5 N-M) STRIP LENGTH: 0.83 IN (21 MM) DANGER POWER & DC TERMINAL RATINGS USE 75 C CU WIRE ONLY WIRE RANGE: 4-3/0 AWG (18-70 MM2) TORQUE: 133 IN-LB (15 N-M) STRIP LENGTH: 1.02 IN (26 MM) FIELD INSTALLED OPTIONS OUTPUT 6 MM HEX KEY INPUT AC 6 MM HEX KEY 53.2 (2.09) 194.0 (7.60) Ground M5 PEM Nut 11.0 (0.43) 5.5 (0.22) Dia. Holes for Supplied Mounting Hardware 40 Plcs. 303.6 (11.95) 2.3 (0.09) Compressed Gasket 185.0 (7.30) 97.0 (3.82) 384.0 (15.12) 42.0 (1.65) Frame Dimensions are in millimeters and (inches) 5 (1) Approx. Weight (1) kg (lbs.) Description Flange Mount Drive 61.69 (136.0) Drive & Packaging 81.65 (180.0) Weights include HIM and Standard I/O. PowerFlex 700 User Manual Update 3 Figure 3 Frame 5 Flange Mount - Cutout 1039.0 (40.91) 3.78 (0.149) Dia. Holes (40 Places) in Minimum 14 GA. (1.9) Steel Mounting Surface. Deburr Pilot Holes and Drive Cutout. 458.0 (18.03) 10.0 (0.39) 1026.5 (40.41) 948.5 (37.34) 870.5 (34.27) 792.5 (31.20) Cutout 714.5 (28.13) 1019.0 (40.12) 636.5 (25.06) 558.5 (21.99) 480.5 (18.92) 402.5 (15.85) 324.5 (12.78) 246.5 (9.71) 168.5 (6.63) 90.5 (3.56) 12.5 (0.49) 59.0 (2.32) 131.0 (5.16) Dimensions are in millimeters and (inches) 10.0 (0.39) 203.0 (7.99) 275.0 (10.83) 347.0 (13.66) 419.0 (16.50) 478.0 (18.82) 4 PowerFlex 700 User Manual Update Figure 4 Frame 6 NEMA Type 12 Standalone 711.3 (28.00) 24.1 (0.90) 663.1 (26.10) 123.6 (4.90) 1828.8 (72.00) 1795.2 (70.70) 1279.5 (50.40) 283.3 (11.20) 16.8 (0.66) 12.7 (0.50) Dia. Lifting Holes 13.5 (0.53) Dia. 4 Places (See Note A) 487.8 (19.20) Max. Note A: Mount with 0.50 Inch UNC Grade 5 or Higher Screws or M12 Material Class 5.6 or Higher Screws Use Flat Washer with each Fastener Air Inlet 8.0 (0.30) Frame Dimensions are in millimeters and (inches) 6 (1) Approx. Weight (1) kg (lbs.) Description Standalone Drive 176.90 (390.0) Drive & Packaging 229.07 (505.0) Weights include HIM and Standard I/O. PowerFlex 700 User Manual Update 5 Figure 5 Frame 6 NEMA Type 12 Flange Mount 584.0 (23.00) 556.0 (21.90) 201.0 (7.90) 14.0 (0.60) 105.8 (4.17) 1100.0 (43.30) 1078.0 (42.40) WIRE STRIP 22-12 AWG PS+ 5.3 IN-LB PS(0.6 N-M) 763.3 (30.0) BR2 BR1 DC+ DC- U T1 V T2 W T3 PE PE R L1 S L2 T L3 OUTPUT USE 75C COPPER WIRE ONLY, TORQUE 52 IN-LB (6 N-M) Ground M5 PEM Stud 11.0 (0.43) 137.2 (5.40) 127.3 (5.00) 5.5 (0.22) Dia. Holes for Supplied Mounting Hardware 44 Places 294.7 (11.60) 2.4 (0.10) Compressed Gasket 193.7 (7.60) 131.6 (5.20) 468.2 (18.40) 57.9 (2.30) Frame Dimensions are in millimeters and (inches) 6 (1) Approx. Weight (1) kg (lbs.) Description Flange Mount Drive 99.79 (220.0) Drive & Packaging 119.75 (264.0) Weights include HIM and Standard I/O. 6 PowerFlex 700 User Manual Update Figure 6 Frame 6 Flange Mount - Cutout 3.78 (0.149) Dia. Holes (44 Places) in Minimum 14 GA. (1.9) Steel Mounting Surface. Deburr Pilot Holes and Drive Cutout. 12.0 (0.50) 532.0 (20.90) 1078.0 (42.40) 1043.0 (41.10) 971.0 (38.20) 899.0 (35.40) 827.0 (32.60) 755.0 (29.70) Cutout 1054.0 (41.5) 683.0 (26.90) 611.0 (24.10) 539.0 (21.20) 467.0 (18.40) 395.0 (15.60) 323.0 (12.70) 251.0 (9.90) 179.0 (7.00) 107.0 (4.20) 35.0 (1.40) 44.0 (1.70) 12.0 (0.50) 122.0 (4.80) 200.0 (7.90) 278.0 (10.90) 356.0 (14.00) 434.0 (17.10) 512.0 (20.20) Dimensions are in millimeters and (inches) Ratings Fuse and ratings information have been added for these drives on the following pages. 0 0 0 0 0 0 1 1 2 2 3 3 3 4 5 5 5 6 6 6 20BC1P3 20BC2P1 20BC3P5 20BC5P0 20BC8P7 20BC011 20BC015 20BC022 20BC030 20BC037 20BC043 20BC056 20BC072 20BC085 20BC105 20BC125 20BC140 20BC170 20BC205 20BC260 0.37 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 – 55 – 55 – 75 – 90 – 110 – 132 – 0.25 0.55 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 – 37 – 45 – 45 – 55 – 75 – 90 – 110 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 2 2 50 50 50 50 50 50 50 50 50 50 50 50 50 45 45 50 (9) 50 (9) 50 (9) 50 (9) 40 (9) 40 (9) 50 (9) 50 (9) 40 (9) 40 (9) 45 (9) 50 (9) 1.1 1.8 3.2 4.6 7.9 10.8 14.4 20.6 28.4 35.0 40.7 53 68.9 81.4 68.9 100.5 81.4 121.1 91.9 136 101 164 136 199 164 255 199 0.77 1.3 2.2 3.2 5.5 7.5 10.0 14.3 19.7 24.3 28.2 36.7 47.8 56.4 47.8 69.6 56.4 83.9 63.7 93.9 69.6 126 103 148 126 177 138 1.3 2.1 3.5 5.0 8.7 11.5 15.4 22 30 37 43 56 72 85 72 105 85 125 96 140 105 170 140 205 170 260 205 1.4 2.4 4.5 5.5 9.9 13 17.2 24.2 33 45 56 64 84 94 108 116 128 138 144 154 157 187 210 220 255 286 308 1.9 3.2 6.0 7.5 13.2 17.4 23.1 33 45 60 74 86 112 128 144 158 170 163 168 190 190 255 280 289 313 390 410 3 3 6 6 15 15 20 30 35 45 60 70 90 110 90 125 110 150 125 200 150 250 200 250 250 350 250 3 6 7 10 17.5 25 30 45 60 80 90 125 150 200 175 225 175 275 200 300 225 375 300 450 375 550 450 3 3 6 6 15 15 20 30 35 45 60 70 90 110 90 125 110 150 125 200 150 250 200 250 250 350 250 6 8 12 20 30 45 60 80 120 125 150 200 250 300 275 400 300 500 375 400 300 600 550 600 600 750 600 15 15 15 20 30 45 60 80 120 125 150 200 250 300 300 300 300 375 375 400 300 500 400 600 500 750 600 3 3 7 7 15 15 20 30 50 50 60 100 100 150 100 150 150 250 150 250 150 250 250 400 250 400 400 M-C2E-B16 M-C2E-B25 M-C2E-B40 M-C2E-B63 M-C2E-C10 M-C2E-C16 M-C2E-C20 M-C2E-C25 – – – – – – – – – – – – – – – – – – – – M-D8E-B25 M-D8E-B40 M-D8E-B63 M-D8E-C10 M-D8E-C16 M-D8E-C20 M-D8E-C25 – – – – – – – – – – – – – – – – – – – – – – – M-F8E-C10 M-F8E-C16 M-F8E-C20 M-F8E-C25 M-F8E-C32 M-F8E-C45 – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – Motor Dual Circuit kW PWM Input Element Time Non-Time Circuit 140M Motor Starter with Adjustable Current Rating Freq. Temp. Ratings Output Amps Delay Fuse Delay Fuse Breaker (3) Protector (4) Range (5)(6) ND HD kHz °C Amps kVA Cont. 1 Min. 3 Sec. Min. (1) Max. (2) Min. (1) Max. (2) Max. (8) Max. (8) Available Catalog Numbers - 140 . . . (7) 400 Volt AC Input Drive Catalog Number Frame Table A.C 400 Volt AC Input Protection Devices (See page 11 for Notes) PowerFlex 700 User Manual Update 7 0 0 0 0 0 0 1 1 2 2 3 3 3 4 5 5 6 6 6 20BD1P1 20BD2P1 20BD3P4 20BD5P0 20BD8P0 20BD011 20BD014 20BD022 20BD027 20BD034 20BD040 20BD052 20BD065 20BD077 20BD096 20BD125 20BD156 20BD180 20BD248 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 – 75 – 100 – 125 – 150 – 200 – 0.33 0.75 1.5 2 3 5 7.5 10 15 20 25 30 40 – 50 – 60 – 75 – 100 – 125 – 150 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 2 2 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 (9) 50 (9) 50 (9) 50 (9) 50 (9) 50 (9) 50 (9) 50 (9) 45 (9) 50 (9) 0.9 1.6 2.6 3.9 6.9 9.5 12.5 19.9 24.8 31.2 36.7 47.7 59.6 72.3 59.6 90.1 72.3 117 90.1 147 131 169 147 233 169 0.7 1.4 2.2 3.2 5.7 7.9 10.4 16.6 20.6 25.9 30.5 39.7 49.6 60.1 49.6 74.9 60.1 97.6 74.9 122 109 141 122 194 141 1.1 2.1 3.4 5.0 8.0 11 14 22 27 34 40 52 65 77 65 96 77 125 96 156 125 180 156 248 180 1.2 2.4 4.5 5.5 8.8 12.1 16.5 24.2 33 40.5 51 60 78 85 98 106 116 138 144 172 188 198 234 273 270 1.6 3.2 6.0 7.5 12 16.5 22 33 44 54 68 80 104 116 130 144 154 163 168 234 250 270 312 372 360 3 3 4 6 10 15 17.5 25 35 40 50 60 80 100 80 125 100 150 125 200 175 225 200 300 225 3 6 8 10 15 20 30 50 60 70 90 110 125 170 125 200 170 250 200 350 250 400 350 550 400 3 3 4 6 10 15 17.5 25 35 40 50 60 80 100 80 125 100 150 125 200 175 225 200 300 225 6 8 12 20 30 40 50 80 100 125 150 200 250 300 250 350 300 500 350 600 500 600 600 700 600 15 15 15 20 30 40 50 80 100 125 150 200 250 300 250 350 300 375 350 450 375 500 450 700 500 3 3 7 7 15 15 20 30 50 50 50 70 100 100 100 125 100 150 125 250 250 250 250 400 250 M-C2E-B16 M-C2E-B25 M-C2E-B40 M-C2E-B63 M-C2E-C10 M-C2E-C16 M-C2E-C16 M-C2E-C25 – – – – – – – – – – – – – – – – – – – M-D8E-B40 M-D8E-B63 M-D8E-C10 M-D8E-C16 M-D8E-C16 M-D8E-C25 – – – – – – – – – – – – – – – – – – – – – M-F8E-C10 M-F8E-C16 M-F8E-C16 M-F8E-C25 M-F8E-C32 M-F8E-C45 M-F8E-C45 – – – – – – – – – – – – – – – – – – – – – -CMN-2500 -CMN-4000 -CMN-4000 -CMN-4000 -CMN-6300 -CMN-9000 -CMN-9000 -CMN-9000 – -CMN-9000 – – – – – – – – Motor Dual Circuit HP PWM Input Element Time Non-Time Circuit 140M Motor Starter with Adjustable Current (3) Protector (4) Range (5)(6) Rating Freq. Temp. Ratings Output Amps Delay Fuse Delay Fuse Breaker (1) (2) (1) (2) (8) (8) ND HD kHz °C Amps kVA Cont. 1 Min. 3 Sec. Min. Max. Min. Max. Max. Max. Available Catalog Numbers - 140 . . . (7) 480 Volt AC Input Drive Catalog Number Frame Table A.D 480 Volt AC Input Protection Devices (See page 11 for Notes) 8 PowerFlex 700 User Manual Update 20BE144 20BE125 20BE099 20BE1P7 20BE2P7 20BE3P9 20BE6P1 20BE9P0 20BE011 20BE017 20BE022 20BE027 20BE032 20BE041 20BE052 20BE062 20BE077 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 – 5 100 – 6 125 – 6 150 – 0 0 0 0 0 1 1 2 2 3 3 3 4 5 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 – 60 – 75 – 100 – 125 4 4 4 4 4 4 4 4 4 4 4 4 2 2 2 2 2 2 2 2 2 50 50 50 50 50 50 50 50 50 50 50 50 50 50 (9) 50 (9) 40 (9) 40 (9) 50 (9) 50 (9) 50 (9) 50 (9) 1.3 2.1 3.0 5.3 7.8 9.9 15.4 20.2 24.8 29.4 37.6 47.7 58.2 72.3 58.2 92.9 72.3 117 93 135 117 1.4 2.1 3.1 5.5 8.1 10.2 16.0 21.0 25.7 30.5 39.1 49.6 60.5 75.1 60.5 96.6 75.1 122 96.6 141 122 1.7 2.7 3.9 6.1 9 11 17 22 27 32 41 52 62 77 63 99 77 125 99 144 125 2 3.6 4.3 6.7 9.9 13.5 18.7 25.5 33 40.5 48 61.5 78 85 94 109 116 138 149 158 188 2.6 4.8 5.9 9.2 13.5 18 25.5 34 44 54 64 82 104 116 126 126 138 188 198 216 250 2 3 6 9 10 15 20 30 35 40 50 60 80 90 90 125 100 150 125 175 150 4 6 9 12 20 25 40 50 60 70 90 110 125 150 125 200 175 250 200 300 275 2 3 6 9 10 15 20 30 35 40 50 60 80 90 90 125 100 150 125 175 150 6 10 15 20 35 40 60 80 100 125 150 200 225 300 250 375 300 375 375 400 375 15 15 15 20 30 40 50 80 100 125 150 200 225 300 250 375 300 375 375 400 375 3 3 7 15 15 15 20 30 50 50 100 100 100 100 100 150 100 250 150 250 250 M-C2E-B16 M-C2E-B25 M-C2E-B40 M-C2E-B63 M-C2E-C10 M-C2E-C10 M-C2E-C16 M-C2E-C25 – – – – – – – – – – – – – – – M-D8E-B40 M-D8E-B63 M-D8E-C10 M-D8E-C10 M-D8E-C16 M-D8E-C25 – – – – – – – – – – – – – – – – – M-F8E-C10 M-F8E-C10 M-F8E-C16 M-F8E-C25 M-F8E-C25 M-F8E-C32 M-F8E-C45 – – – – – – – – – – – – – – – – – -CMN-2500 -CMN-2500 -CMN-4000 -CMN-4000 -CMN-6300 -CMN-6300 -CMN-9000 -CMN-6300 – -CMN-9000 – – – – Motor Dual 140M Motor Starter with Adjustable Current Circuit HP PWM Input Element Time Non-Time Circuit Rating Freq. Temp. Ratings Output Amps Delay Fuse Delay Fuse Breaker (3) Protector (4) Range (5)(6) ND HD kHz °C Amps kVA Cont. 1 Min. 3 Sec. Min. (1) Max. (2) Min. (1) Max. (2) Max. (8) Max. (8) Available Catalog Numbers - 140 . . . (7) 600 Volt AC Input Drive Catalog Number Frame Table A.E 600 Volt AC Input Protection Devices (See page 11 for Notes) PowerFlex 700 User Manual Update 9 20BF142 20BF119 20BF098 20BF082 20BF060 20BF052 5 45 – 5 55 – 5 75 – 5 90 – 6 110 – 6 132 – – 37.5 – 45 – 55 – 75 – 90 – 110 4 4 4 4 2 2 2 2 2 2 2 2 kW PWM Rating Freq. ND HD kHz 690 Volt AC Input Drive Catalog Number Frame 50 (9) 50 (9) 50 (9) 50 (9) 50 (9) 50 (9) 40 (9) 40 (9) 50 (9) 50 (9) 50 (9) 50 (9) Temp. °C 46.9 40.1 57.7 46.9 79.0 57.7 94.7 79.0 115 94.7 138 115 56.1 48.0 68.9 56.1 94.4 68.9 113 94.4 137 113 165 137 52 46 60 52 82 60 98 82 119 98 142 119 57 69 66 78 90 90 108 123 131 147 156 179 78 92 90 104 123 120 127 140 179 196 213 238 60 50 80 60 100 80 125 100 150 125 175 150 110 90 125 110 200 125 200 200 250 200 300 250 60 50 80 60 100 80 125 100 150 125 175 150 175 150 225 175 375 225 375 375 400 375 450 400 175 150 225 175 375 225 375 375 – – – – – – – – – – – – – – – – Motor Dual Circuit Input Element Time Non-Time Circuit (3) Protector (4) Ratings Output Amps Delay Fuse Delay Fuse Breaker (1) (2) (1) (2) (8) Amps kVA Cont. 1 Min. 3 Sec. Min. Max. Min. Max. Max. Max. (8) Table A.F 690 Volt AC Input Protection Devices (See page 11 for Notes) 10 PowerFlex 700 User Manual Update PowerFlex 700 User Manual Update 11 Notes: (1) Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping. (2) Maximum protection device size is the highest rated device that supplies drive protection. For US NEC, minimum size is 125% of motor FLA. Ratings shown are maximum. (3) Circuit Breaker - inverse time breaker. For US NEC, minimum size is 125% of motor FLA. Ratings shown are maximum. (4) Motor Circuit Protector - instantaneous trip circuit breaker. For US NEC minimum size is 125% of motor FLA. Ratings shown are maximum. (5) Bulletin 140M with adjustable current range should have the current trip set to the minimum range that the device will not trip. (6) Manual Self-Protected (Type E) Combination Motor Controller, UL listed for 208 Wye or Delta, 240 Wye or Delta, 480Y/277 or 600Y/ 347. Not UL listed for use on 480V or 600V Delta/Delta systems. (7) The AIC ratings of the Bulletin 140M Motor Protector may vary. See publication 140M-SG001B-EN-P. (8) Maximum allowable rating by US NEC. Exact size must be chosen for each installation. (9) UL Type 12/IP54 (flange mount) heatsink ambient temperature rating is 40° C/ambient of unprotected drive portion (inside enclosure) is 55° C. The ambient temperature for the UL Type 12/ IP54 Standalone drives is 40° C. 12 PowerFlex 700 User Manual Update Table A.G 540 Volt DC Input Protection Devices Frame Drive Catalog Number kW DC Input Rating Ratings ND HD Amps kW Output Amps Cont. 1 Min. 3 Sec. Fuse Bussmann Style Fuse 540 Volt DC Input 20BC1P3 (2) 20BC2P1 (2) 20BC3P5 (2) 20BC5P0 (2) 20BC8P7 (2) 20BC011 (2) 20BC015 (2) 20BC022 (2) 20BC030 (2) 20BC037 (2) 20BC043 (2) 20BC056 (2) 20BC072 (2) 20BC085 (2) 1 1 1 1 1 1 1 1 2 2 3 3 3 4 20BH105 (1)(2) 5 20BH125 (1)(2) 5 20BH140 (1)(2) 6 20BH170 (1)(2) 6 20BH205 (1) (2) (1)(2) 6 0.37 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 – 55 – 55 – 75 – 90 – 110 – 0.25 0.55 0.75 1.5 3.0 4 5.5 7.5 11 15 18.5 22 30 – 37 – 45 – 45 – 55 – 75 – 90 1.3 2.1 3.7 5.3 9.3 12.6 16.8 24 33.2 40.9 47.5 61.9 80.5 95.1 80.5 117.4 95.1 139.8 91.9 158.4 117.4 192.4 158.4 232 192.4 0.7 1.1 2.0 2.9 5.0 6.8 9.1 13 17.9 22.1 25.7 33.4 43.5 51.3 43.5 63.4 51.3 75.5 63.7 85.6 63.4 103.9 85.6 125.3 103.9 1.3 2.1 3.5 5.0 8.7 11.5 15.4 22 30 37 43 56 72 85 72 105 85 125 96 140 105 170 140 205 170 1.4 2.4 4.5 5.5 9.9 13 17.2 24.2 33 45 56 64 84 94 108 116 128 138 144 154 158 187 210 220 255 1.9 3.2 6.0 7.5 13.2 17.4 23.1 33 45 60 74 86 112 128 144 158 170 163 168 190 190 255 280 289 313 3 6 8 10 20 25 30 45 60 80 90 110 150 200 150 200 200 225 150 300 200 350 300 400 350 BUSSMANN_JKS-3 BUSSMANN_JKS-6 BUSSMANN_JKS-8 BUSSMANN_JKS-10 BUSSMANN_JKS-20 BUSSMANN_JKS-25 BUSSMANN_JKS-30 BUSSMANN_JKS-45 BUSSMANN_JKS-60 BUSSMANN_JKS-80 BUSSMANN_JKS-90 BUSSMANN_JKS-110 BUSSMANN_JKS-150 BUSSMANN_JKS-200 BUSSMANN_JKS-150 BUSSMANN_JKS-200 BUSSMANN_JKS-200 BUSSMANN_JKS-225 BUSSMANN_JKS-300 BUSSMANN_JKS-200 BUSSMANN_JKS-350 BUSSMANN_JKS-300 BUSSMANN_JKS-400 BUSSMANN_JKS-350 Also applies to “P” voltage class. UL Type 12/IP54 (flange mount) heatsink ambient temperature rating is 40° C/ambient of unprotected drive portion (inside enclosure) is 55° C. The ambient temperature for the UL Type 12/IP54 Standalone drives is 40° C. PowerFlex 700 User Manual Update 13 Drive Catalog Number Frame Table A.H 650 Volt DC Input Protection Devices kW Rating ND HD DC Input Ratings Amps kW Output Amps Cont. 1 Min. 3 Sec. Fuse Bussmann Style Fuse 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 – 75 – 100 – 125 – 150 – 1.0 1.9 3.0 4.5 8.1 11.1 14.7 23.3 28.9 36.4 42.9 55.7 69.7 84.5 67.9 105.3 84.5 137.1 105.3 171.2 137.1 204.1 171.2 1.1 2.1 3.4 5.0 8.0 11 14 22 27 34 40 52 65 77 65 96 77 125 96 156 125 180 156 BUSSMANN_JKS-6 BUSSMANN_JKS-6 BUSSMANN_JKS-6 BUSSMANN_JKS-10 BUSSMANN_JKS-15 BUSSMANN_JKS-20 BUSSMANN_JKS-30 BUSSMANN_JKS-45 BUSSMANN_JKS-60 BUSSMANN_JKS-70 BUSSMANN_JKS-80 BUSSMANN_JKS-100 BUSSMANN_JKS-150 BUSSMANN_JKS-150 BUSSMANN_JKS-150 BUSSMANN_JKS-200 BUSSMANN_JKS-150 BUSSMANN_JKS-250 BUSSMANN_JKS-200 BUSSMANN_JKS-300 BUSSMANN_JKS-250 BUSSMANN_JKS-400 BUSSMANN_JKS-300 650 Volt DC Input 20BD1P1 (2) 20BD2P1 (2) 20BD3P4 (2) 20BD5P0 (2) 20BD8P0 (2) 20BD011 (2) 20BD014 (2) 20BD022 (2) 20BD027 (2) 20BD034 (2) 20BD040 (2) 20BD052 (2) 20BD065 (2) 20BD077 (2) 0 0 0 0 0 0 1 1 2 2 3 3 3 4 20BR096 (1)(2) 5 20BR125 (1)(2) 5 20BR156 (1)(2) 6 20BR180 (1)(2) 6 (1) (2) 0.33 0.75 1.5 2 3 5 7.5 10 15 20 25 30 40 – 50 – 60 – 75 – 100 – 125 0.6 1.2 2.0 2.9 5.2 7.2 9.5 15.1 18.8 23.6 27.8 36.1 45.4 54.7 45.4 68.3 54.7 88.9 68.3 110.9 88.9 132.2 110.9 1.2 2.4 4.5 5.5 8.8 12.1 16.5 24.2 33 40.5 51 60 78 85 98 106 116 138 144 172 188 198 234 1.6 3.2 6.0 7.5 12 16.5 22 33 44 54 68 80 104 116 130 144 154 163 168 234 250 270 312 6 6 6 10 15 20 30 45 60 70 80 100 150 150 150 200 150 250 200 300 250 400 300 Also applies to “J” voltage class. UL Type 12/IP54 (flange mount) heatsink ambient temperature rating is 40° C/ambient of unprotected drive portion (inside enclosure) is 55° C. The ambient temperature for the UL Type 12/IP54 Standalone drives is 40° C. www.rockwellautomation.com Corporate Headquarters Rockwell Automation, 777 East Wisconsin Avenue, Suite 1400, Milwaukee, WI, 53202-5302 USA, Tel: (1) 414.212.5200, Fax: (1) 414.212.5201 Headquarters for Allen-Bradley Products, Rockwell Software Products and Global Manufacturing Solutions Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe/Middle East/Africa: Rockwell Automation SA/NV, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 Headquarters for Dodge and Reliance Electric Products Americas: Rockwell Automation, 6040 Ponders Court, Greenville, SC 29615-4617 USA, Tel: (1) 864.297.4800, Fax: (1) 864.281.2433 Europe/Middle East/Africa: Rockwell Automation, Herman-Heinrich-Gossen-Strasse 3, 50858 Köln, Germany, Tel: 49 (0) 2234 379410, Fax: 49 (0) 2234 3794164 Asia Pacific: Rockwell Automation, 55 Newton Road, #11-01/02 Revenue House, Singapore 307987, Tel: (65) 6356-9077, Fax: (65) 6356-9011 U.S. Allen-Bradley Drives Technical Support Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: [email protected], Online: www.ab.com/support/abdrives Publication 20B-DU008B-EN-P – September, 2005 Supersedes 20B-DU008A-EN-P – May, 2005 P/N 375173-C02 Copyright © 2005 Rockwell Automation, Inc. All rights reserved. Printed in USA.