Download Service Manual, 5ERKM (TP
Transcript
5.4 Stator The stator consists of a series of coils of wire laid in a laminated steel frame. The stator leads supply voltage to the AC load and exciter regulator. See Figure 5-7 for coil lead description. Stator Leads Description 1--2 Output coil 3--4 Output coil 33--44 Control wires from 3 and 4 55--33 Voltage regulator power source B1--B2 Controller power source Figure 5-7 Stator Coil Lead Description Before testing the stator, inspect it for heat discoloration and visible damage to the exposed coil windings and varnished areas of the frame laminations. Be sure the stator is securely fastened in the stator housing. The stator produces electrical output (AC) as the magnetized main field rotates within the stator windings. Test the condition of the stator according to the following procedure. Leads 1, 2, 3, and 4 are the generator output leads. Leads 33, 44, and 55 are the voltage regulator supply and sensing leads. The output of leads B1 and B2 is the control voltage for the controller. Stator Test Procedure: 1. Place the generator start/stop switch in the STOP position. Note: When taking an ohmmeter reading using lead 55, make the connection prior to the in-line fuse. 5. Check the cold resistance of the stator windings by connecting the meter leads to the stator leads 1-4, 2-5, 3-6, etc. See Section 1, Specifications, for the stator resistance values. 6. Perform a megohmmeter test on the stator as described in step 7. Note: Consider the stator functional if the resistance reading (continuity) is low and there is no evidence of shorted windings (heat discoloration). Note: The stator resistance varies directly with increased temperature. If the stator readings vary considerably during the previous checks, repair or replace the stator. 7. Check the stator for a grounded condition using a megohmmeter. Apply 500 volts DC to any stator lead from each winding and the stator frame. Follow the instructions of the megohmmeter manufacturer when performing this test. Repeat the test on the other leads until all of the stator windings have been tested. A reading of approximately 1.5 megohms and higher indicates the stator is functional. A reading of less than approximately 1.5 megohms indicates deterioration of the winding insulation and possible current flow to ground; if so, replace the stator. Between Leads Continuity 1 and 2 Yes 2. Disconnect the generator set engine starting battery, negative (--) lead first. 3 and 4 Yes 55 and 66 Yes B1 and B2 Yes 1 and 3, 4, 33, 44, 55 No 1 and 55, B1 and B2 No 3. Check the generator output lead connections. See Section 8, Reconnection and Wiring Diagrams. 4. Disconnect all of the stator leads to isolate the windings. To check the stator continuity, set the ohmmeter on the R x 1 scale. Check the stator continuity by connecting the meter leads to the stator leads as shown in Figure 5-8. Perform the stator tests on all of the stator windings. 20 Section 5 Generator Troubleshooting 4 and B1 and B2 No 55 and B1 and B2 No Any stator lead and ground No Figure 5-8 Stator Continuity TP-6079 3/00