Transcript
USER GUIDE HDH 3 (8) ML-SER menu ML-SER menu opens by pressing the M button. The values can be changed with the ”+” and ”-” buttons. The menu is device-specific and the content depends on the device and installed options. Measurement 900 CO2ppm M Modbus menu OK OK COMMUNICATIONS M MODBUS ID 9.6 Baud rate (k) Modbus address [OFF / 1…247] Modbus speed [9.6 / 19.2 / 38.4] OK Calibration menu OK 1 Modbus ID OK OK On ABC-Logic Offset: CO2ppm CO2 tuning [±200 ppm] M Parity bit [None / Even / Odd] OK 0 Modbus ID CALIBRATION OK n Parity 0.0 Offset: °C ABCLogic calibration [On / Off] OK 0 Offset: %RH Temperature measurement tuning [±3,0 °C] Humidity measurement tuning [±5 %RH] OK Controller menu Cont OFF CONTROLLER +/- M OK Cont CO2 OK PI Modbus ID Control mode Control method [PI / P] +/- OK +/- OK OK 300 Integr. time s 700 CO2 Setpoint Integration time [50...5000 s] CO2 set point [400...2000 ppm] OK 500 CO2 Propor. band CO2 proportional band [100...2000] P Control mode Cont TEMPERATURE OK OK PI Modbus ID Control mode Control method [PI / P] +/- OK +/- OK 300 Integr. time s OK 21.0 °C Setpoint Integration time [50...5000 s] OK 2.0 °C Propor. band °C set point [18...26 °C] ° C proportional band [1,0...32,0] P Control mode Cont HUMIDITY OK OK PI Modbus ID Control mode +/- Control method [PI / P] OK P Control mode +/- OK Cont MAXIMUM CTRL OK 300 Integr. time s Integration time [50...5000 s] OK PI Modbus ID Control mode Control method [PI / P] +/- OK OK 50 %RH Setpoint %RH set point [0...100 %] OK OK 50 %RH Propor. band %RH proportional band [10...100] OK 300 Integr. time s 700 CO2 Setpoint Integration time [50...5000 s] CO2 set point [400...2000 ppm] OK 500 CO2 Propor. band CO2 proportional band [100...2000] P Control mode OK 21.0 °C Setpoint °C set point [18...26 °C] OK Potentiometer menu POTENTIOMETER OK OK 1100 ID Modbus 5 Hysteresis % Relay ON RELAY Relay switching point [400...2000 ppm] OK Hysteresis [0...100 % from range] OK 750 YELLOW AL3 5s OK 1.0.0 ID Modbus VERSION INFO OK M Keltakalliontie 18, 48770 Kotka FINLAND Software version OK 1250 RED Yellow indicator light illumination point [400...2000 ppm] M Produal Oy %RH proportional band [10...100] Y4 M Info menu %RH set point [0...100 %] OK 50 %RH Propor. band OK OK AL3 menu ° C proportional band [1,0...32,0] 50 %RH Setpoint Potentiometer output [OFF / Y3 / Y4] M Relay menu OK OK 2.0 °C Propor. band no RESET Red indicator light illumination point [400...2000 ppm] OK Reset to factory settings [no / yes] Tel: +358-10-219 9100 / Fax: +358-5-230 9210 Information is subject to change without prior notice. [email protected] www.produal.com