Download User's Manual - Support
Transcript
Output Specifications OR, ERROR, RUN, ENABLE, GATE, DO0 to DO15 signals Mode NPN PNP Output voltage 12 to 24 VDC ±10% 12 to 24 VDC ±10% Load current 45 mA max. 45 mA max. ON residual voltage 2 V max. 2 V max. OFF leakage current 0.2 mA max. 0.2 mA max. Internal circuit diagram Respective terminal Load COMOUT Load COMOUT Respective terminal STGOUT 0 to 1 signals Mode NPN PNP Output voltage 12 to 24 VDC ±10% 12 to 24 VDC ±10% Load current 45 mA max. 45 mA max. ON residual voltage 2 V max. 2 V max. OFF leakage current 0.2 mA max. 0.2 mA max. Internal circuit diagram COMOUT COMIN 6 PARALLEL INTERFACE Respective terminal Load Load Respective terminal COMOUT COMIN Important Connect a load that matches the output specifications. Otherwise, a short-circuit may occur, which will cause the Controller to break down. ZFX-C User’s Manual Internal Specifications 161