Download IBM POWERPC 750GL User's Manual
Transcript
User’s Manual IBM PowerPC 750GX and 750GL RISC Microprocessor Little Endian Misaligned Accesses The 750GX supports misaligned single register load-and-store accesses in little-endian mode without causing an alignment exception. However, execution of a load/store multiple or string instruction causes an alignment exception. Self-Modifying Code When a processor modifies a memory location that might be contained in the instruction cache, software must ensure that memory updates are visible to the instruction-fetching mechanism. This can be achieved by the following instruction sequence: dcbst sync icbi isync # update memory # wait for update # remove (invalidate) copy in instruction cache # remove copy in own instruction buffer These operations are required because the data cache is a write-back cache. Since instruction fetching bypasses the data cache, changes to items in the data cache cannot be reflected in memory until the fetch operations complete. Special care must be taken to avoid coherency paradoxes in systems that implement unified secondary caches, and designers should carefully follow the guidelines for maintaining cache coherency that are provided in the VEA, and discussed in Chapter 5, “Cache Model and Memory Coherency,” in the PowerPC Microprocessor Family: The Programming Environments Manual. Because the 750GX does not broadcast the M bit for instruction fetches, external caches are subject to coherency paradoxes. Integer Load-and-Store Address Generation Integer load-and-store operations generate effective addresses using register indirect with immediate index mode, register indirect with index mode, or register indirect mode. See Section 2.3.2.3 on page 90 for information about calculating effective addresses. Note that in some implementations, operations that are not naturally aligned might suffer performance degradation. See Section 4.5.6 on page 170 for additional information about load-and-store address alignment exceptions. Integer Load Instructions For integer load instructions, the byte, half word, or word addressed by the EA is loaded into rD. Many integer load instructions have an update form, in which rA is updated with the generated effective address. For these forms, if rA ≠ 0 and rA ≠ rD (otherwise invalid), the EA is placed into rA and the memory element (byte, half word, or word) addressed by the EA is loaded into rD. Note that the PowerPC Architecture defines load with update instructions with operand rA = 0 or rA = rD as invalid forms. Table 2-18 summarizes the integer load instructions. Table 2-18. Integer Load Instructions (Page 1 of 2) Name Mnemonic Syntax Load Byte and Zero lbz rD,d(rA) Load Byte and Zero Indexed lbzx rD,rA,rB Load Byte and Zero with Update lbzu rD,d(rA) gx_02.fm.(1.2) March 27, 2006 Programming Model Page 99 of 377