Quick Tread - Stand Alone Flush Mounted Site Specifications 115/230v, 15 amp* 50/60 Hz 1 phƗ Power Requirements 90-150 PSI (6.2-10.3 bar) Air Supply Req. (IS Units) Approximate Air Consumption 25 SCFM @ 90 PSI (648 Lpm @ 6.2 bar) Substructure Specifications Refer to Form 6905-T Pedestal Location 36 - 96 in. (914 - 2438 mm) from QT1F Product Specifications 3500 lb. (1588 kg) per wheel Max. Wheel Weight 2 to 8 mph (3-13 km/h) Test Entry Speed Shipping Weight Stand-Alone Flush Mount Quick Tread Installation * Quick Check Cabinet 290 lbs (132 kg) Quick Check Drive Under Sensor 316 lbs (143 kg) Quick Tread 1723 lbs (455 kg) Amperage shown is minimal circuit rating. Ɨ Isolated ground recommended. OVERALL FOOTPRINT 12 ft. RECOMMENDED BAY WIDTH QUICK TREAD COMMUNICATION CABLES (UP TO 75 ft.) 51 in. 93 in. (7 ft. 9 in.) 4 in. OPTIONAL PEDESTAL LOCATION 22 ft. 5 in. TYPICAL Continued on Page 2 For inspection information visit: www.hunter.com/inspection For general inquiries visit: www.hunter.com or call 800 448-6848 For local contact visit: www.hunter.com/company/findrep.cfm Form 6897-T, 05-15a Copyright © 2015, Hunter Engineering Company Quick Tread - Stand Alone Flush Mounted QUICK CHECK DIMENSIONS 67 1/4 in. (5 ft. 7 1/4 in.) 32 in. 23 1/2 in. QUICK TREAD DIMENSIONS PEDESTAL 26 in. 5 in. 36 in. 26 in. 14 7/8 in. 51 in. 96 in. (8 ft.) is the maximum distance between the middle of the pedestal and nearest edge of Quick Tread. Any further will reduce max vehicle test entry speed. 34 1/2 in. 17 3/8 in. 5 in. 36 to 96 in. (3 ft. to 8 ft.) 93 in. (7 ft. 9 in.) PIT & CONDUIT SPECIFICATIONS END VIEW SIDE VIEW QUICK TREAD: HUNTER SUPPLIED Quick Tread’s 3 in. underground conduit must be routed to the pedestal according to local codes. The pedestal can be placed on either side. Exact placement of conduit will vary. Refer to Form 6905-T. QUICK TREAD SUB-STRUCTURE: CONTRACTOR SUPPLIED 93 in. 51 in. BAY FLOOR 8 in. 12 in. (min.) 46 1/2 in. 88 in. Form 6897-T, 05-15a Copyright © 2015, Hunter Engineering Company