Download Hunter Engineering Quick Tread Specification Sheet

Transcript
Quick Tread - Stand Alone
Flush Mounted
Site Specifications
115/230v, 15 amp* 50/60 Hz 1 phƗ
Power Requirements
90-150 PSI (6.2-10.3 bar)
Air Supply Req. (IS Units)
Approximate Air
Consumption
25 SCFM @ 90 PSI
(648 Lpm @ 6.2 bar)
Substructure Specifications
Refer to Form 6905-T
Pedestal Location
36 - 96 in. (914 - 2438 mm) from QT1F
Product Specifications
3500 lb. (1588 kg) per wheel
Max. Wheel Weight
2 to 8 mph (3-13 km/h)
Test Entry Speed
Shipping Weight
Stand-Alone Flush Mount Quick
Tread Installation
*
Quick Check Cabinet
290 lbs (132 kg)
Quick Check Drive Under
Sensor
316 lbs (143 kg)
Quick Tread
1723 lbs (455 kg)
Amperage shown is minimal circuit rating.
Ɨ
Isolated ground recommended.
OVERALL FOOTPRINT
12 ft.
RECOMMENDED
BAY WIDTH
QUICK TREAD COMMUNICATION CABLES (UP TO 75 ft.)
51 in.
93 in.
(7 ft. 9 in.)
4 in.
OPTIONAL
PEDESTAL
LOCATION
22 ft. 5 in.
TYPICAL
Continued on Page 2
For inspection information visit:
www.hunter.com/inspection
For general inquiries visit:
www.hunter.com
or call
800 448-6848
For local contact visit:
www.hunter.com/company/findrep.cfm
Form 6897-T, 05-15a
Copyright © 2015, Hunter Engineering Company
Quick Tread - Stand Alone
Flush Mounted
QUICK CHECK DIMENSIONS
67 1/4 in.
(5 ft. 7 1/4 in.)
32 in.
23 1/2 in.
QUICK TREAD DIMENSIONS
PEDESTAL
26 in.
5 in. 36 in.
26 in.
14 7/8 in.
51 in.
96 in. (8 ft.) is the
maximum distance
between the middle of the
pedestal and nearest edge
of Quick Tread. Any
further will reduce max
vehicle test entry speed.
34 1/2 in.
17 3/8 in.
5 in.
36 to 96 in.
(3 ft. to 8 ft.)
93 in.
(7 ft. 9 in.)
PIT & CONDUIT SPECIFICATIONS
END VIEW
SIDE VIEW
QUICK TREAD:
HUNTER
SUPPLIED
Quick Tread’s 3 in. underground
conduit must be routed to the
pedestal according to local codes.
The pedestal can be placed on
either side. Exact placement of
conduit will vary. Refer to Form
6905-T.
QUICK TREAD
SUB-STRUCTURE:
CONTRACTOR
SUPPLIED
93 in.
51 in.
BAY FLOOR
8 in.
12 in.
(min.)
46 1/2 in.
88 in.
Form 6897-T, 05-15a
Copyright © 2015, Hunter Engineering Company