Download HP 10Base-T Reference Guide

Transcript
A
Cables and Connectors
This appendix lists cables that have been tested and verified for use with the
HP Switching Hubs. It also includes minimum pin-out information so, if you
wish to use an unlisted cable, you can verify that the cables used in your
installation are correctly wired. Note that each pin-out does not necessarily
match the pin-out for the corresponding HP cable, but cables manufactured
to follow the minimum pin-out will function correctly.
Note
Incorrectly wired cabling is the most common cause of problems for LAN
communications. HP recommends that you work with a qualified LAN cable
installer for assistance with your cabling requirements.
Recommended Cables
Connection
Cable Type
Switching Hub to Switching
Hub
Extender Cable
Hub to end node connection
Twisted-pair
“straight-through”
cable
HP Product Number
5182-9814 71cm (12.5 inch)
5182-9869 31.8 cm ((28 inch)
92268A, B, C, D, or N (4-pair)
92214R, S, or T (25-pair)
To connect an HP Switching Hub to any Ethernet hub, use a “crossover” cable.
See that hub’s manual for crossover cable pin-outs.
You can contact your HP authorized dealer or call HP at 1-800-538-8787 to
order these parts.
A-1