Download Delta Tau BRICK CONTROLLER Reference Guide
Transcript
PMAC Quick Reference Guide Coordinate System IVariables Ix87 C.S. x Default Acceleration Time Ix88 Ix89 C.S. x Default S-Curve Time C.S. x Default Feedrate Ix90 C.S. x Feedrate Time Units Ix91 Ix92 Ix93 C.S. x Default Working Program Number C.S. x Move Blend Disable C.S. x Time Base Address Ix94 Ix95 Ix96 C.S. x Time Base Slew Rate C.S. x FeedHold Decel Rate C.S. x Circle Error Limit Ix98 Coordinate System x Maximum Feedrate I900, I905,.. I901, I906,.. I902, I907,.. I903, I908,.. I1000 I1001 I1003 I1004 I1005 Range Default Units 0 .. 8,388,607 0 (so Ix88 controls) 50 1000 Msec 0 .. 8,388,607 Positive floating point Positive floating point 0 .. 32,767 1000.0 0 0 .. 1 0 PMAC "X" See Ix93 table addresses 0 .. 8,388,607 1644 0 .. 8,388,607 1644 Positive floating 0 (function point disabled) Non-negative 0 floating-point Msec (User position units)/(feedrate time units) Msec Motion Program Numbers None Legal PMAC addresses 2-23msec/ servo cycle 2-23msec/servo cycle User length units None Encoder/Flag Setup IVariables Range Default Units Encoder 0 Decode Control 0 .. 15 7 None Encoder 0 Delay Filter Disable 0 .. 1 0 None Encoder 0 Capture Control 0 .. 15 1 None Encoder 0 Flag Select 0 .. 3 0 None MACRO Support I-Variables Range Default Units MACRO Node Auxiliary Register Enable MACRO Ring Check Period MACRO Type 1 Master/Slave Comm. Timeout MACRO Ring Error Shutdown Count MACRO Ring Sync Packet Shutdown Count 0 .. $FFFF (0 .. 65,535) 0 .. 255 0 .. 255 $0 None 0 0 Servo cycles Servo cycles 0 MACRO ring errors Appendix B – PMAC I-Variables Summary 0 .. 65,535 MACRO sync packets 79