Transcript
Lifecycle Controller Integration―Best Practices Specification Recommendation: Change the Telnet attributes prior to setting the SerialRedirection.Enable attribute. Or, if using input XML, have the Telnet attributes before the SerialRedirection.Enable attribute. 3.7 Never Unplug Hardware During Updates Users should not unplug any hardware during critical remote enablement (RE) updates. This may result in unexpected behaviors. As an example, unplugging a USB key during critical updates may cause a Red Screen of Death (RSOD). 3.8 Express Versus Enterprise iDRACs There are four levels of iDRAC licensing as follows: 1) Basic 2) Express (Monolithic) 3) Express for blades(Modular) 4) Enterprise One method of determining the level on a system is to perform an enumeration of the DCIM_iDRACCardView class. Example results are shown for reference. Monolithic: DCIM_iDRACCardView FQDD = iDRAC.Embedded.1-1 FirmwareVersion = 1.00.00 GUID = 3132334f-c0b7-3480-3510-00364c4c454 IPMIVersion = 2.0 InstanceID = iDRAC.Embedded.1-1#IDRACinfo LANEnabledState = 1 LastSystemInventoryTime = 20120302092309.000000+000 LastUpdateTime = 20120305233206.000000+000 Model = Enterprise PermanentMACAddress = 78:2b:cb:54:54:11 ProductDescription = This system component provides a complete set of remote management functions for Dell PowerEdge servers SOLEnabledState = 1 Modular: DCIM_iDRACCardView FQDD = iDRAC.Embedded.1-1 25