Download Avaya DECT Installation and Maintenance Manual

Transcript
Chapter 3 Configuring the DECT module
39
Confirming the DECT module
After the DECT module has been installed and the system has rebooted, you must identify the
module to the Business Communications Manager system.
Use this procedure to ensure the system recognizes the module type.
1
On the navigation tree, click the key beside Resources.
2
Click on Media Bay Modules.
3
Click on the Bus number for the DECT module.
4
Ensure that Programmed Bus Type is set to Trunk Module.
5
Click the key beside Modules on Bus.
6
Click on Module 1.
7
Ensure that Module Type is set to DECT.
8
If you made changes to any of the module settings, do the following, otherwise continue with
step 9:
a
Click on the DECT module Bus.
b
On the top menu, under Configuration, choose Disable.
c
On the message box, click OK.
d
On the top menu, under Configuration, choose Enable.
When the module is enabled, the State field reads: equipped.
9
At the bottom of the Resources list, click on the DECT heading.
10 Confirm the module name, or select the correct module.
Note: If the module does not immediately appear on the list, wait a few minutes and try
again.
This module type only appears when a DECT module is present on the system. If
the DIP switches are set incorrectly, the setting will appear, but the module will
show as unequipped.
Note: Companding law requirements.
The DECT module defaults to a-law. If your system requires the µ-law ISDN protocol,
refer to “Configuring the module for µ-law” on page 40 for instructions about resetting the
module.
DECT Installation and Maintenance Guide