Download American Standard Glendale 0625.000 User's Manual

Transcript
GLENDALE™
UNDERCOUNTER SINK
BARRIER FREE
VITREOUS CHINA
GLENDALE™ UNDER COUNTER SINK
•
•
•
•
Shell style pattern in bowl
Made from vitreous china
Unglazed rim for undermount
Front overflow with option of rear overflow
installation for Barrier Free
• Center drain outlet
• Supplied with mounting kit (047194-0070A)
and template
❏ 0625.000
464 x 381mm
(18-1/4" x 15")
Bowl Sizes:
406mm (16") wide
311mm (12-1/4") front to back
152mm (6") deep
A
FINISHED WALL
OR SPLASHBACK
B
51mm
(2) MIN.
76mm
(3)
610mm
(24)
OVERFLOW
76mm
(3)
Compliance Certifications Meets or Exceeds the
Following Specifications:
• ASME A112.19.2M for
Vitreous China Fixtures
41mm
(1-5/8)
EDGE OF
COUNTER
TOP
CUTOUT
381mm
(15)
180mm
(7-5/8)
C/L OF 864mm
OUTLET (34)
45°
C/L
MOUNTING
CLIP
(SEE DETAIL)
25mm
(1)
464mm
(18-1/4)
SEALING
COMPOUND
*343mm
* 273mm
BRASS
INSERT
MEETS THE AMERICANS WITH DISABILITIES ACT
GUIDELINES AND ANSI A117.1 ACCESSIBLE AND
USABLE BUILDINGS AND FACILITIES CHECK LOCAL CODES.
With overflow to the rear and countertop 864mm (34”)
from finished floor. Lavatory installed 51mm (2”) MIN.
from front edge of countertop. Countertop thickness to
be 25mm (1”) maximum.
19mm
(3/4) MIN.
LAVA
203mm
(8)
CLIP
MACH.
SCREW
1-1/4 O.D.
WASTE
1-1/4 O.D.
TAILPIECE
* See faucet section for additional models available
229mm
(9)
MIN.
DETAIL OF MOUNTING CLIP
(KIT No.47194.0070A)
16mm
(5/8)
SUPPLIES
AS REQ'D.
To Be Specified:
❏ Color:
❏ Faucet*:
❏ Faucet Finish:
❏ Supplies:
❏ 1-1/4" Trap:
152mm
(6)
MAX.
BARRIER FREE
CLEARANCE
19mm
(3/4)
(10-3/4)
787mm (31)
864mm (34)
DRAWING FOR
DIMENSIONAL
PURPOSES ONLY.
IT IS NOT AN EXACT
REPRESENTATION.
686mm
(27)
MIN.
COUNTERTOP
(BY OTHERS)
197mm
(7-3/4)
(13-1/2)
203mm
(8)
MIN.
FINISHED FLOOR
FITTING
A
B
CENTER-SET
27mm(1-1/16)
102mm(4)
SPREAD
32mm(1-1/4)
203mm(8)
REFER TO INSTRUCTIONS
PROVIDED WITH KIT FOR
ADDITIONAL INFORMATION
NOTES:
* DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TRAP ARE
SUGGESTED.
▼ UNDERCOUNTER MOUNTING KIT SUPPLIED WITH SINK.
FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED
SEPARATELY.
IN-FIELD ADJUSTMENT OF POP-UP ROD EXTENSION REQUIRED. PROVIDE A
2-1/2" OFF-SET BEND FOR PROPER OPERATION.
USE ENCLOSED TEMPLATE FOR COUNTERTOP CUTOUT.
SEALING COMPOUND SUPPLIED BY OTHERS.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of
tolerances established by ANSI Standard A112.19.2. These measurements are
subject to change or cancellation. No responsibility is assumed for use of
superseded or voided pages.
J47
© 2006 American Standard Inc.
Revised 5/06