Power Unit Components
The following table lists the power unit components.
Component Name
(Oracle ILOM CLI
Targets)
IPMI Type
Description
/SYS/PS[0-1]
FRU
Power supply FRU
/SYS/PS[0-1]/PRS
NT
Discrete
sensor
Power supply is present.
01h-ENTITY_PRESENT,
02h-ENTITY_ABSENT
/SYS/PS[0-1]/STA
TE
Discrete
sensor
Multistate, power supply
sensor type, per IPMI
Presence detected
Failure detected
Predictive failure
Power supply input lost
Power supply input lost
or out-of-range
Power supply input
out-of-range
Configuration error
/SYS/PS[0-1]/P_I
N
Power
sensor
Input power draw
Watts
/SYS/PS[0-1]/P_O
UT
Power
sensor
Output power
Watts
/SYS/PS[0-1]/V_I
N
Voltage
sensor
Input voltage
Volts
/SYS/PS[0-1]/V_1
2V
Voltage
sensor
12V rail voltage
Volts