Download MTP U R Series • Setup Guide
Transcript
NT: plete RTAfor the coomns, and O P m o M I tron.c instructi ng the .ex on ecti . www stallati e conn Go to uide, in s before er sourc g n ow p e user cificatio th to e t p s uc prod MTP U R Series • Setup Guide DELAY SIGNAL VID Y/C YUV SELECT RGB AUDIO RS-232 RGB R G B PEAKING LEVEL ADJUST This card provides quick start instructions for an experienced installer to set up and operate any of the MTP U R Series products. MTP U R RSA SEQ JMP1 Pre-installation — Jumper Settings JMP2 JMP3 Default settings (viewed from rear) The MTP U R has three jumpers located on the main board. JMP1 is RS-232 directional communication, and JMP2 and JMP3 are for vertical and horizontal sync (respectively). By default JMP1 is bidirectional; JMP2 and JMP3 are negative sync. Installation RJ-45 Connector Step 1 — Mounting Pins: 12345678 Turn off or disconnect all equipment power sources and mount the MTP U R as required. Step 2 — Connect Input Connect the RJ-45 cable from an MTP transmitter to the Input port on the MTP U R. Terminate the cable as shown on the right, using the same standard (A or B) at both ends. POWER 12V 0.5A MAX T568B Wire color 1 White-green White-orange 2 Green Orange 3 White-orange White-green 4 Blue 5 White-blue White-blue 6 Orange Green Blue 7 White-brown White-brown 8 Brown Brown Insert Twisted Pair Wires CAT 7 INPUT NOTE: T568A Wire color Pin If the input is labeled “CAT 7 Input”, only a CAT 7 cable should be used (that is, MTP C7 U R RSA SEQ model). Step 3 — Connect Outputs OUTPUTS Attach the applicable output cables (video, audio, and RS-232), depending on the MTP U R model used. R-Y Y Composite video output connector — Connect to the single female BNC connector (VID) . • S-video output connector — Connect to the 4-pin mini DIN connector (Y/C). • Component video (MTP U R RSA SEQ model only) — Connect to the three female BNC connectors (Y, R-Y, and B-Y). • High resolution video output connector — Connect to the 15-pin HD connector (RGB). Connected RS-232 Device Pins • RS-232 connector — Connect a serial communications port to the upper 3.5 mm, 5-pole captive screw connector for bidirectional RS-232 communication (as shown). Receive Transmit Ground • Audio connector (MTP U R RSA SEQ and MTP U R A models only) — Connect a suitable audio device to the lower 5-pole captive screw connector for mono audio output (as shown). NO GROUND. Unbalanced Output Mono output 1+ Mono output 1Sleeve(s) Mono output 2+ Mono output 2- Tx Rx SPACE MONO AUDIO 1 2 Y/C RGB MONO AUDIO 1 2 Do not tin the wires! Sleeve(s) Mono output 2 MONO AUDIO 1 2 NO GROUND. B-Y VID • Mono output 1 RS-232 MTP/HDMI U R Pins Tx Rx Gnd Spare Spare audio device Balanced Output Step 4 — Power Plug the included external 12 VDC power supply into the 2-pole captive screw connector. Wire the connector (see image a on the right). a POWER 12V xA MAX Smooth Ridges A A 3/16" (5 mm) Max. Grounding guidelines Extron MTP U R products can be adversely affected by electrostatic discharge (ESD) if they are not grounded correctly. To prevent malfunctions or product damage, an experienced installer can correctly ground an Extron MTP U R product in either of two ways: • Ground the power input port — Insert one end of the grounding wire to the negative or ground pin on the power input connector (see image a on the right). Tie the other end of the wire to an earth ground. • Ground the chassis — Use a connector hex nut as shown in image b the right. Tie the other end of the wire to an earth ground. If you have any questions about how to ground a product in a specific application, contact an Extron technical support specialist. Rear Panel SECTION A–A Power Supply Output Cord b Tie Wrap Ridges Earth Ground MTP U R Series • Setup Guide Step 5 — Input Signal Detection Check the displayed output is correct. The MTP U R detects the input signal format, indicated by the front panel LEDs (VID, Y/C, YUV, RGB), and differentiates between RS-232 and audio signals. The output is then made on the appropriate connector and all other outputs are muted. Step 6 — Peaking and Level Image sharpness is adjusted with the Peaking Control. Increased peaking compensates for mid- and high-frequency detail loss. Minimum setting (full counterclockwise) is zero peaking. RGB PEAKING LEVEL Image brightness is adjusted using the Level Control. View the image and adjust the control for the best image quality. MTP U R RS SEQ Step 7 — Skew Compensation Pair skew can be measured with test equipment or by viewing a crosshatch test pattern. The SEQ receivers have built-in skew compensation capabilities. Adjust the equalization as follows: SIGNAL A. Zero the skew delay for red, green, and blue by using a Tweeker or small screwdriver to press and hold the SelectVID Y/C button for 3 seconds. When the Red, Green, and Blue LED’s all go out, release the Select button. YUV B. Use UTP cable test equipment or examine the displayed image to determine which video signal (red, green, or blue) is shifted furthest to the right. DELAY RGB R SELECT RGB G B LEVEL MTP U R RS S C. Adjust the furthest left video signal towards the right by using a Tweeker or screwdriver to press and release the Select button until the LED for the left-shifted color lights. D. Slowly rotate the Adjust control clockwise until the shifted color is properly aligned. E. Repeat steps C and D to align the third color if needed. Extron MTPX 1616 Plus UT MTP Matrix Switcher Extron MTP U R RS S TP OU NO VID MT P U R DIO AU 2 MO 1 Universal Receiver RS Y/C B RO SET Tx Tx Tx 6 Tx 1 2 RJ 3 S 5 Extron MTP U R A 16 15 14 8 ON 3 UT 12 11 6 10 9 16 3 15 2 CT SELE 14 1 LOCAL INPUT B RG Rx 8 13 4 - 45 UT 12 S TP OU 11 10 B RG 3 2 NO 4 2 3 2 2 2 1 2 9 2 1 VID 1 1 S 1 UT 1 DIO UT INP 6 S UT 5 13 7 INP 4 TS TPU L OU CA B RG LO Tx Rx 7 TP 3 2 1 S UT L INP 1 CA LO RGB Tx Rx Rx Rx OU 4 REMOTE Tx Rx Rx Rx 12VA MA 0.5 RS-232/RS-422 7 - 232 L RS 5 CA LO 4 3 2 1 Tx ETHERNET RE 8 RG R WE PO X L ACT LINK NT CO MT INP P U R A MO 1 DIO AU 2 Universal Receiver Projector Y/C AU B RG R WE PO X 12VA MA 0.5 Extron MTP T SV A UT INP UTR INP L IDE O S-V UT TP OU A SV PT MT X 12V MA 0.5a MT P T 15 HD A K -PEA PRE ON UT TP OU DIO Transmitter AU OFF MO OR NIT Flat Panel Display R WE PO 12V MA .5A DING e /-R DVD-RW Precision RECOR Progressiv Cinema DVD X UT INP Extron MTP T 15HD A Transmitter PC Figure 1. Example of a Typical MTP U R Series Application Extron Headquarters +800.633.9876 Inside USA/Canada Only Extron USA - West Extron USA - East +1.714.491.1500+1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX Extron Europe +800.3987.6673 Inside Europe Only Extron Asia +800.7339.8766 Inside Asia Only +31.33.453.4040 +31.33.453.4050 FAX +65.6383.4400 +65.6383.4664 FAX Extron Japan +81.3.3511.7655 +81.3.3511.7656 FAX Extron China +4000.EXTRON +4000.398766 Inside China Only Extron Middle East +971.4.2991800 +971.4.2991880 FAX +86.21.3760.1568 +86.21.3760.1566 FAX © 2013 Extron Electronics All rights reserved. www.extron.com Extron Korea +82.2.3444.1571 +82.2.3444.1575 FAX PEAKIN ADJUST Extron India 1800.3070.3777 Inside India Only +91-80-3055.3777 +91 80 3055 3737 FAX 68-1367-50 Rev. B 01 13