Download Mitron MV1 User Guide

Transcript
d. You will get the firmware version as follow:
Firmware Version: V701240
2. Create a TA2S_ver.dat due to format of the file is Firmware File Prefix_
ver.dat and edit the content as follow:
Version: 701250 NAME:TA2S_
3. Change the new firmware voip.gz to TA2S_701250.gz
4. Put the TA2S_701250.gz and TA2S_ver.dat in Server
AUTO UPDATE PROCEDURES:
1. Every time when the VoIP Gateway reaches the Scheduling date and
time, it’ll check if there is an up to date firmware available on HTTP
Server and update the firmware automatically.
2. It takes around 3 minutes for updating the new firmware and the SIP
LED starts blinking while updating the firmware.
3. Once the SIP LED stop blinking, please power off and then power on
the VoIP Gateway to active the new firmware.
Be noted:
1. If the VoIP Gateway is powered off and passed the Next update time,
it'll not update the firmware after you power on the VoIP Gateway. It’ll
only update when the VoIP Gateway is power on and reaches Next
update time.
2. If you are on the phone and have a conversation to others by VoIP and
the Next update time is passing, it'll update the firmware immediately
after you hang up the phone.
Example 4: Firmware update automatically when reached the
Scheduling Date and Time
Auto Configuration Settings
Update via: TFTP
TFTP Server: 192.168.10.100
Check new Firmware: Scheduling
Automatic Update: Automatic (Scheduling)
Firmware File Prefix: TA2S