Download Mitron MV1 User Guide

Transcript
Firmware Version: V701240
2. Create a TA2S_ver.dat due to format of the file is Firmware File Prefix_
ver.dat and edit the content as follow:
Version: 701250 NAME:TA2S_
3. Change the new firmware voip.gz to TA2S_701250.gz
4. Put the TA2S_701250.gz and TA2S_ver.dat in Server
AUTO UPDATE PROCEDURES:
1. Every time when the VoIP Gateway reaches the Scheduling date and
time, it’ll check if there is an up to date firmware available on FTP
Server and update the firmware automatically.
2. It takes around 3 minutes for updating the new firmware and the SIP
LED starts blinking while updating the firmware.
3. Once the SIP LED stop blinking and the VoIP Gateway will reboot itself
to active the new firmware.
Be noted:
1. If the VoIP Gateway is powered off and passed the Next update time,
it'll not update the firmware after you power on the VoIP Gateway. It’ll
only update when the VoIP Gateway is power on and reaches Next
update time.
2. If you are on the phone and have a conversation to others by VoIP and
the Next update time is passing, it'll update the firmware immediately
after you hang up the phone.
5. IVR Interface for VoIP Gateway
You can use the PSTN phone to configure the VoIP Gateway. Please follow
the instruction to configure your VoIP Gateway.
Group
IVR Action
IVR Menu
Choice
Parameter(s)
Function
Reboot
#195#
None
Function
Factory Reset
#198#
None
Notes:
After you hear “Option Successful,” hang-up. T
system will reboot automatically.
How to:
a. Dial #190# and then hang up the phone
b. Dial #195# and then hang up the phone
c. The VoIP Gateway will reboot after 5 second
System will automatically Reboot. WARNING: A
“User-Changeable” NONDEFAULT SETTINGS
WILL BE LOST! This will include network and
service provider data.