Download Monogram ZDBT240 Specifications
Transcript
Design Guide THE INSTALLATION SPACE PRODUCT The wine CLEARANCES reserve fin" a l l 0 ° door When • Allow installed • Allow beverage clearance swing and on to allow 10" minimum for a flfll center is thctorv set in a corner: 4" rain. 90 ° door 34-1/2"-35" and swing. the clearance 1 10 ° door hinge racks on side to slide the Ira" the out. hinge side swing. 23-3/4" 10" Minimum to Wall 90° Door Swing 1-5/8" Handle and handle standoff iI i depth is 1-3/4" , L i! 23-5/8" I.,_J 23-3/4"f" The cutout depth should be 24" The cutout swing dimensions and access as a built-in • The wine installed The case and beverage between or side deep filler opening NOTE: The strip installed can will act door on as a spacer door include should a 1/2" be needed the The filler protrude the • Do not install where it will be subject to direct stmlight, heat or moistm'e. • These products are not designed to be stacked over the other. width panels. 1" beyond the Black or Stainless Specifications volt 15 or 20 amp 60Hz., required. An individual or circuit properly recessed breaker grotmded into the be located on tault power l)roperly supply 3-prong electrical back wall as shown. rear wall as shown. interrupter) SIDE-BY-SIDE branch is recommended. Install receptacle Electrical NOTE: is not a m ust OF] INSTALLATIONS storage cai)acit.v by installing beverage centers or wine reserves complete refl'eshment center, two Monogram Or, for together. install any two a of these 1_14"_10-1_/2" together. • A side-by-side installation opening. grotmded must No Options recommended. Increase • Products Steel Toekick trim operate requires kits fl'om at least 34-1/2"-35" a 47-1/2" required. separate, one • These products are shii)ped with a black toekick installed. An optional stainless steel toekick is also suI)plied with each product. For shiI)ping pm'I)oses, the stainless steel toekick is secured to the back o;c inside the unit. is grotmded in on the top and is unobstHtcted fi)r air circulation and proper access to the door. • Do not install these products where the temperature will go below 55°F (] 3°C) or above 90°F (32°C). wide hinge between swing. the location: • These products may be closed three sides as long as the front be cabinets. Additional wide 4" Minimum to Wall Choose cabinets, may cabinet must sm'rounding traits when \ door cabinets. center frameless panel ac!iacent of the (grotmd racks reserve and hn" a full fl'eestanding. side. circuit pull-out 24" strip • A 120 to the 110° .. allow in standard • If installing filler shown i)roperly 47-1/2" Min. receptacles. 3 [ _24 '' [