Design Guide
THE INSTALLATION
SPACE
PRODUCT
The
wine
CLEARANCES
reserve
fin" a l l 0 ° door
When
• Allow
installed
• Allow
beverage
clearance
swing
and
on
to allow
10" minimum
for a flfll
center
is thctorv
set
in a corner:
4" rain.
90 ° door
34-1/2"-35"
and
swing.
the
clearance
1 10 ° door
hinge
racks
on
side
to slide
the
Ira" the
out.
hinge
side
swing.
23-3/4"
10" Minimum
to Wall
90° Door Swing
1-5/8"
Handle and
handle standoff
iI
i
depth is 1-3/4"
,
L
i!
23-5/8"
I.,_J 23-3/4"f"
The cutout depth should be 24"
The
cutout
swing
dimensions
and
access
as a built-in
• The
wine
installed
The
case
and
beverage
between
or side
deep
filler
opening
NOTE:
The
strip
installed
can
will
act
door
on
as a spacer
door
include
should
a 1/2"
be needed
the
The
filler
protrude
the
• Do not install where it will be subject to direct
stmlight,
heat or moistm'e.
• These products
are not designed
to be stacked
over the other.
width
panels.
1" beyond
the
Black or Stainless
Specifications
volt
15 or 20 amp
60Hz.,
required.
An
individual
or circuit
properly
recessed
breaker
grotmded
into the
be located
on
tault
power
l)roperly
supply
3-prong
electrical
back wall as shown.
rear
wall as shown.
interrupter)
SIDE-BY-SIDE
branch
is recommended.
Install
receptacle
Electrical
NOTE:
is not
a
m ust
OF]
INSTALLATIONS
storage
cai)acit.v
by installing
beverage
centers
or wine
reserves
complete
refl'eshment
center,
two
Monogram
Or, for
together.
install
any
two
a
of these
1_14"_10-1_/2"
together.
• A side-by-side
installation
opening.
grotmded
must
No
Options
recommended.
Increase
• Products
Steel Toekick
trim
operate
requires
kits
fl'om
at least
34-1/2"-35"
a 47-1/2"
required.
separate,
one
• These products
are shii)ped
with a black toekick
installed.
An optional
stainless steel toekick is also
suI)plied with each product.
For shiI)ping
pm'I)oses,
the stainless steel toekick is secured
to the back
o;c inside the unit.
is
grotmded
in on the top and
is unobstHtcted
fi)r
air circulation
and proper
access to the door.
• Do not install these products where the temperature
will go below 55°F (] 3°C) or above 90°F (32°C).
wide
hinge
between
swing.
the location:
• These products
may be closed
three sides as long as the front
be
cabinets.
Additional
wide
4" Minimum
to Wall
Choose
cabinets,
may
cabinet
must
sm'rounding
traits
when
\
door
cabinets.
center
frameless
panel
ac!iacent
of the
(grotmd
racks
reserve
and
hn" a full
fl'eestanding.
side.
circuit
pull-out
24"
strip
• A 120
to the
110° ..
allow
in standard
• If installing
filler
shown
i)roperly
47-1/2" Min.
receptacles.
3