Download Mitsubishi Electric Q173HCPU Specifications
Transcript
4 POSITIONING DEDICATED SIGNALS (7) FIN signal (M4819+20n) ....................................... Command signal When a M-code is set in a servo program, transit to the next block does not execute until the FIN signal changes as follows: OFF ON OFF. Positioning to the next block begins after the FIN signal changes as above. It is effective, only when the FIN accelaration/deceleration is set and FIN signal wait function is selected. Virtual <K 1000> Point 1 2 3 4 CPSTART2 Axis 1 Axis 2 Speed FIN acceleration/ deceleration ABS-2 Axis 1, Axis 2, M-code ABS-2 Axis 1, Axis 2, M-code ABS-2 Axis 1, Axis 2, M-code ABS-2 Axis 1, Axis 2, CPEND Point 1 M-code 10000 100 200000 200000 10 300000 250000 11 350000 300000 12 400000 400000 WAIT 10 2 11 M-code outputting signal (M4019+20n) FIN signal (M4819+20n) Timing Chart for Operation Description 1. When the positioning of point 1 starts, M-code 10 is output and the M-code outputting signal turns on. 2. FIN signal turns on after performing required processing in the Motion SFC program. Transition to the next point does not execute until the FIN signal turns on. 3. When the FIN signal turns on, the M-code outputting signal turns off. 4. When the FIN signal turns off after the M-code outputting signal turns off, the positioning to the next point 2 starts. POINT (1) The FIN signal and M-code outputting signal are both signal for the FIN signal wait function. (2) The FIN signal and M-code outputting signal are valid only when FIN acceleration/deceleration is designated in the servo program. Otherwise, the FIN signal wait function is disabled, and the M-code outputting signal does not turn on. 4 - 37